Colonic Diseases Clinical Trial
Official title:
Evaluation of PillCam™ Colon 2 in Visualization of the Colon
NCT number | NCT01087528 |
Other study ID # | MA-202 |
Secondary ID | |
Status | Completed |
Phase | N/A |
First received | |
Last updated | |
Start date | July 2009 |
Est. completion date | May 2010 |
Verified date | September 2020 |
Source | Medtronic - MITG |
Contact | n/a |
Is FDA regulated | No |
Health authority | |
Study type | Interventional |
To evaluate the performance of PillCam COLON 2 in regards to detection of patients with polyps where colonoscopy is considered as the gold standard reference.
Status | Completed |
Enrollment | 51 |
Est. completion date | May 2010 |
Est. primary completion date | May 2010 |
Accepts healthy volunteers | No |
Gender | All |
Age group | 18 Years to 70 Years |
Eligibility | Inclusion criteria: - Subject is between the ages of 18-70 - Subject was referred to colonoscopy for at least one of the following reasons: - Colorectal cancer screening for age =60 - Clinical symptoms such as: rectal bleeding, hematochezia, melena, positive FOBT, recent change of bowel habits for age =50 - Positive findings in the colon (e.g. Polyp =10mm) - Personal history of significant polyps( =6mm )that were removed at least 3 years ago (3 years and above) Exclusion criteria - Age > 70 years - Subject has dysphagia or any swallowing disorder - Subject has congestive heart failure - Subject has known renal disease - Subject is not eligible for colon preparation due to the presence of underlying conditions based on the clinical judgment of the investigator - Subject has any allergy or other known contraindication to the medications used in the study - Subject has had prior abdominal surgery of the gastrointestinal tract other than uncomplicated procedures that would be unlikely to lead to bowel obstruction based on the clinical judgment of the investigator - Subject has a cardiac pacemaker or other implanted electro medical device. - Subject is expected to undergo MRI examination within 7 days after ingestion of the capsule. - Subject with any condition believed to have an increased risk for capsule retention such as Crohn's disease, intestinal tumors, radiation enteritis, incomplete colonoscopies due to obstructions or NSAID enteropathy, - Subject with gastrointestinal motility disorders - Subject has known delayed gastric emptying - Subject has any condition, which precludes compliance with study and/or device instructions. - Women who are either pregnant at the time of screening, or are of child-bearing potential and do not practice medically acceptable methods of contraception. - Subject suffers from life threatening conditions - Subject currently participating in another clinical study - Age>70 |
Country | Name | City | State |
---|---|---|---|
United States | Digestive Care, Inc. | Beavercreek | Ohio |
United States | University of North Carolina | Chapel Hill | North Carolina |
United States | Gastroenterology Associates of Tidewater | Chesapeake | Virginia |
United States | Indiana University Medical Center | Indianapolis | Indiana |
Lead Sponsor | Collaborator |
---|---|
Medtronic - MITG |
United States,
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Accuracy of Detection in Patients With Colonic Polyps - Sensitivity | The accuracy parameters (i.e. sensitivity) were evaluated for detection of patients with polyps equal or larger than 6 mm and for detection of patients with polyps equal or larger than 10 mm by constructing 2X2 matrix (i.e. PCCE-2 performance versus the standard colonoscopy), where sensitivity and specificity, are presented with 95% Cl based on the binomial distribution. Standard colonoscopy is considered the gold standard. | within 7 days | |
Primary | Accuracy of Detection in Patients With Colonic Polyps - Specificity | The accuracy parameters (i.e. specificity) were evaluated for detection of patients with polyps equal or larger than 6 mm and for detection of patients with polyps equal or larger than 10 mm by constructing 2X2 matrix (i.e. PCCE-2 performance versus the standard colonoscopy), where sensitivity and specificity, are presented with 95% Cl based on the binomial distribution. Standard colonoscopy is considered the gold standard. | within 7 days | |
