Clinical Trials Logo

Clinical Trial Details — Status: Not yet recruiting

Administrative data

NCT number NCT05064124
Other study ID # 143608
Secondary ID
Status Not yet recruiting
Phase
First received
Last updated
Start date March 2024
Est. completion date November 2024

Study information

Verified date February 2024
Source University College, London
Contact Sharon Cheung, MSc
Phone 02076795217
Email sharon.cheung@ucl.ac.uk
Is FDA regulated No
Health authority
Study type Observational

Clinical Trial Summary

The purpose of the study is to assess whether the AI characterisation system of the CADDIE device improves the endoscopists accuracy in the optical diagnosis of diminutive colorectal polyps in the bowel during colonoscopy. Participants will either have a colonoscopy with the assistance of the CADDIE device characterisation AI system ("intervention group") or have a colonoscopy in line with routine clinical practice i.e., without the CADDIE device characterisation AI system ("control group"). The randomisation method of this trial will allocate enrolled participants to the "intervention" group and to the "control" group by a technique similar to flipping a coin.


Description:

The CADDIE system comprises a computer attached to the output of the endoscopy stack and a screen which shows the normal video output of the colon in real-time. Using artificial intelligence (AI) software, it highlights the characteristics of a polyp to help the endoscopist in their optical diagnosis of the polyp histology. Pressing on a foot pedal, which is connected to the computer, presents the information from the AI software to the user as an overlay on the endoscopy screen in text format. The CADDIE device is capable of recording the video output of the colon in real-time irrespective of whether the CADDIE's AI system is active. In the endoscopist recruitment phase, we will identify endoscopists expertise and experience in colonoscopy. In the study phase of the trial, the endoscopist will be kept the same for the CADDIE and control arm. At the beginning of each procedure, participant information will be entered into an electronic system (Redcap) which will generate a random allocation into one of two arms. The CADDIE arm involves a colonoscopy assisted by the CADDIE AI system (i.e., AI software). The control arm is a colonoscopy without the CADDIE's polyp characterisation AI system (i.e., standard practice). Each endoscopist will have the CADDIE device present during all endoscopy lists and will record all procedures in both CADDIE and control arms. The CADDIE's polyp characterisation system (i.e., AI software) will only be active in the CADDIE arm. The recordings in the control arms will allow an extra post-hoc assessment of how CADDIE might have performed compared to the actual assessment by the endoscopist. In both arms of the trial, for each polyp the endoscopist detects, they will: 1. Measure the polyp size and capture images of the polyp: Polyps are to be measured using an instrument of known size. For polyps measured to be <10mm, the endoscopist will capture a still image of the polyp in both white light and Narrow Band Imaging (NBI) or equivalent imaging modality. 2. Optically diagnose the polyp: The endoscopist will optically diagnosis polyps <10mm, stating whether the diagnosis is made with high or low confidence. 3. Resect diminutive polyps: Management of rectosigmoid hyperplastic polyps will be standardised. Rectosigmoid polyps that are optically diagnosed as hyperplastic by the endoscopist will be resected/biopsied. If multiple rectal hyperplastic polyps are optically diagnosed by the endoscopist, a maximum of 5 will be resected/biopsied for histopathology. 4. Label the polyp with unique ID: Each polyp resected (regardless of size) must be labelled according to instructions of the Specimen Handling SOP. Each unique polyp ID will be logged in chronological order on a per colonoscopy basis and sent for histopathology. Histopathology will be referenced as the ground truth for polyp diagnosis and characterisation. 5. Complete documentation as per standard of care: Documentation will be made in the endoscopy report of polyp site, size, morphology, segmental Boston Bowel Preparation Score (BBPS). A photograph will also be taken of the caecum and stored in the endoscopy report. 6. Complete the optical diagnosis case report form (CRF): Populate the optical diagnosis CRF at the end of the procedure with the polyp ID of each polyp sample (regardless of size), their optical diagnosis of each polyp <10mm in size and whether their optical diagnosis was made with high or low confidence. In the CADDIE arm, the endoscopist presses the foot pedal once they have frozen an image of the polyp in the endoscopy screen in narrow band imaging (NBI) mode. This will output the CADDIE's characterisation of the polyp. Using this information and the endoscopist's own assessment, the endoscopist will log an optical diagnosis of the polyp and the confidence of their diagnosis (high or low). In the control arm, the endoscopist optically diagnoses the polyps without CADDIE's polyp characterisation function. The optical diagnosis will be assessed against the polyp histopathology which will be referred as the ground truth. Post-hoc analysis of the recorded footage will allow for comparison with the CADDIE generated polyp characterisation. Safety of the device will be assessed through monitoring of adverse events. Acceptability will be assessed through a qualitative questionnaire for the endoscopist, endoscopy nurse and participant in addition to measuring endoscopy markers such as caecal intubation time, procedural time, withdrawal time.


