Clinical Trials Logo

Clinical Trial Summary

The investigators wish to study the magnetic field map using magnetocardiography (MCG) in subjects undergoing computed tomographic angiography (visualization of the heart arteries using CT scanning, CTA). The main purposes is to investigate if MCG is capable of detecting the presence of obstructive coronary artery disease (CAD) as detected by CT angiography (CTA) as well if the MCG can exclude the presence of CAD as defined by CTA.

Secondarily the investigators will look at the correlation of MCG with non-obstructive CAD and the correlation of MCG with other tests (treadmill testing, stress echo or nuclear scan, coronary angiography) done as part of the work up for CAD.


Clinical Trial Description

Cardiomagnetism refers to the detection, analysis and interpretation of the magnetic fields generated by the electrical activity of the heart. The peak value of the magnetic fields of the heart is more than a million times smaller than the Earth's magnetic field. A major breakthrough in the capability of measuring such small fields came with the invention of the SQUID (superconducting quantum interference device) in the late sixties. The first magnetocardiograms (MCGs) measured with the SQUID were recorded by Cohen et al. in 1970. These earlier measurements were performed in very expensive magnetically shielded rooms, initially utilizing only one or two SQUID probes. In the eighties this technology was tested in several laboratories creating a magnetic field map by moving one SQUID sequentially above the chest to create an image of the whole hearts magnetic field. These maps were then attempted correlated with various pathologies (1).

Since then the technology has been greatly improved and several multi-channel machines are in use across the world for research purpose for arrhythmia localization and ischemia detection. However, at present time, only one company (CardioMag Imaging, Schenectady, New York) has developed a machine that operates outside a shielded room.

The CardiomagImaging (CMI) Magnetocardiograph (MCG) is capable of noninvasive recording of magnetic fields arising from the electrical activity of the heart with very high spatial and temporal resolution. The temporal trace of the MCG is analogous to an ECG, and, similarly, can be recorded in multiple leads. This MCG device has been specifically developed for the general purpose (outside shielded room) of non-contact, non-invasive diagnostics of ischemia.

The CMI MCG device has been approved by the FDA as a safe tool to measure and record the magnetic field arising from the heart's electrical currents. It is awaiting FDA approval for the specific diagnosis of ischemia in chest pain patients (2,3).

We have been using the CMI 9-channel MCG for detection of ischemia in patients admitted to Cedars-Sinai Medical Center for acute chest pain syndrome. The results are very exciting and have been published in abstracts and one manuscript, with another manuscript in submission (4,5). In summary, we studied 75 patients with acute chest pain and 65 healthy volunteers and found a very strong association with an abnormal MCG scan and ischemia (p<0.0001). The sensitivity, specificity, PPV and NPV was 87.1%, 85.7%, 64.3%, and 95.7%, respectively. In comparison, the diagnostic value of the stress SPECT imaging was 91.3%, 75.0%, 75.0%, and 91.3%, for sensitivity, specificity, positive and negative predictive value, respectively. These results were achieved without the use of stress provocation, contrast administration, or any ionizing radiation, and the results were available immediately.

Since starting the chest pain protocol another diagnostic imaging technology has become more widespread used, 64-slice CT angiography. This technology utilizes a fast CT scanner and involves administration of a contrast agent, but avoids the invasiveness of a heart catheterization. The accuracy of detection of CAD and its exclusion is very high as compared with angiography (6). Although minimally invasive, the CT angiogram does involve a radiation dose similar to that used with stress nuclear testing, approximately 900 to 1100 mrem (6) and the iodine contrast used may cause contrast nephropathy, especially in diabetics and those with already impaired renal function. The use of this technology provides an opportunity to find subjects with normal coronary arteries with accuracy close to as high as for invasive coronary angiography. To date, this population has been hard to study, since subjects with a normal stress test rarely will undergo more invasive studies.

Therefore, we wish to conduct this correlative study with CT angiography and the entirely noninvasive and risk free MCG to see if we in the future may be able to avoid some of the risks associated with CTA. We think that we may find that subjects with a clearly abnormal MCG may not need CTA, but could proceed directly to angiography and possible angioplasty. ;


Study Design

Observational Model: Case Control, Time Perspective: Prospective


Related Conditions & MeSH terms


NCT number NCT00574561
Study type Observational
Source Cedars-Sinai Medical Center
Contact
Status Withdrawn
Phase N/A
Start date July 2007
Completion date December 2009

See also
  Status Clinical Trial Phase
Completed NCT04153006 - Comparison of Fingerstick Versus Venous Sample for Troponin I.
Recruiting NCT03664973 - Serratus Plane Block for Rib Fractures N/A
Completed NCT02905383 - The Effect of Exercise on Physical Function and Health in Older People After Discharge From Hospital N/A
Not yet recruiting NCT05649891 - Checklists Resuscitation Emergency Department N/A
Withdrawn NCT03906812 - A Randomized Trial of Telemetry Compared With Unmonitored Floor Admissions in ED Patients With Low-Risk Chest Pain N/A
Active, not recruiting NCT02892903 - In the Management of Coronary Artery Disease, Does Routine Pressure Wire Assessment at the Time of Coronary Angiography Affect Management Strategy, Hospital Costs and Outcomes? N/A
Completed NCT02538861 - Acute Chest Pain Imaging in the ED With the Combine CCTA and CT Perfusion
Completed NCT02538770 - Rapid Viral Diagnostics in Adults to Reduce Antimicrobial Consumption and Duration of Hospitalization N/A
Completed NCT01931852 - Cardiac Magnetic Resonance Imaging Strategy for the Management of Patients With Acute Chest Pain and Detectable to Elevated Troponin N/A
Completed NCT02440893 - Understanding the Effect of Metformin on Corus CAD (or ASGES)
Completed NCT01665521 - Efficacy Evaluation of the HEART Pathway in Emergency Department Patients With Acute Chest Pain N/A
Recruiting NCT01542086 - Comparison of the Cost-Effectiveness of Coronary CT Angiography Versus Myocardial SPECT in Patients With Intermediate Risk of Coronary Heart Disease N/A
Completed NCT01486030 - Effect of Exercise Stress Testing on Peripheral Gene Expression Using Corus CAD (or ASGES) Diagnostic Test
Completed NCT01604655 - ProspEctive First Evaluation in Chest Pain Trial N/A
Terminated NCT01836211 - High-Sensitivity Troponin T and Coronary Computed Tomography Angiography for Rapid Diagnosis of Emergency Chest Pain N/A
Completed NCT01163019 - 2D Strain Echocardiography for Diagnosing Chest Pain in the Emergency Room N/A
Completed NCT00709670 - ComParative Diagnostic Study Between Multislice Computed Tomography (MSCT) and Stress Echography in Coronarin Patients. N/A
Completed NCT00536224 - Chest Pain Observation Unit Risk Reduction Trial N/A
Terminated NCT00221182 - Stem Cell Study for Patients With Heart Disease Phase 1/Phase 2
Completed NCT00075088 - Tele-Electrocardiography in Emergency Cardiac Care Phase 3