Cochlear Hearing Loss Clinical Trial
Official title:
Robotic and Manual Cochlear Implantation: An Intra-individual Study of Speech Recognition and Electrode Holder Position
Cochlear implantation (CI) allows rehabilitation for patients with severe to profound hearing impairment. Although the use of a robotic assistant provides technical assistance to the surgeon, the assessment of the impact of its use on auditory outcomes remains uncertain, due to inter-individual variability of preoperative audiometric thresholds and the various possible intrascalar positions of the electrode array. WThe investigators aim to compare the hearing results of patients who underwent bilateral cochlear implantation, one side was performed with manual insertion and the other side with robot-assisted insertion. The electrode array intrascalar positioning and the surgery duration were also studied. This retrospective intra-individual study involved 10 patients who underwent bilateral cochlear implantation. The unique composition of this cohort enabled the investigators to utilize each patient as their own control.
Cochlear implantation (CI) allows rehabilitation for patients with severe to profound hearing impairment. Although the use of a robotic assistant provides technical assistance to the surgeon, the assessment of the impact of its use on auditory outcomes remains uncertain, due to inter-individual variability of preoperative audiometric thresholds and the various possible intrascalar positions of the electrode array. The investigators aim to compare the hearing results of patients who underwent bilateral cochlear implantation, one side was performed with manual insertion and the other side with robot-assisted insertion. The electrode array intrascalar positioning and the surgery duration were also studied. This retrospective intra-individual study involved 10 patients who underwent bilateral cochlear implantation. The unique composition of this cohort enabled the investigators to utilize each patient as their own control. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT03212924 -
Listening Effort in Cochlear Implant Users
|
N/A | |
Withdrawn |
NCT04041596 -
Degree of Benefit From Low-Frequency Acoustic Amplification Using the Advanced Bionics Acoustic Earhook
|
Phase 4 | |
Recruiting |
NCT04610112 -
PMCF on Safety and Performance of HiResTM Ultra/Ultra 3D Cl Mid-Scala Electrodes in Adults With Severe-to-profound Hearing Loss
|
||
Completed |
NCT04610216 -
Investigation of the Automatic Technology on the Naída M Hearing Devices
|
||
Completed |
NCT03248856 -
Triamcinolone Levels in Cochlear Perilymph
|
Phase 1 | |
Completed |
NCT03288753 -
Comparison Between Neuro 1 and Neuro 2 Cochlear Implant Speech Processors
|
N/A | |
Completed |
NCT04048239 -
Development of a Robotic Minimally Invasive Pathway for Cochlear Implantation
|
N/A | |
Completed |
NCT04815343 -
Investigation of the Naída CI M90 Sound Processor in Various Acoustic Scenarios
|
N/A | |
Completed |
NCT04145661 -
Non-linear Frequency Compared to Conventional Processing in Patients With and Without Cochlear Dead Regions.
|
N/A | |
Recruiting |
NCT06114680 -
Evaluation of the CochSyn Test Prototype to Measure Cochlear Synaptopathy
|
N/A | |
Completed |
NCT03756337 -
Neuro 1 vs. Neuro 2 Sound Processors
|
N/A | |
Completed |
NCT04120181 -
A New Predictor Marker for Cochlear Implants Infection
|
||
Terminated |
NCT05586555 -
A Monocentric Study Evaluating Pupillometry as an Objective Measurement for CI Fittings
|
N/A | |
Recruiting |
NCT04929470 -
Safety and Performance of Ultra/Ultra 3D Cl With HiFocus SlimJ Electrode in Adults With Severe-to-profound Hearing Loss
|
||
Completed |
NCT04183348 -
Evaluation of the Effect of a Visio-Hearing Training Protocol on Spatial Hearing in Subjects With Hearing Loss
|
N/A | |
Not yet recruiting |
NCT06420921 -
MeasurIng and Restoring Auditory Awareness for Cochlear Implant Listeners in noisE
|
N/A | |
Recruiting |
NCT05486637 -
Vocal Emotion Communication With Cochlear Implants
|
Early Phase 1 | |
Recruiting |
NCT06301581 -
Retrospective Analysis of Speech Performance Using the HiRes Ultra and HiRes Ultra 3D Cochlear Implant
|
||
Recruiting |
NCT06301568 -
Retrospective Analysis of Long-term Speech Performance in Cochlear Implant Recipients Using Electro-acoustic Stimulation
|
||
Withdrawn |
NCT04651660 -
Using Electrocochleography During Cochlear Implantation of the Neuro Zti.
|
N/A |