Clinical Trials Logo

Cochlear Implantation clinical trials

View clinical trials related to Cochlear Implantation.

Filter by:

NCT ID: NCT03256097 Completed - Clinical trials for Cochlear Implantation

Voice Guard Processing Evaluation in a Cohort of Subjects Implanted With the Neuro Cochlear Implant System

Start date: July 25, 2018
Phase: N/A
Study type: Interventional

The study aims to compare two different cochlear implant sound processing strategies. All the participants will start off with a sound processing strategy called the XDP (extended performance). At the 3 month stage, half of the participants would randomly be selected and offered a sound processing strategy called the Voice Guard. Following that, the sound processing strategies will be altered and evaluated every 3 months at the 6th, 9th and 12th month of cochlear implant use.

NCT ID: NCT02902497 Completed - Clinical trials for Cochlear Implantation

Impact of the Surgical Experience on Cochleostomy Location: A Comparative Temporal Bone Study Between Endaural and Posterior Tympanotomy Approaches for Cochlear Implantation

Start date: March 2014
Phase: N/A
Study type: Observational

The goal of this study was to evaluate, in the hands of an inexperienced surgeon, the cochleostomy location of an endaural approach (MINV) compared to the conventional posterior tympanotomy (MPT) approach. Since 2010, the investigators use in the ENT department of Nice a new surgical endaural approach to perform cochlear implantation. In the hands of an inexperienced surgeon, the position of the cochleostomy has not yet been studied in detail for this technique. This is a prospective study of 24 human heads. Straight electrode arrays were implanted by an inexperienced surgeon: on one side using MPT and on the other side using MINV.

NCT ID: NCT02830659 Active, not recruiting - Clinical trials for Cochlear Implantation

Cochlear Implants Registry in Thailand Project

CIRT
Start date: July 2016
Phase: N/A
Study type: Observational

The purpose of this study is to determine the outcome of cochlear implant including post operative hearing ability, developing of language, complication from cochlear implant, quality of life, and success factor of cochlear implant.

NCT ID: NCT01940783 Recruiting - Clinical trials for Cochlear Implantation

Assessment of the AB HiFocusTM Mid Scala Electrode Movement Using Cone Beam Imaging Following Cochlea Implantation

ABMS1
Start date: September 2013
Phase: N/A
Study type: Interventional

One of the contributing factors to the variability in outcomes amongst Cochlear Implant (CI) recipients was reported to be the placement of the electrode array in the scala tympani. It seems that the correct placement of the electrode initially into the scala tympani and subsequent avoidance of dislocation into the scala vestibuli as the insertion progresses, is a key factor in achieving good speech perception outcomes. Another important aspect related to the performance is the achievement of consistent electrical coverage with the electrode. Data reported for electrodes of different manufacturers give depths ranging from 240 - 600 degrees showing the considerable variation across subjects. The HiFocus mid scala electrode was developed to cover one and a quarter turn and with the pre-curved design to be less susceptible to variations in individual cochlea dimensions and insertion techniques. A further mechanical feature of the pre-curved design is the avoidance of forces against the cochlear lateral wall and associated lower susceptibility of the electrode for moving out of the cochlea following insertion. Recently, a cone beam CT (CBCT) technique is being explored in the field of ENT with the potential to overcome some of the issues associated with the conventional CT techniques such as scattering, radiation and low isometric resolution. Images with comparable details to those of e.g. micro CTs are possible with much lower radiation dose. Modern imaging software i.e. 3D Slicer (www.slicer.org) may be used for 3D reconstruction, post processing and Brainsfit for registration. Registration is the alignment of two scans in the same coordinate system. This enables the identification of differences between two images recorded at time x and y. Once accurately superimposed any difference between the two images may be identified with an accuracy of 0.2 mm. Using these methods, one can assess the stability and the position of the electrode in the cochlea. Objective: The primary objectives of this study are to evaluate the feasibility of using cone beam CT technique in combination with (high resolution) MRI to identify electrode movements following cochlear implant surgery and identify the inter-scalar position of the HFms electrode. The secondary objective is to quantify the average insertion depth and variations of the HFms electrode