Secondary | Diagnostic Yield of PillCam™ COLON 2 in Detecting Colonic Lesions | The diagnostic yield (%) of PCCE-2 and colonoscopy in visualizing a variety of colonic lesion excluding polyps (e.g. inflammation, diverticulosis and bleeding lesions) is provided. | within 7 days | |
Secondary | Percent of Participants With Scoring Index 3 or 4 (Good or Excellent) | Overall colon cleanliness was judged for capsule endoscopy and colonoscopy on a four-point grading index scale as follows:
poor cleansing level (Large amount of fecal residue.) fair cleansing level (Enough feces or dark fluid present to preclude a completely reliable examination.) good cleansing level (Small amount of feces or dark fluid, but not enough to interfere with examination.) excellent cleansing level (No more than small bits of adherent feces.) |
within 7 days | |
Secondary | Capsule Excretion Time | Capsule excretion time is defined as the duration of ingestion to capsule excretion time. The distribution of excretion times were categorized as follows:
capsule excreted within 4 hours capsule excreted within 6 hours capsule excreted within 8 hours capsule excreted 8 hours and above |
within 7 days |
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT02503696 -
Sample Collection Study to Evaluate DNA Markers in Subjects With Inflammatory Bowel Disease (IBD)
|
N/A | |
Completed |
NCT01063231 -
Evaluation of PillCam™ Colon 2 in Visualization of the Colon
|
Phase 3 | |
Terminated |
NCT01119027 -
Assessing Effectiveness of Laparoscopic Colorectal Surgical Skills
|
N/A | |
Completed |
NCT04074577 -
Computer Aided Detection, Tandem Colonoscopy Study
|
N/A | |
Not yet recruiting |
NCT04087824 -
Deep Learning Algorithm for Recognition of Colonic Segments.
|
N/A | |
Completed |
NCT03559543 -
Evaluation of Ocoxin®-Viusid® in Metastatic Colorectal Adenocarcinoma
|
Phase 2 | |
Terminated |
NCT02503631 -
Stool Sample Collection Protocol for Development of Screening Test for Colorectal Cancer and Other Digestive Tract Cancers
|
||
Completed |
NCT01600209 -
Exact CRC Screening Test: Stool Sample Collection Study to Support Assay Validation Testing
|
N/A | |
Completed |
NCT01260168 -
Multi-marker Stool Test for Detection of Colorectal Neoplasia: Marker Panel Selection and Technical Development Studies
|
N/A | |
Completed |
NCT00604162 -
PillCam™ Colon Capsule Endoscopy (PCCE) in the Visualization of the Colon
|
Phase 3 | |
Recruiting |
NCT04598880 -
Comparison of 1 Liter PEG With Ascorbate and Sodium Picosulfate / Magnesium Citrate for High Quality Colon Cleansing
|
Phase 4 | |
Completed |
NCT01738425 -
A Clinical Phase I Study on GIC-1001 in Healthy Volunteers
|
Phase 1 | |
Completed |
NCT04080843 -
Anlotinib Hydrochloride Capsules Combined With CAPEOX in RAS and BRAF Wild-type mCRC Patients
|
Phase 2 | |
Terminated |
NCT04644315 -
A Home-Based Approach Study to Evaluate the Efficacy and Safety of Alectinib in Locally-Advanced or Metastatic ALK-Positive Solid Tumors
|
Phase 2 | |
Completed |
NCT02291445 -
Comparing a 182mg Colon-targeted-delivery Peppermint Oil Capsule (Tempocol-ColoPulse®) and a 182mg Enteric-coated Peppermint Oil Capsule (Tempocol®), a Pharmacokinetic Study
|
Phase 2 | |
Completed |
NCT03037385 -
Phase 1/2 Study of the Highly-selective RET Inhibitor, Pralsetinib (BLU-667), in Participants With Thyroid Cancer, Non-Small Cell Lung Cancer, and Other Advanced Solid Tumors
|
Phase 1/Phase 2 | |
Completed |
NCT03139942 -
Optical Polyp Testing for In Vivo Classification
|
N/A | |
Completed |
NCT04263818 -
Endoscopist and Endoscope Motions During Colonoscopy
|
N/A | |
Recruiting |
NCT05923918 -
A Study to Evaluate Safety and Efficacy of PBK_M2101
|
Phase 3 | |
Completed |
NCT02647866 -
Study of a Monoclonal Antibody KHK4083 in Moderate Ulcerative Colitis
|
Phase 2 |