Cochlear Implant Clinical Trial
Official title:
The Effect of Cochlear Implant on Postural Control
Some patients are having balance problems after cochlear implant surgery. There are contradictory reports about the effect of the implant on postural control. While the cochlear implant is working, an electrical current is continuously stimulating the cochlear nerve which is in close proximity with vestibular ganglion and nerve. This stimulation may contribute to vestibular signals to the central system. The aim of the study is to investigate if this stimulation has any effect on postural control.
Adult patients who had unilateral cochlear implantation will be included. Postural stability measurements will be done by the Biodex Balance System. Three preprogrammed main tests and their 9 subtests will be applied. Postural stability, fall index, sensory integration will be calculated. All tests will be done in four conditions; implant off(1), implant on(2), implant on music on(3), and implant off again(4). ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT04222296 -
Bimodal, CROS and Severe Profound Hearing Loss Study
|
N/A | |
Completed |
NCT04577118 -
The iotaSOFT Insertion System Safety Study
|
N/A | |
Withdrawn |
NCT04041596 -
Degree of Benefit From Low-Frequency Acoustic Amplification Using the Advanced Bionics Acoustic Earhook
|
Phase 4 | |
Completed |
NCT01737489 -
Title: "Development and Implementation of Innovative Auditory Training Methods and Verification of These Training Methods"
|
N/A | |
Completed |
NCT03304106 -
Clinical Investigation of New CI Delivery Models in an Adult Nucleus CI Population
|
N/A | |
Active, not recruiting |
NCT03685461 -
AB-Intra- and Post-Operative Measures of Auditory Function
|
N/A | |
Completed |
NCT03515473 -
Subjective and Objective Results With CI Electrode Types
|
||
Terminated |
NCT03025386 -
Establish a Concordance Between the Mismatch Negativity Amplitude and a Score of Logatoms Discrimination
|
N/A | |
Completed |
NCT02966379 -
Hearing Preservation and Electro-acoustic Stimulation With EVO® Electrode Lead and Zebra® Sound Processor
|
N/A | |
Not yet recruiting |
NCT05275712 -
Outcome of Cochlear Implant in Assiut University
|
||
Completed |
NCT03202797 -
Optimizing Regulation of a Cochlear Implant in Patients With Functional Contralateral Audition.
|
||
Recruiting |
NCT05360212 -
Anatomy-based Fitting in Cochear Implant Users
|
N/A | |
Not yet recruiting |
NCT06142682 -
Dexamethasone Eluting Cochlear Implant: a Pivotal Study
|
N/A | |
Recruiting |
NCT03886168 -
Pediatric Image-Guided Cochlear Implant Programming
|
N/A | |
Enrolling by invitation |
NCT03306082 -
Image-guided Cochlear Implant Programming (IGCIP)
|
N/A | |
Enrolling by invitation |
NCT04320251 -
Tissue Growth Characterization for Cochlear Implant Users
|
N/A | |
Recruiting |
NCT05079867 -
Cochlear Trauma, Functional and Structural Preservation in Cochlear Implant Surgery
|
||
Recruiting |
NCT06086041 -
Predictive Study on Hearing Rehabilitation After Cochlear Implant
|
||
Active, not recruiting |
NCT04722042 -
Place-based Mapping in EAS Listeners
|
N/A | |
Recruiting |
NCT04711538 -
Role of Diagnostic Imaging in Cochlear Implant
|