Recruitment information / eligibility

Status Not yet recruiting
Enrollment 420
Est. completion date November 2024
Est. primary completion date November 2024
Accepts healthy volunteers No
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria: - Participants scheduled to undergo a screening, surveillance or symptomatic colonoscopy with an endoscopist participating in the study phase of the trial. - Male and female participants aged 18 years or older at the time of informed consent. - Participants able to comprehend, sign and date the written informed consent document to participate in the study. Exclusion Criteria: - Emergency and/or inpatient colonoscopies - Participants with inflammatory bowel disease (IBD) - Participants with current Colorectal Cancer (CRC) - Participants with a contraindication for biopsy or polypectomy. These include: - Participants who have not withheld medications pre-disposing to bleeding at time of colonoscopy as per local site /national guidelines. - Participants with a history of haemostasis disorders (haemostasis disorders will include but will not be limited to: participants with haemophilia or other congenitally acquired clotting factor deficiencies, participants with cirrhosis with coagulopathy, participants known to have thrombocytopenia (<80,000 platelet/ul) and individuals with Von Willebrand's disease or other known platelet malfunction disorders) - Participant is enrolled in another research study with an investigational medicinal product (IMP) or non-IMP that pre-disposes them to bleeding

Study Design


Intervention

Device:
CADDIE - Computer Aided Detection and Diagnosis for Intelligent Endoscopy
CADDIE assisted polyp detection CADDIE assisted polyp characterisation

Locations

Country Name City State
United Kingdom University College London Hospitals NHS Foundation Trust London

Sponsors (1)

