Clinical Trials Logo

Clinical Trial Details — Status: Withdrawn

Administrative data

NCT number NCT03541967
Other study ID # MED-EL_ADHEAR_french_study1
Secondary ID
Status Withdrawn
Phase N/A
First received
Last updated
Start date July 15, 2018
Est. completion date July 15, 2019

Study information

Verified date June 2019
Source MED-EL Elektromedizinische Geräte GesmbH
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

Main objectives

- The first main objective is to evaluate the non-inferiority of the ADHEAR system compared to the PONTO 3 SUPERPOWER softband system in terms of average tonal gain.

- The second main objective of the study is to evaluate the superiority of the ADHEAR system compared to the PONTO 3 SUPERPOWER softband system in terms of comfort.

Secondary objectives

- Evaluate skin reactions with ADHEAR and PONTO 3 SUPER POWER on softband.

- Evaluate and compare perception in silence and noise with ADHEAR and PONTO 3 SUPER POWER on softband.

- Evaluate and compare the subjective auditory perception with ADHEAR and PONTO 3 SUPER POWER on softband.

- Evaluate the satisfaction and use of ADHEAR.


Description:

Introduction

Hearing loss, or deafness, is defined by the decrease in the perception of sounds. Conductive hearing loss is characterized by damage to the outer or middle ear. Its etiologies are congenital, malformative or acquired, sequelae of infectious or inflammatory processes (chronic otitis).

They cause a defect in the transmission of the sound towards the cochlea. Conductive hearing loss can be compensated by bone conduction hearing aids or middle ear implants.

Osteo-integrated bone conduction hearing aids (Baha, Ponto) have become the standard of care for patients with conductive hearing loss when an acoustic hearing aid can't be used.

These prostheses are percutaneous but for children the implantation of the osseointegrated abutment requires that the child has developed a sufficient bone thickness. In general, surgery is not possible before the age of 5 years. [Doshi et al. 2012].

They can be mounted on headband for testing [Haute Autorité de Santé, HAS 2008] or avoid surgery especially for very young children [e.g. Hol et al. 2005, Verhagen et al. 2008, Doshi et al. 2012, Doshi and McDermott 2015]. In this case the vibration of the bone is through the skin. But these systems on headband pose problems of maintenance and pressure on the skin.

Standard headband pre-tests are recommended by HAS [HAS 2014] and the bone anchored hearing aid is a gold standard for preoperative evaluation in children. It can be used to predict the potential benefit of the implanted system [Doshi et al. 2012]. Several transcutaneous systems are developed today [Reinfelt 2015, Doshi et al. 2012, Doshi and McDermott 2015] but they also require surgery and have an age limit before implantation.

MED-EL company has developed a new bone conduction system, ADHEAR, that does not require surgery and that transmits the sound by bone vibration through the skin. This system has the advantage of not applying pressure on the skin and has no age limit.

Objective of the study:

The objective of the study is to compare the new ADHEAR bone conduction hearing aid for children with conductive hearing loss to the commonly used reference system, the osteointegrated bone conduction prosthesis.

Comparator:

The comparator is the same in all the centers and will be the PONTO 3 SUPER POWER mounted on softband.

Hypotheses

The hypotheses are that patients with the ADHEAR bone conduction hearing aid:

- do not have a mean tonal gain lower than that obtained with a PONTO 3 SUPERPOWER mounted on a softband.

- have a gain in comfort compared to a PONTO 3 SUPERPOWER mounted on a sofband

Main objectives

- The first main objective is to evaluate the non-inferiority of the ADHEAR system compared to the PONTO 3 SUPERPOWER softband system in terms of average tonal gain.

- The second main objective of the study is to evaluate the superiority of the ADHEAR system compared to the PONTO 3 SUPERPOWER softband system in terms of comfort.

Secondary objectives

- Evaluate skin reactions with ADHEAR and PONTO 3 SUPER POWER on softband.

- Evaluate and compare perception in silence and noise with ADHEAR and PONTO 3 SUPER POWER on softband.

