Labor Pain Clinical Trial
Official title:
Fetal Life: Calibration, Noninferiority and Feasibility Studies for Smart-Device Based Uterine Activity Monitoring
This study will compare the performance of a contraction monitor (tocometer) device developed by Fetal Life with standard tocometer devices. The study aims to test a uterine contraction monitor that can be applied by the patient to her abdomen and connected to her smart device to detect the frequency and duration of uterine contractions. Phase 1 will collect data for calibration of the monitor and for a noninferiority study comparing the Fetal Life uterine contraction monitor (tocometer) with standard tocometry devices. Phase 2 will be a feasibility study in which patients will position the monitor, connect to the corresponding Fetal Life app and measure their own uterine contraction activity. The study's hypothesis is that after calibration, the new monitor will reliably detect at least 95% of the number and duration of contractions detected by the standard monitor, and that the device will perform comparably whether applied by the patient or by research staff.
Pregnant patients are counseled to monitor the frequency and duration of contractions in order to know when to come to the hospital for evaluation. Once a pregnant patient arrives at the hospital, contraction monitoring is important to help diagnose labor, which is defined as contractions with cervical change. In the hospital, a pressure-sensitive external contraction monitor or tocometer is positioned on the patient's abdomen with a belt to measure the frequency and length of her contractions. These tocometry monitors are impractical for home use because of their expense and because they create their output by connecting to bulky component devices. For these reasons reason, pregnant patients at home do not have access to automated tocometry monitoring. Patients are educated during prenatal care that contractions should be timed from the start of one contraction to the start of the next. These instructions can be difficult for patients to remember, and patients who are having painful contractions may prefer a more automated method for timing contractions. All methods currently available for home contraction tracking (on paper, using a smart device, or using one of many available smart device applications) require manual data entry either by the patient or her support partners. Patients are cautioned during pregnancy to maintain awareness of the development of uterine contractions. Early in pregnancy, patients are frequently counseled that infrequent, irregular contractions can be normal, but that frequent contractions occurring in a pattern can be a sign of preterm labor. As dehydration can cause the uterus to contract, preterm patients who notice contractions occurring in a pattern are often instructed to drink water, observe their contraction pattern, and come to the hospital if their contractions continue to occur every 15 minutes or more frequently following oral hydration. At term, patients are frequently counseled to come to the hospital when they are experiencing contractions that last about a minute, are occurring every five minutes, and have been at this duration and frequency for about an hour. Both preterm and at term, patients may have runs of contractions which resolve with time and hydration, but patients in both situations need to recognize when their contractions have reached the parameters recommended by their health care providers to seek medical attention. The new tocometer device tested in this study has significant cost savings in comparison to existing devices, and connects to a smart phone or tablet rather than a bulky receiver. The device will allow the patient to apply a monitor belt, connect it to her smart phone, and view a graphical representation of her contraction pattern with verbal descriptors that she can share with her health care team. Many patients have at least one visit to the hospital for evaluation of a contraction pattern which did not warrant this time and expense. This device may help patients to share a more accurate report of their symptoms with their prenatal care providers, potentially decreasing the stress of manual contraction tracking, improving the understanding of progress in early labor and decreasing unnecessary hospital visits. The device and app will not give the patient instructions on whether to come to the hospital, but will be used to help the patient understand if her uterine activity meets the parameters her prenatal care provider has given her to come in for evaluation. The Fetal Life device is constructed of smooth, latex-free plastic, is powered by a Lithium battery similar to a watch battery, and is held in place using a standard tocometry belt manufactured by General Electric. The investigators consider this to be a nonsignificant risk device. Phase 1 of this initial trial will allow a noninferiority comparison of the performance of this new contraction monitoring device with standard devices currently used in Labor and Delivery settings for monitoring duration and frequency of contractions. Phase 2 will assess feasibility for patient use. Procedure for Calibration and Noninferiority Phase (Phase 1): - Patients meeting inclusion criteria will be offered participation in the study by the Clinical Trials Unit (CTU) Staff - If the patient agrees to participate, CTU staff will obtain consent. - The patient will be assigned a