Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT00231270
Other study ID # P98-5201
Secondary ID
Status Completed
Phase Phase 3
First received October 3, 2005
Last updated April 17, 2008
Start date August 2000
Est. completion date August 2005

Study information

Verified date July 2007
Source Cordis Corporation
Contact n/a
Is FDA regulated No
Health authority United States: Food and Drug Administration
Study type Interventional

Clinical Trial Summary

The primary objective of this study is to compare the safety and effectiveness of the Cordis Nitinol Carotid Stent and Delivery Systems (5.5 F and 7 F) with the ANGIOGUARD XP distal protective device to CEA in the treatment of carotid artery disease in patients at increased risk for surgery.


Recruitment information / eligibility

Status Completed
Enrollment 1300
Est. completion date August 2005
Est. primary completion date
Accepts healthy volunteers No
Gender Both
Age group 18 Years to 80 Years
Eligibility Inclusion Criteria:

1. The patient must be > 18 years of age.

2. The patient has a 50% stenosis (as determined by ultrasound or angiogram) of the common or internal carotid artery and is clinically symptomatic; i.e., within the previous 180 days has experienced symptoms in the ipsilateral carotid artery distribution, defined as:

- one or more TIAs, characterized by distinct focal neurologic dysfunction or monocular blindness with clearing of signs and symptoms within 24 hours, or

- one or more completed strokes (as defined by this protocol) with persistence of symptoms or signs for more than 24 hours (the most recent event is used as the qualifying event), except as excluded below, with stenosis >50%, (as determined by ultrasound or angiogram) of the common or internal carotid artery, OR The patient must have a >80% diameter stenosis (as determined by ultrasound or angiogram) of the internal or common carotid artery without neurological symptoms.

3. To be entered into the study, the patient must have one or more of the following conditions:

- congestive heart failure (class III/IV) and/or known severe left ventricular dysfunction LVEF < 30%

- open heart surgery within six weeks

- recent MI (>24 hours and <4 weeks)

- unstable angina (CCS class III/IV)

- synchronous severe cardiac and carotid disease requiring open heart surgery and carotid revascularization

- Age greater than 80 years as a single risk factor.

Exclusion Criteria:

1. The patient is experiencing an acute ischemic neurologic stroke or has experienced a stroke within the past 48 hours.

2. The patient has an intracranial mass lesion (i.e., abscess, tumor, or infection).

3. The reference segment diameter (distal common carotid and internal carotid artery segment cephalic to the lesion) is less than 4mm or greater than 9mm by quantitative analysis. See Instructions For Use, for proper stent sizing. The exception to this would be with a lesion having >95% stenosis where the true diameter of the distal vessel can not be determined such as the case with a string sign or distal vessel collapse. In this case the judgment of the interventionalist will prevail with the intention not to oversize the stent to the distal vessel by more than 2mm.

4. The patient has known peripheral vascular, supra-aortic or internal carotid artery tortuosity which preclude the use of catheter-based techniques if so randomized.

5. The patient has any intracranial aneurysm (> 9 mm).

Study Design

Allocation: Randomized, Endpoint Classification: Safety/Efficacy Study, Intervention Model: Parallel Assignment, Masking: Open Label, Primary Purpose: Treatment


Related Conditions & MeSH terms


Intervention

Device:
Cordis Nitinol Stent

PRECISE tapered stent

ANGIOGUARD XP Emboli Capture Guidewire (ECGW)


Locations

Country Name City State
n/a

Sponsors (1)

Lead Sponsor Collaborator
Cordis Corporation

References & Publications (2)

Gurm HS, Yadav JS, Fayad P, Katzen BT, Mishkel GJ, Bajwa TK, Ansel G, Strickman NE, Wang H, Cohen SA, Massaro JM, Cutlip DE; SAPPHIRE Investigators. Long-term results of carotid stenting versus endarterectomy in high-risk patients. N Engl J Med. 2008 Apr — View Citation