Lead Sponsor Collaborator
University College, London

Country where clinical trial is conducted

United Kingdom, 

Outcome

Type Measure Description Time frame Safety issue
Primary The primary objective of this study is to evaluate whether the CADDIE system improves endoscopists accuracy in the optical diagnosis of diminutive colorectal polyps (=5mm). The primary endpoint will be the proportion of diminutive colorectal polyps optically diagnosed correctly by endoscopists (correct optical diagnoses divided by total number of diminutive polyps), expressed as a percentage, in the CADDIE arm compared to the control arm, with the polyp histopathology being referenced as the ground truth. 1 year
Secondary To determine whether using the CADDIE system improves endoscopists accuracy in the optical diagnosis of diminutive polyps in the rectosigmoid area. The endpoint will be the proportion of diminutive rectosigmoid colorectal polyps optically diagnosed correctly by endoscopists (correct optical diagnoses divided by total number of diminutive rectosigmoid polyps), expressed as a percentage, in the CADDIE arm compared to the control arm, with the polyp histopathology being referenced as the ground truth. 1 year
Secondary To determine whether using the CADDIE system improves the negative predicator value (NPV) of endoscopists for optically diagnosing diminutive adenomatous polyps in the rectosigmoid area. The endpoint will be the NPV in optically diagnosing rectosigmoid diminutive adenomas in the CADDIE arm compared to the control arm, with the polyp histopathology being referenced as the ground truth. 1 year
Secondary To assess the concordance of colonoscopy surveillance intervals in the CADDIE arm determined using endoscopists optical diagnosis against histopathology derived surveillance intervals (ground truth). The concordance of colonoscopy surveillance intervals in the CADDIE arm when using endoscopists CADDIE assisted OD in comparison to histopathology derived intervals (ground truth) - per patient analysis. 1 year
Secondary To assess the concordance of colonoscopy surveillance intervals in the control arm determined using endoscopists optical diagnosis against histopathology derived surveillance intervals (ground truth). The concordance of colonoscopy surveillance intervals in the control arm when using endoscopists OD without the CADDIE system in comparison to histopathology derived intervals (ground truth) - per patient analysis. 1 year
Secondary To compare the accuracy of the colonoscopy surveillance intervals when the endoscopists uses the CADDIE system (CADDIE arm) compared to without the CADDIE system (control arm). To compare the concordance of colonoscopy surveillance intervals against histopathology derived surveillance intervals (ground truth) in the CADDIE arm with the control arm (expressed as a percentage) - per patient analysis. 1 year
Secondary To evaluate how the CADDIE system influences the endoscopists confidence in their OD. Compare the rate of endoscopists high-confidence optical diagnosis when using the CADDIE system compared to without. 1 year
Secondary Evaluate the safety of the CADDIE system in clinical application. Frequency of adverse events based on maximum severity of event for each participant in each arm. Adverse events will be recorded at 30 days post-procedure. 1 year
Secondary Assess the integration of the CADDIE system into the normal colonoscopy clinical workflow. i) Compare caecal intubation time in both arms of the study. ii) Compare caecal intubation rate in both arms of the study. iii) Endoscopist/endoscopy nurse/patient experience and acceptability of the CADDIE system assessed by qualitative questionnaire. 1 year
See also
  Status Clinical Trial Phase
Completed NCT04192565 - A Prospective Investigation of the ColubrisMX ELS System N/A
Recruiting NCT04516785 - Reducing Colonoscopies in Patients Without Significant Bowel Disease
Not yet recruiting NCT05776381 - The Impact of a Patient Decision Aid on Treatment Choices for Patients With an Unexpected Malignant Colorectal Polyp Phase 2
Recruiting NCT05660317 - Assessment of Endoscopic Tip Control Using a Novel Score Based on the Snare Tip Soft Coagulation of Polypectomy Margin Defects
Recruiting NCT06040632 - IMPROVE-pT1: Accurate Allocation of Completion Resection in Early Colorectal Cancer
Withdrawn NCT05606081 - Predicting Risk for Post-polypectomy Colorectal Cancer N/A
Recruiting NCT05576506 - Application of Hyperspectral Imaging Analysis Technology in the Diagnosis of Colorectal Cancer Based on Colonoscopic Biopsy
Not yet recruiting NCT05545189 - Polyp Histology Prediction by Artificial Intelligence
Recruiting NCT06032104 - Feasibility and Colorectal Benefits of Pulses Supplementation N/A
Completed NCT05477836 - Feasibility and Safety of MiWEndo-assisted Colonoscopy N/A
Completed NCT04111601 - BLI Based Adenoma Surveillance Strategy
Completed NCT03822390 - Diagnostic Performance of a Convolutional Neural Network for Diminutive Colorectal Polyp Recognition
Recruiting NCT05545787 - Cold or Hot Snare Endoscopic Mucosal Resection for 10-19mm Non-pedunculated Colorectal Polyps N/A
Recruiting NCT04149184 - Computer-aided Detection Device in Standard Colonoscopy N/A
Recruiting NCT03359343 - Computer-assisted Diagnosis System Based on Linked Colour Imaging N/A
Completed NCT04349787 - Improving Optical Diagnosis of Colorectal Polyps Using CADx and BASIC.
Not yet recruiting NCT05041478 - Cold Snare Endoscopic Mucosal Resection (EMR) vs Cold EMR With Margin Snare Tip Soft Coagulation (STSC) N/A
Active, not recruiting NCT05846295 - Online Education Module to Accurately Classify Polyp Size N/A
Completed NCT03712059 - National Colorectal Polyp Care
Not yet recruiting NCT06193356 - Detection of Endoscopic Resection Scars and Delineation of Recurrence is Trainable N/A