Clinical Trials Logo

Clinical Trial Summary

To assess implant stability, implant loss, adverse skin reactions, and Quality of Life Benefit following implantation of the Ponto 4.5mm Wide Diameter implant. Secondary: to determine the feasibility of fitting the sound processor 3 weeks after surgical implantation, and to investigate if the type of skin reactions following implantation could be related to the demographic data of subjects and the type of surgical technique used


Clinical Trial Description

Bone-anchored hearing systems have been an amplification choice for conductive, mixed, and profound, unilateral, sensorineural hearing loss for over three decades. So far, about 75,000 patients worldwide have received this surgical intervention (bone-anchored hearing system), since its first successful implantation in 1977. In 2009, Oticon Medical, LLC launched its bone-anchored hearing system called Ponto. In just over two years, the Ponto has been successfully implanted in over 3,000 patients by leading otolaryngologists and neurotologists in 18 countries worldwide.

The Ponto implant has previously been available with a 3.75mm diameter and comes in two lengths: 3mm and 4mm. Anew Ponto implant that is 4.5mm wide in diameter is now available in both 3mm and 4mm lengths. This Wide Diameter implant is designed to maximize bone-to-implant contact area and enhance implant stability which can potentially allow loading of the sound processor as early as 3 weeks after surgery. The abutment screw incorporates external threads at the screw head to make it possible to connect a SmartPeg (Osstell, Goteborg, Sweden) for stability measurements. All Ponto implants have the same universal implant-abutment interface. Therefore, they are fully compatible with existing instruments and abutments. Two new countersinks have been developed for the new Ponto Wide Diameter implant. The drill size of the countersink is 3.80mm. It is marked with a "W" to separate them from existing drills. All products are CE-marked and cleared for the US market by the FDA.

Objectives The present study will attempt to show that the Ponto 4.5mm Wide Diameter implant has similar or better outcomes in terms of Quality of Life (QoL) benefit; implant extrusion and revision surgery when compared to the 3.75mm diameter implant. Secondary objectives to be studied will include adverse skin reactions, the feasibility of fitting the sound processor three weeks after surgical implantation, and investigation to see if the type of skin reactions observed following implantation could be related to the demographic data of subjects or the type of surgical technique used.

Study Design This study is a prospective, multicenter study of subjects' demographic and implant data. Subjects will be enrolled at two US sites.

Subject Population Twenty adult subjects 18 years or older will be included in the study from each participating partner site. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT01671176
Study type Interventional
Source Oticon Medical
Contact
Status Completed
Phase N/A
Start date May 2012
Completion date November 2014

See also
  Status Clinical Trial Phase
Completed NCT03723161 - Evaluation of the Ponto Bone Anchored Hearing System in a Pediatric Atresia Population
Completed NCT04320407 - Osia CPT Code Study N/A
Active, not recruiting NCT01445977 - SoundBite Hearing System Long Term Multi Site Patient Use Study N/A
Completed NCT02304692 - Clinical Survey of Different Abutment Topologies N/A
Recruiting NCT00393159 - The Influence of The Ear Popper on Serous Otitis Media and on the Accompanying Conductive Hearing Loss in Children Phase 4
Recruiting NCT06164184 - Interest of the Cone Beam Scanner of Temporal Bones in the Analysis of Conductive Hearing Loss
Not yet recruiting NCT01967498 - Montelukast for Children With Chronic Otitis Media With Effusion (COME): A Double-blind, Placebo-controlled Study N/A
Active, not recruiting NCT05628285 - Evaluation of a Hearing Device for Transmitting Sound to the Inner Ear N/A
Completed NCT03374787 - Evaluation of Sound Processor for a Transcutaneous System N/A
Completed NCT02092610 - Long Term Stability, Survival and Tolerability of a (Novel) Baha® Implant System N/A
Completed NCT03086135 - Clinical Performance of a New Implant System for Bone Conduction Hearing N/A
Recruiting NCT01807559 - SoundBite Hearing System 24 Month Multi Site Patient Use Study N/A
Withdrawn NCT01264510 - Evaluation of the Effectiveness of Bone-anchored Hearing Aids (Baha) Phase 4
Recruiting NCT04803279 - Investigating Hearing With Ponto 3 SuperPower, a Bone Anchored Hearing Aid - Investigating Hear
Completed NCT03143257 - Ambispective Clinical Evaluation of Sophono™
Completed NCT02274129 - Clinical Survey of Oticon Medical Healing Cap N/A
Withdrawn NCT03541967 - Comparison of a New Bone Conduction Hearing System to a Osteo-integrated Bone Conduction Hearing Aid on a Softband N/A
Recruiting NCT03327194 - Use of ADHEAR, a Non-Implantable Bone Conduction Hearing System, in Children With Single Sided Deafness and/or Conductive Hearing Loss N/A
Completed NCT05000931 - Osia 2 Pediatric Expansion Study N/A
Completed NCT03746548 - Audiological Benefit and Quality of Life With Two Bone Conduction Systems: ADHEAR vs. Contact Mini N/A