- Evaluate and compare the subjective auditory perception with ADHEAR and PONTO 3 SUPER POWER on softband.

- To evaluate the satisfaction and use of ADHEAR.

Plan of study

It is a prospective open multicenter randomized crossover study: measures will be done on the patient at the inclusion then by randomisation a first system (ADHEAR or PONTO 3 SUPER POWER on softband) will be fit to the patient and he will take it at home for 15 days. Afterwards, the patient will come back to the clinical center and measurements will be done with the first system. Then the patient will be fitted with the second system (PONTO 3 SUPER POWER on softband or ADHEAR) and will take it at home for 15 days. Afterwards, the patient will come back to the clinical center and measurements will be done with the second system.


Recruitment information / eligibility

Status Withdrawn
Enrollment 0
Est. completion date July 15, 2019
Est. primary completion date July 15, 2019
Accepts healthy volunteers No
Gender All
Age group 5 Years to 15 Years
Eligibility Inclusion Criteria:

- Age: between 5 and 15 years old.

- Child for whom a bone conduction prosthesis test is indicated

- conductive hearing loss: bone conduction = 10 dB Hearing Level (HL)

- Contralateral ear: air conduction = 30 dB HL at 500, 1000, 2000, 3000 and 4000Hz

- No test of conductive bone conduction hearing aid with softband in the 3 months preceding the study

- No associated disorders

- Child not already fitted with a bone conduction system

Exclusion Criteria:

Study Design


Intervention

Device:
ADHEAR and PONTO 3 SUPER POWER on softband hearing aids
Device: ADHEAR non-implantable bone conduction hearing aid Comparator: PONTO 3 SUPER POWER bone conduction hearing aid with softband

Locations

Country Name City State
n/a

Sponsors (1)

