Clinical Trials Logo

Clinical Trial Summary

Ultrasound-guided axillary vein catheterization can be performed via the proximal or distal approach of the axillary vein. The aim of our study is to compare the first puncture success rate and safety between the two approaches of ultrasound-guided axillary vein catheterization in cardiac surgical patients with risk of bleeding.


Clinical Trial Description

For patients after cardiac surgery, antiplatelet drugs or anticoagulants are usually used for preventing thrombosis. Use of those drugs is associated with increased risk of bleeding. Any invasive procedures may put those patients at additional risk of bleeding. Ultrasound (US) has become widely accepted to guide safe and accurate central venous catheterization.The axillary vein in the infraclavicular area is an alternative choice for subclavian vein. Ultrasound images of the infraclavicular axillary vein differ according to its position. Proximal infraclavicular axillary vein is a direct continuation of the subclavian vein. The associated anatomy is simple and the vein is straight and thick in longitudinal axis view, which are in favor of successful puncture. Meanwhile, distal axillary vein also has anatomical advantages for safe and successful cannulations. Distal axillary vein lies further away from the artery and chest wall, and the overlap between distal axillary vein and artery gets greater on moving laterally. It is still unknow that one of the puncture approaches is superior to the other. Until now, there are no studies comparing two puncture approaches in high bleeding risk patients. The aim of the study is to compare the success rate of first puncture and safety of US-guided proximal and distal axillary venous catheterization in cardiac surgery patients with risk of bleeding. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03395691
Study type Interventional
Source Shanghai Zhongshan Hospital
Contact
Status Completed
Phase N/A
Start date February 11, 2018
Completion date September 17, 2019

See also
  Status Clinical Trial Phase
Completed NCT02741453 - Bilateral Internal Jugular Veins Ultrasound Scanning Prior to CVC Placement N/A
Completed NCT02939690 - Umbilical Venous Catheter Insertion Depth in Neonates N/A
Completed NCT02661607 - Point of Care Echocardiography Versus Chest Radiography for the Assessment of Central Venous Catheter Placement N/A
Not yet recruiting NCT03442790 - Agitated Saline Versus CXR Confirmation of Central Venous Lines N/A
Not yet recruiting NCT04279808 - Adequate Insertion Depth of Dilator During Central Venous Catheterization N/A
Completed NCT01003366 - Effect of the Bevel Direction of Puncture Needle on Success Rate and Complications During Central Venous Catheterization N/A
Completed NCT03841968 - Dynamic SAX vs Conventional LAX in Internal Jugular Vein Catheterization N/A
Completed NCT01543360 - Comparison of Axillary Versus Subclavian Vein Strategies for Central Venous Catheterization Under Continuous Ultrasound Guidance N/A
Withdrawn NCT03348826 - Study of Sodium Bicarbonate in Restoring Blocked Catheters Phase 2
Recruiting NCT04962945 - Comparison of the Oblique-axis and Long-axis Approaches for Axillary Vein Catheterization Under Ultrasound Guidance N/A
Not yet recruiting NCT06469034 - Mixed Reality and Head-mounted Display for Central Venous Catheterization N/A
Completed NCT04690296 - Ultrasound Guidance Versus Anatomical Landmarks for Subclavian Vein Catheterization N/A
Not yet recruiting NCT02264964 - Duration and Adverse Events of Non-cuffed Catheter in Patients With Hemodialysis N/A
Recruiting NCT06050902 - Standard Ultrasound Guidance vs. New Needle-steering Device in Subclavian Venous Catheterization N/A
Completed NCT03741946 - Contralateral Head Rotation on Internal Jugular Vein to Carotid Artery Distance and Overlap Ratio N/A
Not yet recruiting NCT04916288 - Needle Puncture Point During Central Venous Catheterization With Ultrasound Guidance
Recruiting NCT05409768 - Comparison of Two Approach in Ultrasound Guided Central Venous Catheterizations N/A
Not yet recruiting NCT06375252 - Evaluation of Central Jugular Vein Catheter Lumen Holder Design and Ergonomic Use N/A