Clinical Trials Logo

Clinical Trial Summary

The purpose of this study is to compare the safety and efficacy of an investigational multifocal intraocular lens (IOL) to an FDA-approved monofocal IOL.


Clinical Trial Description

Participants 21 years and older in need of cataract extraction were consented and randomized in a 1:1 ratio at each investigative site to receive either the AcrySof® IQ ReSTOR® +2.5 D Multifocal IOL Model SN6AD2 [SV25T0] or the AcrySof® IQ Monofocal IOL Model SN60WF in both eyes. Each participant completed a preoperative examination of both eyes, implantation of IOL at the operative visit for each eye, and up to 7 postoperative visits, with monocular testing at Day 1-2, Day 7-14, and Day 30-60, and monocular and binocular testing at Day 120-180 following the second implantation. The first eye to be implanted was considered the primary eye. The second eye was implanted 7 and 30 days of the first. If the first eye was not implanted during surgery, the second eye was not eligible. If the second eye was not implanted during surgery, only the first eye was followed. ;


Study Design

Allocation: Randomized, Intervention Model: Parallel Assignment, Masking: Double Blind (Subject, Outcomes Assessor), Primary Purpose: Treatment


Related Conditions & MeSH terms


NCT number NCT01510717
Study type Interventional
Source Alcon Research
Contact
Status Completed
Phase N/A
Start date February 2012
Completion date December 2012

See also
  Status Clinical Trial Phase
Active, not recruiting NCT06005675 - User Acceptability Evaluation of Pseudophakic Patients Previously Implanted With the TECNIS Odyssey IOL
Active, not recruiting NCT01382641 - Show Improved Vision With the HOYA AF-1 Aspheric Intraocular Lens After Cataract Surgery Phase 4
Completed NCT01382823 - Laser Cataract Surgery With the Femtosecond Laser Technology Phase 4
Completed NCT05991960 - Evaluation of Real-World Data on the Performance of the TECNIS Odyssey™ IOL
Active, not recruiting NCT05574959 - Clinical Investigation of the TECNIS® Next-Generation Intraocular Lens, Model DEN00V N/A
Completed NCT02492659 - Clinical Research of Femtosecond Laser-Assisted Cataract Surgery N/A
Completed NCT01279031 - Randomized Comparison of the Abbott WHITESTAR Signature System With Ellips Tranversal Ultrasound vs. the Alcon Infiniti With the Ozil Torsional Handpiece in Phacoemulsification: A Contralaterally-Controlled Trial Phase 4
Completed NCT00999492 - Selection of Aspheric Diffractive Multifocal Intraocular Lens (IOLS) Based on Corneal Wavefront Phase 4
Completed NCT01061463 - Occupational Cataracts and Lens Opacities in Interventional Cardiology : the O'CLOC Study N/A
Completed NCT01021761 - A Comparison of Prostaglandin E2 (PGE2) Inhibition of Acuvail(Ketorolac 0.45%), Xibrom (Bromfenac 0.09%)and Nevanac (Nepafenac)in Patients Undergoing Phacoemulsification Phase 4
Completed NCT01001806 - A Comparison of Peak Aqueous Penetration of Acuvail (Ketorolac 0.45%), Xibrom (Bromfenac 0.09%), and Nevanac (Nepafenac 0.1%)in Patients Undergoing Phacoemulsification Phase 4
Completed NCT00542581 - Acrysof Toric SN60T3corneal Astigmatism Between 0.75 and 1.00 D. N/A
Completed NCT03708367 - A Post-Market Evaluation of LipiFlow Treatment in Cataract Surgery Practice N/A
Completed NCT05575063 - Clinical Investigation of Healon EndoCoat Ophthalmic Viscosurgical Device (OVD) N/A
Recruiting NCT05531292 - PROOF-OF-CONCEPT STUDY FOR NEW INTRAOCULAR LENS, MODEL C0002 N/A
Completed NCT05058274 - Clinical Results of a Monofocal Aspheric Bitoric Intraocular Lens With Plate Haptics in Hyperopic Eyes (HIPER-AT-TORBI)
Completed NCT05053399 - Evaluation of the TECNIS Symfony® Toric Intraocular Lens N/A
Recruiting NCT02639845 - Eye Drop Application Monitor, Pilot Study N/A
Completed NCT01684007 - A Clinical Outcome Study of Two Multifocal Intraocular Lenses (IOL) in Cataract Patients N/A
Completed NCT00827073 - Comparison of Tetracaine 0.5% and Lidocaine 2% Jelly for Topical Phacoemulsification Cataract Surgery N/A