Clinical Trials Logo

Clinical Trial Summary

The purpose of this study is to compare the MRI results with the new SPECT image reconstruction method, this study will allow us to determine whether a new more accurate method of looking at the heart by nuclear study can be used in routine clinical use.


Clinical Trial Description

Currently, up to one-third of all nuclear medicine studies are performed for cardiovascular disorders, and mostly are myocardial perfusion imaging (MPI) using SPECT acquisition. MPI aims at detection of acute myocardial ischemia and the scarred myocardium and it is increasingly used to plan myocardial revascularization and to assess the effectiveness of medical and surgical interventions. However, nonuniform gamma-ray attenuation in the thoracic region may severely impair the accuracy of SPECT cardiac imaging and frequently result in image artifacts. Therefore, attenuation corrected must be applied. We have derived an algorithm (called EM-IntraSPECT) that is able to reconstruct tomographic cross-sections of a patient from SPECT studies alone. The reconstructed cross-sections in turn, may be used for attenuation correction of cardiac SPECT images thus improving quality analysis based of these images. In this research we intend to continue evaluation of the new attenuation compensation algorithm and to assess the clinical usefulness of this method. These goals can be reached by comparing the patient's cross sectional anatomical data reconstructed by EM-IntraSPECT and obtained from MRI. It is proposed that 10 patients already undergoing nuclear cardiac imaging for clinical purpose, with 99mTc sestamibi or 99mTc radiolabeled red cells will be selected. These patients would be utilized to reconstruct transmission images and determination of internal anatomical structures in the thoracic region from SPECT projections alone. Further, direct and quantitative comparison of the patient's anatomy obtained by the MRI and the SPECT methods will be performed. The same algorithm would be used for reconstruction of attenuation compensated emission SPECT cardiac images. Finally, the accuracy and the clinical usefulness of this new, attenuation corrected cardiac SPECT image reconstruction would be quantitatively evaluated. All these procedures apply only to the image data and NOT the patient. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT00639704
Study type Observational
Source State University of New York - Upstate Medical University
Contact
Status Completed
Phase
Start date January 1996
Completion date August 2011

See also
  Status Clinical Trial Phase
Completed NCT04585568 - Validation of Ballistocardiographic Biosensors and Other Hemodynamic Measures for Healthy Subjects
Withdrawn NCT05084391 - Phase I/II Randomized Study of Stereotactic Ablative Radiotherapy (SABR) Versus Standard of Care for Refractory Structural Cardiac Arrhythmias (SABR-HEART) Phase 1/Phase 2
Recruiting NCT02798068 - Steroids and Microcirculation In Cardiac Surgery Phase 4
Recruiting NCT01598766 - General Investigative MRI Protocol Phase 1
Not yet recruiting NCT03047876 - Brain Vascular Reactivity to Hypothermic Circulatory Arrest With Antegrade Cerebral Perfusion During Aortic Arch Surgery
Recruiting NCT05297877 - Use of Artificial Intelligence Cardiac Ultrasound Technology in Teaching Point of Care Cardiac Ultrasound N/A
Completed NCT04024982 - TEE Training for Anaesthesiologists N/A
Completed NCT04096781 - Engaging Patients to Help Achieve Increased Patient Choice and Engagement for AFib Stroke Prevention N/A