participant number. - The Fetal Life tocometer will be applied to the patient's lower abdomen in addition to the standard tocometer used on Labor and Delivery and secured with the monitor belt by CTU staff - The Fetal Life tocometer will be paired the study iPad and output will be captured by CTU staff - The patient will be asked to cough in order to create a peak that synchronizes the graphic output of the Fetal Life tocometer and the standard tocometer - The patient will be monitored with the both the standard tocometer and the Fetal Life tocometer for 45-60 minutes - If the maternal or fetal status requires changes of maternal position during the trial, the Fetal Life monitor may be left in place, disconnected from the iPad or removed from the patient, whichever is least disruptive, so as not to interfere with the patient's obstetrical care in any way - CTU staff will document patient's age, parity, estimated gestational age and body mass index on a data collection sheet identified by participant number. No personal health information will be maintained on the data sheet. - If 45-60 minutes of monitoring is not completed, CTU staff will document the reason why - Patient will complete a brief survey on monitor comfort in comparison to the standard monitor - Image files from the standard tocometry fetal monitoring system will be exported for comparison with the output of the Fetal Life tocometer. - Fetal Life device will be sanitized with the antiviral, antibacterial wipes used routinely for sanitation of the standard tocometer devices before use with another patient. A new belt will be attached to the device for each subject. - For calibration, deidentified data from standard tocometer and the Fetal Life device will be reviewed by the team in the University of Louisville School of Engineering so that any needed adjustments can be made to the pressure transducer's sensitivity or graphic output - After calibration is completed (estimate 3 subjects needed), subjects will then be enrolled using the same protocol to collect data required for statistical analysis of non-inferiority Procedure for Feasibility Phase (Phase 2): - Patients meeting the inclusion criteria will be offered participation in the study by the Clinical Trials Unit (CTU) Staff - If the patient agrees to participate, CTU staff will obtain consent. - The patient will be assigned a participant number. - The patient will read the Fetal Life monitor instructions - Standard tocometry and fetal heart rate devices will be removed - The patient will apply the Fetal Life monitor using the positioning belt and will connect to the study iPad or lap top computer via Bluetooth - Fifteen minutes of monitoring will be captured via the iPad or lap top computer by CTU staff - During this time, the patient will note when she perceives the beginning and the end of her contractions; this will be documented the Clinical Trials Unit staff with time notations - Fetal Life monitor will be removed and the standard external fetal monitoring will resume - Patient will complete the patient survey ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT03539562 -
Therapeutic Rest to Delay Admission in Early Labor: A Prospective Study on Morphine Sleep
|
||
Withdrawn |
NCT04662450 -
Evaluation and Management of Parturients' Pain Intensity
|
N/A | |
Completed |
NCT02885350 -
Spinal or Epidural Fentanyl or Sufentanil for Labour Pain in Early Phase of the Labour
|
Phase 4 | |
Completed |
NCT02550262 -
Programmed Intermittent Epidural Bolus for Labor Analgesia During First Stage of Labor
|
N/A | |
Completed |
NCT01598506 -
Intrathecal Hydromorphone for Labor Analgesia
|
Phase 2 | |
Withdrawn |
NCT01636999 -
Comparing Sedara to Butorphanol in Early Labor
|
N/A | |
Completed |
NCT00987441 -
Epidural Labor Analgesia and Infant Neurobehavior
|
N/A | |
Completed |
NCT00755092 -
Effect of Doula in Nulliparas and Multiparas
|
N/A | |
Terminated |
NCT00787176 -
The Association Between Fluid Administration, Oxytocin Administration, and Fetal Heart Rate Changes
|
N/A | |
Recruiting |
NCT06036797 -
Efficacy and Safety of Hydromorphone-ropivacaine Versus Sufentanil-ropivacaine for Epidural Labor Analgesia
|
Phase 2 | |
Completed |
NCT05512065 -
Changes in Velocimetric Indices of Uterine and Umbilical Arteries Before and After Combined Spinal-epidural Analgesia in Laboring Women
|
N/A | |
Completed |
NCT05327088 -
Epidural Dexmedetomidine vs Nalbuphine for Labor Analgesia
|
Phase 2 | |
Completed |
NCT03103100 -
Comparing Bupivacaine, Lidocaine, and a Combination of Bupivacaine and Lidocaine for Labor Epidural Activation
|
Phase 3 | |
Recruiting |
NCT03623256 -
Comparison of Intrathecal Versus Epidural Fentanyl on Fetal Bradycardia in Labor Combined Spinal Epidural Analgesia
|
Phase 4 | |
Active, not recruiting |
NCT02271100 -
Assessment of the Use of Ultrasound for Epidural Catheter Placement and Comparison With Palpation Technique
|
N/A | |
Completed |
NCT02926469 -
Virtual Reality Analgesia in Labor: The VRAIL Pilot Study
|
N/A | |
Completed |
NCT03712735 -
Programmed Intermittent Epidural Bolus For Laboring Obstetrical Women
|
Phase 4 | |
Not yet recruiting |
NCT05565274 -
Outcome of Combined Tramadol and Paracetamol Versus Pentazocine as Labour Analgesia Among Parturients
|
N/A | |
Recruiting |
NCT01708668 -
The Effects of Intermittent Epidural Bolus on Fever During Labor Analgesia
|
N/A | |
Recruiting |
NCT02575677 -
Oxycodone in Treatment of Early Labour Pain Efficacy and Safety
|