Yadav JS, Wholey MH, Kuntz RE, Fayad P, Katzen BT, Mishkel GJ, Bajwa TK, Whitlow P, Strickman NE, Jaff MR, Popma JJ, Snead DB, Cutlip DE, Firth BG, Ouriel K; Stenting and Angioplasty with Protection in Patients at High Risk for Endarterectomy Investigator — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary composite of major adverse clinical events including death, any stroke, and/or myocardial infarction at 30-days post-procedure 30-days post-procedure
Primary The same 30-day composite of major adverse clinical events plus death and/or ipsilateral stroke between 31-days and 12-months post-procedure. Between day 31 and 12-months post-procedure.
Secondary successful stent deployment at the target lesion in a variety of carotid morphologies
Secondary successful filter deployment and retrieval
Secondary <30% residual stenosis determined by angiography immediately post-stent placement and post-dilatation
Secondary endovascular access site complications, such as the need for surgical repair or blood transfusion
Secondary surgical site complications, such as wound infection or hematoma, that prolong hospital stay, require incision and drainage, or need blood transfusion
Secondary patency (< 50% restenosis) of the Cordis Nitinol Stent as determined by carotid ultrasound imaging within 48 hours, at six months, and one, two and three years post-procedure
Secondary independent neurologic assessments at 24 + 12 hours, thirty days, six months, and one, two and three years post-procedure (in addition to stroke scales, the development of any cranial nerve deficits will be recorded) - persistent neurologic deficits
Secondary thirty (30)-day and six (6)-month evaluation for disabling stroke Day 30 and 6 months
Secondary six (6)-month, one (1)-year, two (2)-year and three (3)-year composite of major adverse clinical events including death and ipsilateral stroke 6 month and 1, 2, 3yr
Secondary safety assessment of the ANGIOGUARD XP Emboli Capture Guidewire Device
Secondary presence of trapped material as determined by the interventionalist's visual inspection of the ANGIOGUARD XP filter basket following recapture at the completion of the procedure
Secondary laboratory analysis of trapped material contained in the ANGIOGUARD XP filter basket
See also
  Status Clinical Trial Phase
Recruiting NCT02124928 - Morphological and Serological Criteria of Plaque Vulnerability: Risk Assessment for Symptomatic and Asymptomatic Carotid Artery Stenosis N/A
Active, not recruiting NCT01597453 - NOR-SYS: The Norwegian Stroke in the Young Study N/A
Completed NCT00744523 - Proximal Protection With The Mo.Ma Device During Carotid Stenting N/A
Completed NCT00231231 - Carotid Artery Stenting With Emboli Protection Surveillance-Post-Marketing Study (CASES-PMS) Phase 3
Completed NCT00597974 - Neurological Outcome With Carotid Artery Stenting N/A
Completed NCT00587717 - The Acute Effect of Statins on Inflammatory Markers of Athersclerotic Tissue N/A
Completed NCT02536378 - POST-APPROVAL STUDY of TRANSCAROTID ARTERY REVASCULARIZATION in PATIENTS With SIGNIFICANT CAROTID ARTERY DISEASE
Completed NCT02126982 - Salts of Clopidogrel: Investigation to ENsure Clinical Equivalence
Active, not recruiting NCT01445613 - Carotid Artery Stenting Outcomes in the Standard Risk Population for Carotid Endarterectomy N/A
Terminated NCT01414387 - Effects of Cerebral Protection With Filters vs. Flow Reversal on Cerebral Embolization After Carotid Artery Stenting N/A
Completed NCT00403078 - SAPPHIRE Worldwide: Stenting and Angioplasty With Protection in Patients At High-Risk for Endarterectomy
Completed NCT00406055 - CHOICE: Carotid Stenting For High Surgical-Risk Patients Phase 4
Terminated NCT01968226 - TRACER RGD-K5 Carotid Plaque Imaging Study Phase 2
Completed NCT01685567 - Safety and Efficacy Study for Reverse Flow Used During Carotid Artery Stenting Procedure Phase 3
Completed NCT00402740 - Protected Carotid Artery Stenting in Subjects at High Risk for Carotid Endarterectomy (CEA) (PROTECT) N/A
Completed NCT00287508 - Emboshield® and Xact® Post Approval Carotid Stent Trial (The EXACT Study) Phase 4
Completed NCT00178672 - A Single Center of Carotid Stenting With Distal Protection for the Treatment of Obstructive Carotid Artery Disease Phase 4
Recruiting NCT02850588 - SVS VQI TransCarotid Revascularization Surveillance Project
Completed NCT02759653 - Norwegian Carotid Plaque Study
Withdrawn NCT01042912 - Frequency Analysis of Carotid Artery Disease N/A