Clinical Trials Logo

Clinical Trial Summary

This study investigates a newly developed test, The CochSyn test that can quantify cochlear synaptopathy (CS) (a new type of sensorineural hearing loss (SNHL)) earlier than the current golden standard pure-tone audiogram.This newly developed test is based on auditory evoked brain potentials. A hardware prototype (the Cochsyn test prototype) was developed to use the Cochsyn test in clinical practice. Additionally a CS-based sound-processing algorithm (CoNNear) that is designed to improve speech intelligibility in subjects that are identified to have CS, will be investigated in this study.


Clinical Trial Description

Cochlear synaptopathy is a new type of sensorineural hearing loss (SNHL) and is related to ageing, noise exposure and ototoxicity. There is currently no diagnostic test of CS on the market, whereas CS is an important form of SNHL. CS occurs before the golden standard clinical hearing test (pure- tone audiogram in which participants raise their hand when hearing tones of different frequencies and the threshold of hearing is determined), shows any signs of hearing damage. The investigators have developed a test, the CochSyn test that may quantify SNHL earlier than the audiogram. The newly developed test is based on auditory evoked potentials. This is a method in which an auditory stimulus is presented, and encephalogram (EEG) electrodes capture the sound-evoked brain potentials. The most popular auditory evoked potential metric to diagnose sensorineural hearing loss (SNHL) is the auditory brainstem response (ABR). The first animal research studies on CS confirmed that the ABR wave-I amplitude is a sensitive marker of CS when the inflicted hearing damage is well-controlled and specific. Even though it can be assumed that the ABR wave-I amplitude will also be sensitive to CS in humans, it may not be a differential marker for it, and hence other candidate auditory evoked potential markers for CS have been investigated in recent studies. In particular, the envelope-following-response (EFR), has also been shown to be specific to CS in animal research studies. EFRs are recorded using the standard ABR electrode montage but use another type of stimulus. Based on model simulations and a recent study in which the investigators compared candidate EFR markers for use in human studies , the investigators have developed a new stimulus for EFRs that uses both a different type of modulator waveform and a different analysis method than was adopted earlier. In this trial, the investigators wish to test the performance of the new method (the CochSyn test) in listeners with or without self-reported hearing difficulties using a newly developed hardware prototype (the CochSyn test prototype), dedicated for the CochSyn-test in clinical practice. The assessment also includes the testing of a CS-based sound-processing algorithm (CoNNear) that is designed to improve speech intelligibility in subjects that are identified to have CS, based on our CochSyn test. To this end, the investigators will first assess whether our CochSyn test prototype is equally good at capturing the standard ABR waveform as a comparator device available on the market (the Intelligent Hearing Systems Universal Smart Box). The investigators will also test which stimulation characteristics and electrode configurations for the CochSyn test are best able to quantify individual differences in standard objective hearing tests (audiogram, otoacoustic emission, speech reception thresholds) and subjective hearing complaints (validated HHIE-s questionnaire). ;


Study Design


Related Conditions & MeSH terms


NCT number NCT06114680
Study type Interventional
Source University Ghent
Contact Iris Arweiler
Phone +3293314872
Email Iris.Arweiler@UGent.be
Status Recruiting
Phase N/A
Start date November 13, 2023
Completion date June 30, 2025

See also
  Status Clinical Trial Phase
Completed NCT04281953 - Impact on Quality of Life of Long-term Ototoxicity in Cancer Survivors
Not yet recruiting NCT05973669 - MED-EL Remote Care Multi-Center Feasibility Study N/A
Completed NCT04601909 - FX-322 in Adults With Age-Related Sensorineural Hearing Loss Phase 1
Active, not recruiting NCT04479761 - Sensory Integration of Auditory and Visual Cues in Diverse Contexts N/A
Recruiting NCT05043207 - A Study Protocol for the Validation of UAud in a Clinical Setting. N/A
Recruiting NCT04070937 - Correlation of Radiological Lesions With Vestibular Function in Patients With Bilateral Vestibulopathy
Recruiting NCT04066270 - Inventory of Radiological and Vestibular Function in Cochlear Implant Candidates
Completed NCT03512951 - Subjective Evaluation of a Sound Processing Method for Hearing Aids on Auditory Distance Perception N/A
Completed NCT05855005 - Direct-to-Consumer Hearing Aids and Listening Effort N/A
Recruiting NCT05599165 - Speech Perception in Bimodal Hearing N/A
Completed NCT05101083 - Speech Intelligibility in Quiet and Noise for New vs. Legacy Hearing Aids N/A
Completed NCT05521308 - Investigating Hearing Aid Frequency Response Curves N/A
Completed NCT05072457 - Benefit of Assistive Listening Device for Lateralization N/A
Recruiting NCT05776459 - Efficacy and Safety of AC102 Compared to Steroids in Adults With Idiopathic Sudden Sensorineural Hearing Loss (ISSNHL) Phase 2
Completed NCT05086276 - FX-322 in Adults With Acquired Sensorineural Hearing Loss Phase 2
Recruiting NCT06058767 - Preschool Hearing Screening N/A
Completed NCT05180630 - Sound Quality Comparisons With Different Hearing Aid Couplings and Venting Systems N/A
Completed NCT03613909 - Acceptance of the CP950 Sound Processor N/A
Active, not recruiting NCT03352154 - Long Latency Auditory Evoked Potentials (P300) Outcomes in Patients With Unilateral Cochlear Implants N/A
Completed NCT04629664 - FX-322 in Adults With Severe Sensorineural Hearing Loss Phase 1