The purpose of the study is to evaluate the impact of arm abduction and adduction on the intravascular electrocardiograph during PICC placement and to find out how arm position influences the catheter tip location by taking postprocedural chest X-ray radiographs.
PICC has been widely applied for therapeutic and nutritional use. In the routine procedure of
PICC placement, for better exposure of the punctured vein and a wider aseptic area, the PICC
set is investigated with the patient's arm abducted in a supine position. While in actual use
of the PICC line, patients commonly prefer a more comfortable position with arm adducted.
Considering the incorporation of the arm position when the catheter is placed and being used,
the effectiveness and safety of the PICC line with the punctured arm adducted are of
practical importance.
This study aims to evaluate the impact of arm abduction and adduction on the intravascular
electrocardiograph (ECG) during ECG-guided PICC placement and to explore how arm movement
(from abduction to adduction) makes an influence on the catheter tip position.
This study is expected to enroll 150 participants. All participants would undergo the
procedure of ECG-guided PICC placement. ECG data will be recorded before the procedure (basal
ECG) and during the procedure with the punctured arm abducted and adducted. After the
procedure, participants will take a post chest X-ray confirmation with arms adducted and
abducted in a supine position. The catheter tip position and influences of arm movements will
be calculated by the distances from the catheter tip to the carina on radiographs.
;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT05299060 -
Effectiveness of Cyanoacrylate Glue in the Fixation of Midline and Peripherally Inserted Central Catheters in Hospitalized Adult Patients: Randomised Clinical Trial (CIANO-ETI)
|
N/A | |
Completed |
NCT00357799 -
VeinViewer for Peripheral IV Placement in Children With Difficult Intravenous (IV) Access
|
Phase 2/Phase 3 | |
Terminated |
NCT00482742 -
Safety & Performance Randomized Study of the CiTop™ Guidewire for Peripheral CTO
|
N/A | |
Recruiting |
NCT03474978 -
Peripherally Inserted Central Catheter Insertion Site and Complication Rate in Neonates
|
N/A | |
Completed |
NCT03563703 -
Transfer of Technological Innovations to Nursing Practice: A Contribution to the Prevention of Infections
|
N/A | |
Completed |
NCT05265481 -
The Effect of Tapping in the Venous Dilatation for Peripheral IV Access
|
N/A | |
Active, not recruiting |
NCT02648334 -
Randomized Comparison of DCB for the Treatment of Superficial Femoral and Popliteal Peripheral Artery Disease
|
N/A | |
Completed |
NCT03148808 -
Natural Vascular Scaffold (NVS) Therapy
|
Phase 1 | |
Completed |
NCT04188262 -
Natural Vascular Scaffold (NVS) Therapy for Treatment of Atherosclerotic Lesions (Activate I)
|
Phase 1 | |
Completed |
NCT04085042 -
Impact of a Multimodal Intervention on Peripheral Venous Catheterization of Cancer Patients
|
N/A | |
Recruiting |
NCT04856826 -
Placement of Peripheral Venous Catheters Under Echo Guidance in a Post-emergency Medical Service
|
N/A | |
Terminated |
NCT01104103 -
Effectiveness Study of the BOA(R)-Constricting IV Band
|
N/A | |
Completed |
NCT00665886 -
Compact Closed System Versus Mounted Open System (COSMOS)
|
Phase 4 | |
Completed |
NCT02769442 -
Prospective, Randomized Controlled Comparison of TERUMO SurFlash Plus Versus BD Insyte Autoguard in an Urban ED
|
N/A | |
Completed |
NCT02795468 -
The Usefulness of Ultrasound Guided Technique Insertion of Radial Artery Catheter in Neonates and Infants
|
N/A | |
Completed |
NCT04001764 -
Comparison of the Efficacy of Radial Artery Catheterization in Three Different Regions in Intensive Care Patients
|
N/A | |
Completed |
NCT03197246 -
Intravascular ECG During Insertion of Peripheral Inserted Central-venous Catheters: Replacement for Chest X-ray?
|
N/A | |
Terminated |
NCT04262947 -
Efficacy of Near-Infrared Vein Imaging for Difficult IV Placement
|
N/A | |
Terminated |
NCT05051020 -
Near-infrared Vein Imaging for Peripheral IV Placement
|
N/A | |
Completed |
NCT06033677 -
Increasing Security With End-zone Arterial Blood Pressure Monitoring During Surgery
|
N/A |