View clinical trials related to Colonic Polyps.
Filter by:The purpose of this study is to evaluate and compare the incomplete resection rates for small colon polyps less than or equal to 6 mm in size using two conventional polypectomy tools, jumbo cold biopsy forceps and cold snare.
Removal of polyps at colonoscopy reduces colon cancer. Snare polypectomy is the conventional method for removal however the snared area after removal can occasionally appear uneven raising the possibility that complete removal has not occurred. The significance of this irregularity has not be studied. This study aims to separately sample the irregular area and determine the constituents while recording how frequently this occurs during routine colonoscopy and polypectomy. We hypothesize that the irregular areas are submucosal tissue and do not represent polyp tissue left behind.
The investigators have recently become proficient in a new, and we believe more effective technique for polyp removal. Known as Endoscopic Submucosal Dissection (ESD). ESD involves removing the polyp in one piece. It is preferable to remove the polyp in one piece as it minimises the chance of leaving residual polyp tissue behind. There have also been recent studies overseas that have shown this new technique to be quite effective. In this study, half of the patients will receive the newly developed technique of polyp removal (ESD), while the other half will receive conventional Endoscopic Mucosal Resection (EMR) treatment. This study will allow us to show which technique results in lower recurrence rates and is more effective.
Patients will be randomised to have endoscopic clips applied to the Endoscopic Mucosal Resection (EMR) site following complete removal of the lesion, or will not receive clips and proceed with standard of care.
Although endoscopic colonic polypectomy has been an established procedure for two decades, the risk of bleeding is still higher after resecting of pedunculated polyps, because of the presence of a large artery in the stalk. Preventive methods such as endoloop and epinephrine injection have been proposed in the management of postpolypectomy bleeding in large colonic polyps. For prophylactic clip, there was no randomized controlled study assessing the efficacy in the prevention of postpolypectomy bleeding for the large pedunculated polyps. So the investigators designed a randomized controlled trial to confirm the efficacy of application of prophylactic clip in the prevention of postpolypectomy bleeding in large polyps.
This study is to evaluate the performance of Hemospray for the teatment of nonvariceal lower gastrointestinal bleeding.
The study hypothesis is whether digestion enzyme(Combizym) and intestinal flora drugs(Bifidobacteria) can decease recurrence rate of colon polyps
Summary Colorectal cancer (CRC) represents the second leading cause of cancer deaths in Spain (11,000 deaths per year). Screening of the population over 50 years of age with no significant history (intermediate risk) is recommended, but which screening method is best for promoting adherence in this type of patient has not been well established. There are currently two screening methods that are less invasive than conventional colonoscopy and seem to have higher sensitivity than the test for faecal occult blood (FOBT). These two methods are the colon capsule, which consists in ingesting a capsule that takes photographs of the colon, and virtual colonoscopy, which is a radiological technique. Objectives: 1. To demonstrate that virtual colonoscopy and colon capsule are effective CRC screening techniques in the intermediate risk population, with diagnostic rates comparable to conventional colonoscopy (concordance). 2. To compare the diagnostic rates of the colon capsule and virtual colonoscopy with respect to the size and characteristics of the lesions visualised. 3. To compare the participation rates for each screening strategy and identify the factors that influence participation (individual, family, and socioeconomic factors as well as those relating to the doctor).
Colorectal cancer is the second most common cancer in the world and the second leading cause of cancer-related mortality. Colorectal cancers arise from precursor adenomatous polyps in a well characterized adenoma to carcinoma progression. The removal of such precursor lesions reduces colorectal cancer mortality between 30 to 50%. Colonoscopy is used for detection of neoplastic polyps but significant miss rates of such lesions are reported. Methods to reduce spasm of the colon have been investigated to increase adenoma detection rates including the use of warm water irrigation and hyoscine butyl bromide. Carbon dioxide warmed to body temperature is postulated to have spasmolytic effects. Administration of warmed carbon dioxide during colonoscopy may improve polyp detection. Objective: In this study, colonoscopy using warmed carbon dioxide insufflation will be compared to standard room temperature air insufflation to see if there is a greater detection of polyps per patient. Methods: Patients undergoing colonoscopy for screening and surveillance indications will be included and randomized to receive either room temperature room air or warmed carbon dioxide (37 degrees Celsius). Endoscopists and patients will be blinded to the intervention. Data on indication, preparation, sedation, withdrawal time will be recorded. Polyp detection rate will be the primary outcome. Secondary outcomes will include adenoma detection rate and advanced lesion detection rates.
Colorectal cancer accounted for 142,570 new cancer cases and 51,370 cancer deaths in USA in 2010 and worldwide has become the third most common cancer and second leading cause of cancer related deaths. Colonic adenomatous polyps are known precursors of colorectal cancer and endoscopic removal of the polyps prevents development of colon cancer. Removal of such large polyps requires special endoscopic techniques-endoscopic mucosal resection (EMR) and endoscopic submucosal dissection (ESD), which are more technically difficult to perform, labor intensive, time consuming and carries higher risks of complications (bleeding, perforations, etc.). The purpose of this study is to determine the effectiveness and safety of the LumenR Retractor in performing EMR and ESD. It is hypothesized that the use of this modified colonic overtube will simplify colonoscopic removal of difficult polyps, decrease the time needed to complete the procedure and decrease the rate of complications post endoscopic removal of large and flat colonic.