Lead Sponsor Collaborator
MED-EL Elektromedizinische Geräte GesmbH

Outcome

Type Measure Description Time frame Safety issue
Primary Average tonal gain (dB) The threshold of free-field tonal audiometry is measured in the free field with masking of the contralateral ear with and without the auditory system. The tonal gain is defined by the difference of the tonal threshold with / without the auditory system. The average tonal gain is defined by the average of the tonal gain at frequencies 500, 1000, 2000, 3000 and 4000 Hz. 15 days after fitting of the system and port at home
Primary Comfort Perceived comfort will be measured with a visual analogue scale (VAS) of 10 cm overall comfort. The VAS will have the following anchors:
10 = very comfortable; 8 = comfortable; 6 = comfortable enough; 4 = uncomfortable; 2 = very uncomfortable; 0 = not comfortable at all
15 days after fitting of the system and port at home
Secondary Skin reactions The measurement of cutaneous reactions with the auditory system will be done with a Holgers scale by the practitioner. Holgers scale:
0 = No irritation; 1 = Slight redness; 2 = Red and slightly moist tissue; 3= Reddish and moist; 4 = Removal of hearing aid system necessary R = Removal of hearing aid system for reasons not related to skin problems
15 days after fitting of the system and port at home
Secondary Bone conduction thresholds (dB Hearing Level (HL)) The air conduction threshold conduction is measured with a headphone at 250, 500, 1000, 2000, 3000 and 4000 Hz. The variation is defined by the difference of bone conduction threshold at each frequency at the inclusion and at the end of the inclusion. at the inclusion and 30 days after
Secondary Subjective measurement of auditory perception The subjective auditory perception will be measured by a self-questionnaire to be completed by the parents: the Speech, Spatial, and Qualities of Hearing Scale (SSQ) for Parents [Galvin and Noble 2013]. The parents have to answer questions about specific situations for their child with and without the hearing system.
SSQ items have VAS from 0 to 10 with integer anchors and qualitative anchors "not at all" for 0 and "perfectly" for 10.
Scores are calculated for three subscales:
on speech perception: 9 VAS
on spatial localization: 6 VAS
on the quality of hearing: 8 VAS
On each subscale the difference of score with and without the hearing system is calculated.
15 days after fitting of the system and port at home
Secondary Measurement of satisfaction and use of ADHEAR The satisfaction and use of ADHEAR will be measured by a specific MED-EL self-questionnaire. Twenty questions with various qualitative answers. The analysis is descriptive for each question. 15 days after fitting of the system and port at home
Secondary Air conduction threshold (dB HL) The air conduction threshold conduction is measured with a headphone at 250, 500, 1000, 2000, 3000, 4000 and 8000 Hz. The variation is defined by the difference of air conduction threshold at each frequency at the inclusion and at the end of the inclusion. at the inclusion and 30 days after
Secondary Vocal audiometry in silence Measure of the speech reception threshold (i.e. the speech intensity in dB Sound Pressure Level (SPL)) for 50% (SRT50) and 100% (SRT100) of comprehension of words (list of Boorsma) in free field (with masking of the contralateral ear) with and without the auditory system. The gain (dB) is defined by the difference of SRT with/without the auditory system. 15 days after fitting of the system and port at home
Secondary Vocal audiometry in noise Hirsch test in dichotic condition: signal = speech words (list of Boorsma) on the side of the auditory system ; noise = white noise at 65 dB Sound Pressure Level (SPL) in front of the patient (0°). Measure of the speech reception threshold (i.e. the speech intensity in dB SPL) for 50% (SRT50) and 100% (SRT100) of comprehension of words (list of Boorsma) in free field with and without the auditory system. The gain (dB) is defined by the difference of SRT with/without the auditory system. 15 days after fitting of the system and port at home
See also
  Status Clinical Trial Phase
Completed NCT03723161 - Evaluation of the Ponto Bone Anchored Hearing System in a Pediatric Atresia Population
Completed NCT04320407 - Osia CPT Code Study N/A
Active, not recruiting NCT01445977 - SoundBite Hearing System Long Term Multi Site Patient Use Study N/A
Completed NCT02304692 - Clinical Survey of Different Abutment Topologies N/A
Recruiting NCT00393159 - The Influence of The Ear Popper on Serous Otitis Media and on the Accompanying Conductive Hearing Loss in Children Phase 4
Recruiting NCT06164184 - Interest of the Cone Beam Scanner of Temporal Bones in the Analysis of Conductive Hearing Loss
Not yet recruiting NCT01967498 - Montelukast for Children With Chronic Otitis Media With Effusion (COME): A Double-blind, Placebo-controlled Study N/A
Active, not recruiting NCT05628285 - Evaluation of a Hearing Device for Transmitting Sound to the Inner Ear N/A
Completed NCT03374787 - Evaluation of Sound Processor for a Transcutaneous System N/A
Completed NCT02092610 - Long Term Stability, Survival and Tolerability of a (Novel) Baha® Implant System N/A
Completed NCT01671176 - Wide Diameter Bone Anchored Implant Study N/A
Completed NCT03086135 - Clinical Performance of a New Implant System for Bone Conduction Hearing N/A
Recruiting NCT01807559 - SoundBite Hearing System 24 Month Multi Site Patient Use Study N/A
Withdrawn NCT01264510 - Evaluation of the Effectiveness of Bone-anchored Hearing Aids (Baha) Phase 4
Recruiting NCT04803279 - Investigating Hearing With Ponto 3 SuperPower, a Bone Anchored Hearing Aid - Investigating Hear
Completed NCT03143257 - Ambispective Clinical Evaluation of Sophono™
Completed NCT02274129 - Clinical Survey of Oticon Medical Healing Cap N/A
Recruiting NCT03327194 - Use of ADHEAR, a Non-Implantable Bone Conduction Hearing System, in Children With Single Sided Deafness and/or Conductive Hearing Loss N/A
Completed NCT05000931 - Osia 2 Pediatric Expansion Study N/A
Completed NCT03746548 - Audiological Benefit and Quality of Life With Two Bone Conduction Systems: ADHEAR vs. Contact Mini N/A