Chronic Kidney Failure Clinical Trial
Official title:
The Gambro Polyflux HD-C4 Big Ease Of Use And Thrombogenicity Study
Verified date | May 2011 |
Source | Gambro Renal Products, Inc. |
Contact | n/a |
Is FDA regulated | No |
Health authority | United States: Institutional Review Board |
Study type | Observational |
The purpose of this study is to collect information on the ease of use and thrombogenicity of the Polyflux HD-C4 Big and Fresenius Optiflux 180NR or 200NR dialyzers under conditions of routine clinical use for hemodialysis.
Status | Completed |
Enrollment | 33 |
Est. completion date | May 2008 |
Est. primary completion date | May 2008 |
Accepts healthy volunteers | No |
Gender | Both |
Age group | 18 Years and older |
Eligibility |
Inclusion Criteria: - Hemodialysis patients 18 years of age or older Exclusion Criteria: |
Time Perspective: Prospective
Country | Name | City | State |
---|---|---|---|
United States | Advanced Dialysis Center of Potomac | Arlington | Virginia |
United States | Advanced Dialysis Center of Easton | Easton | Maryland |
Lead Sponsor | Collaborator |
---|---|
Gambro Renal Products, Inc. | Advanced Dialysis Center of Easton, Advanced Dialysis Center of Potomac |
United States,
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Ease of Use: Priming Blood Side | For every study treatment/dialyzer, the nursing staff rated the ease of priming blood side as follows: Very Easy:Air is easily removed without knocking or clamping procedures. Acceptable:Knocking and/or clamping required for efficient air removal. Difficult:Knocking and/or clamping and additional volume of saline or extended recirculation needed to remove air. Very Difficult:Air could not be removed. |
Priming at each treatment | No |
Primary | Ease of Use: Priming Dialysate Side | For every study treatment/dialyzer, the nursing staff rated the ease of priming dialysate side as follows: Dialysate Side at 500 ml Priming Volume (check one): Perfect: No air visible. Acceptable: Some air visible, but considered insignificant. Not Acceptable: Additional actions needed to sufficiently remove air. |
Priming at each treatment | No |
Primary | Dialyzer Assessment: Fiber Condition | For every study treatment/dialyzer, the nursing staff rated the condition of the dialyzer fibers after rinse-back as follows: Very Good:All fibers appear white. Good:Few fibers (less than 10) appear PINK / RED. (check one) Poor:Several fibers (more than 10) appear PINK / RED. (check one) Very Poor:Most fibers (more than 75%) appear PINK / RED. (check one) |
Each treatment: assessment of the condition of the dialyzer fibers after rinse-back | No |
Primary | Dialyzer Assessment: Arterial Header Condition | For every study treatment/dialyzer, the nursing staff rated the condition of the arterial header after rinse-back as follows: Very Good:Surface as clean as expected. Good:Distinct red ring appears at the dialyzer wall. Poor:Significant appearance of clots, randomly distributed on the surface. Very Poor:Completely red and/or covered with clots. |
Each treatment: assessment of the condition of the arterial header after rinse-back | No |
Primary | Dialyzer Assessment: Venous Header Condition | For every study treatment/dialyzer, the nursing staff rated the condition of the venous header after rinse-back as follows: Very Good:Surface as clean as expected. Good:Distinct red ring appears at the dialyzer wall. Poor:Significant appearance of clots, randomly distributed on the surface. Very Poor:Completely red and/or covered with clots. |
Each treatment: the assessment of the condition of the venous header after rinse-back | No |
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT06216015 -
Exercise Training and Kidney Transplantation
|
N/A | |
Completed |
NCT00806130 -
Health Related Quality of Life and Cognitive Function Among Norwegian Dialysis Patients
|
||
Completed |
NCT00781690 -
Reduction of Heparin Dose in Dialysis With Evodial System
|
N/A | |
Completed |
NCT00153621 -
Prevalence of Proteinuria and Chronic Kidney Disease in Pediatric HIV-Infected Patients
|
N/A | |
Completed |
NCT06165211 -
Nature-Based Sound Application For Hemodialysis Patients
|
N/A | |
Not yet recruiting |
NCT04013620 -
CNI Transient Replacement by Belatacept From 3 to 12 Months Post Transplantation in Patients With Early Graft Dysfunction
|
Phase 3 | |
Withdrawn |
NCT03998917 -
Pathophysiological Characterization of the Neuromuscular Function of a Population With Multiple Comorbidities Suffering From Chronic Renal Failure in Pre-dialysis.
|
||
Completed |
NCT02586376 -
Effects of the Low-level Laser Therapy (LLLT) on Muscle Strength (MS) of the Patients With Kidneys Failure (KF)
|
N/A | |
Completed |
NCT00794326 -
Clinical Evaluation of Low Sodium Peritoneal Dialysis (PD) Solution on Hypertensive Patients Treated With PD
|
Phase 3 | |
Completed |
NCT05185999 -
Icodextrin Study to Test Short-Term Safety, Tolerability and Preliminary Efficacy of Sodium-Free Solution in PD Patients
|
Phase 1 | |
Completed |
NCT03076528 -
An Innovative Virtually Supervised Exercise for Dialysis Patients
|
Phase 2 | |
Completed |
NCT02513303 -
Trial to Evaluate the Sirolimus-Eluting Collagen Implant on AV Fistula Outcomes
|
Phase 3 | |
Unknown status |
NCT00788905 -
Comparison of Conventional Dialysis and the Allient System
|
N/A | |
Completed |
NCT00804453 -
Evaluation of the Biocompatibility of Cartridge Blood Set Versus Standard Blood Line
|
N/A | |
Completed |
NCT01085552 -
Bioequivalence of a Single Subcutaneous Dose of Epoetin Beta in Healthy Japanese and Caucasian Male Subjects
|
Phase 1 | |
Completed |
NCT00694824 -
Vascular Calcification's Risk Factors in Haemodialysis Patients
|
||
Completed |
NCT00074620 -
A Clinical Study to Assess the Safety of PEG-Hirudin (SPP200) Compared to Heparin in Patients Who Are on Haemodialysis
|
Phase 2 | |
Withdrawn |
NCT06030050 -
Animal Assisted Intervention for Hemodialysis Outpatients
|
N/A | |
Recruiting |
NCT05562869 -
Belatacept as a Replacement for CNIs 3 to 12 Months Post-transplantation in Patients With Early Graft Dysfunction
|
Phase 3 | |
Completed |
NCT03437538 -
Reduction Ratio and Clearance During Hemodialysis With MCO-filter Compared to HDF With Standard High-flux Filter
|
N/A |