Clinical Trials Logo

Clinical Trial Summary

Up to two-thirds of intensive care unit patients require central venous catheterization for which ultrasound-guided placement is now recommended. In this context, the team performed a prospective randomized simulation trial on a mannequin ("reduced torso model"), to compare the standard ultrasound guidance technique with an ultrasound-guided technique assisted by a new needle-steering device. The preliminary results show a statistically significant improvement in subclavian venipuncture (shorter success time, fewer multiple skin punctures, fewer punctures of the posterior wall of the subclavian vein and needle redirection, greater comfort) and argue for a clinical trial to test the performance of this new device in situation with intensive care unit patients. The hypothesis is that the needle-steering device will result in a better success rate of subclavian venous cannulation, at first puncture, compared with the conventional ultrasound-guided technique.


Clinical Trial Description

Central venous catheterization is required in up to two-thirds of intensive care unit patients. Ultrasound-guided placement is now recommended over the "blind" technique to decrease the risk of mechanical complications and duration of the procedure. Although the subclavian site is recommended as first-line because of a lower risk of catheter-related infection and thrombosis (than with internal jugular and femoral sites), this approach is underused (< 20% of regular users). There is also a very low use of ultrasound guidance for subclavian catheterization (< 30% of cases), due to technical difficulties such as more complex visualization of the needle. New magnetic devices theoretically allow better visualization of the needle, a higher success rate and a lower complication rate. In this context, the team performed a prospective randomized simulation trial on a phantom ("reduced torso model"), comparing the standard ultrasound guidance technique with an ultrasound-guided technique assisted by a new needle-steering device in subclavian central venous catheterization (study in progress). The results of this study show a statistically significant improvement in subclavian venipuncture (shorter success time, fewer multiple skin punctures, fewer punctures of the posterior wall of the subclavian vein and needle redirection, greater comfort). These preliminary results argue for a clinical trial of the practical performance of this new device in intensive care unit patients. The hypothesis is that the needle-steering device will result in a higher success rate of subclavian venous cannulation at first puncture compared with the conventional ultrasound guidance technique. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT06050902
Study type Interventional
Source Centre Hospitalier Universitaire de Nimes
Contact Jean-Yves LEFRANT, Pr .
Phone +334.66.68.33.31
Email jean.yves.lefrant@chu-nimes.fr
Status Recruiting
Phase N/A
Start date January 16, 2024
Completion date August 1, 2025

See also
  Status Clinical Trial Phase
Completed NCT02741453 - Bilateral Internal Jugular Veins Ultrasound Scanning Prior to CVC Placement N/A
Completed NCT02939690 - Umbilical Venous Catheter Insertion Depth in Neonates N/A
Completed NCT02661607 - Point of Care Echocardiography Versus Chest Radiography for the Assessment of Central Venous Catheter Placement N/A
Not yet recruiting NCT03442790 - Agitated Saline Versus CXR Confirmation of Central Venous Lines N/A
Not yet recruiting NCT04279808 - Adequate Insertion Depth of Dilator During Central Venous Catheterization N/A
Completed NCT01003366 - Effect of the Bevel Direction of Puncture Needle on Success Rate and Complications During Central Venous Catheterization N/A
Completed NCT03841968 - Dynamic SAX vs Conventional LAX in Internal Jugular Vein Catheterization N/A
Completed NCT01543360 - Comparison of Axillary Versus Subclavian Vein Strategies for Central Venous Catheterization Under Continuous Ultrasound Guidance N/A
Withdrawn NCT03348826 - Study of Sodium Bicarbonate in Restoring Blocked Catheters Phase 2
Recruiting NCT04962945 - Comparison of the Oblique-axis and Long-axis Approaches for Axillary Vein Catheterization Under Ultrasound Guidance N/A
Not yet recruiting NCT06469034 - Mixed Reality and Head-mounted Display for Central Venous Catheterization N/A
Completed NCT04690296 - Ultrasound Guidance Versus Anatomical Landmarks for Subclavian Vein Catheterization N/A
Not yet recruiting NCT02264964 - Duration and Adverse Events of Non-cuffed Catheter in Patients With Hemodialysis N/A
Completed NCT03395691 - Comparison of the Proximal Approach and Distal Approach of Axillary Vein Catheterization Under Ultrasound Guidance N/A
Completed NCT03741946 - Contralateral Head Rotation on Internal Jugular Vein to Carotid Artery Distance and Overlap Ratio N/A
Not yet recruiting NCT04916288 - Needle Puncture Point During Central Venous Catheterization With Ultrasound Guidance
Recruiting NCT05409768 - Comparison of Two Approach in Ultrasound Guided Central Venous Catheterizations N/A
Not yet recruiting NCT06375252 - Evaluation of Central Jugular Vein Catheter Lumen Holder Design and Ergonomic Use N/A