Clinical Trials Logo

Clinical Trial Summary

A better understanding of knee joint kinematics is important to explain the premature polyethylene wear failures within total knee arthroplasties (TKAs) and to help design a prosthesis that most closely approximates the normal knee. Previously, most experimental studies of knee kinematics have involved cadaveric, in vitro analyses, or have not tested the knee in a weight-bearing mode. Others have used exoskeletal linkages and skin markers that permit error due to undesired motions between markers and the underlying bone. More recently, fluoroscopy has been used to assess in vivo kinematics for subjects having a TKA. ConforMIS has attempted to follow a clearly different path than the major orthopaedic companies. They have chosen to offer patients a personalized knee implant based off of each patient's femoral and tibial bone geometry. The hypothesis is that these subjects will experience a more normal-like kinematic pattern, eliminating paradoxical anterior sliding during weight-bearing knee flexion. Therefore, the objective for this study is to analyze the in vivo kinematics for 25 patients implanted with a personalized ConforMIS TKA and 25 patients implanted with a traditional TKA design to determine if there are any kinematic differences between these TKA designs.


Clinical Trial Description

Each subject will be asked to perform five activities in one continuous sequence: (1) stand up from a chair, (2) walk up stairs, (3) walk down stairs, (4) level walking, and (5) a deep knee bend. Subjects will be video recorded from the waist down while performing the activities. The speed level of each trial will be based on the comfort level of the patient. The fluoroscopic images will be stored digitally for subsequent analysis on secure servers and workstations at the University of Tennessee. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT01882751
Study type Observational
Source Restor3D
Contact
Status Completed
Phase
Start date June 2013
Completion date August 2017

See also
  Status Clinical Trial Phase
Completed NCT02043132 - Tranexamic Acid in Reverse Total Shoulder Arthroplasty Phase 2/Phase 3
Recruiting NCT02255331 - Using MRI To Detect Soft Tissue Reactions And Implant Integration As Related To Implant Modularity
Completed NCT01442298 - A Comparison Between an Individual Low Tourniquet Pressure Versus a Standard Pressure During Total Knee Arthroplasty N/A
Completed NCT02774174 - The Evaluation of the METS™ Proximal Humeral System
Withdrawn NCT02054936 - Evaluation of Wound Drainage After Knee or Hip Arthroplasty Phase 4
Recruiting NCT01542580 - A Prospective, Clinical Investigation of the Vanguard 360 Revision Knee
Completed NCT02598700 - Correlation of Spinopelvic Parameters and Acetabular Cup Orientation
Completed NCT01820611 - Arcos Revision Stem: Evaluation of Clinical Performance
Completed NCT01514318 - Encore Revelation Hip Stem N/A
Completed NCT02124031 - Mexican Initiative of Patients With Osteoarthritis and Rheumatoid Arthritis (IMPACTAR) N/A
Completed NCT01373112 - Articulating Versus Static Antibiotic Loaded Spacers for the Treatment of Prosthetic Knee Infection N/A
Completed NCT01373099 - Study of Antibiotic Spacer Design to Treat Infection After Hip Replacement N/A