Clinical Trials Logo

Clinical Trial Details — Status: Withdrawn

Administrative data

NCT number NCT01911117
Other study ID # A-ER-102-080
Secondary ID
Status Withdrawn
Phase
First received
Last updated
Start date June 2012
Est. completion date December 2012

Study information

Verified date June 2018
Source National Cheng-Kung University Hospital
Contact n/a
Is FDA regulated No
Health authority
Study type Observational

Clinical Trial Summary

In one previous study, esCCO was compared with continuous thermodilution CO (TDCO), measurements in 36 postoperative cardiac surgery patients, showing a bias (mean difference) of -0.06 and a precision (1 SD) of 0.82 L/min. In addition, esCCO was compared with intermittent bolus TDCO, showing a correlation coefficient of 0.82 (P < 0.001, n = 24), a bias of -0.63, and a precision of 1.01 L/min (n = 119). The results of clinical use of esCCO suggest that its measurement accuracy is comparable to the thermodilution method in general population. However, no any intraoperative comparison for cardiac surgery patients was reported before. This study is designed for the accuracy in the patients undergoing cardiac surgery.

Specific aims:

1. To investigate the correlation of esCCO and the traditional CO measurement in cardiac surgical patients.

2. To investigate the intraoperative t accuracy of time point between ecCCO and traditional CO measurement for patients undergoing bypass cardiac surgery.


Description:

Determination of cardiac output (CO) is often desirable for assessing a patient's hemodynamic condition during the surgery requiring cardiopulmonary bypass. However, the current methods of continuous CO measurement are still based on invasive technique, such as thermodilution via pulmonary artery catheter (Swan-Ganz), transpulmonary thermodilution via PiCCO kit, or pulse contour analysis via arterial line (FloTrac or PiCCO). Noninvasive CO measurement to all patients is currently impractical, because most measurement methods available are based on invasive techniques. However, two developing trends for this kind of monitor had occurred. There are one shifting toward noninvasive technologies and the other trend toward continuous measurement rather than intermittent measurement. Therefore, continuous CO (CCO) monitoring with less invasive would be desirable.

The pulse contour method is one of the technologies used for min-invasive monitoring of CO. It is based on the relationship between arterial blood pressure and stroke volume and has been greatly improved since early 1950s. Arterial waveform-based CO is frequently used in current medical practice, but it still requires arterial puncture. Pulse wave transit time has been proven to have good correlation with stroke volume. Pulse wave transit time consists of a pre-ejection period, pulse wave transit time through the artery, and pulse wave transit time through the peripheral arteries, which compensates for the effect of changes in systemic vascular resistance (SVR). Based on the relationship between pulse wave transit time and stroke volume, the noninvasive device, estimated CCO (esCCO), via measuring electrocardiogram (ECG), pulse oximeter wave, and arterial blood pressure had been developed by Sugo et al.. It has the great advantage to simplify CO measurement by combining the results of these familiar noninvasive monitoring techniques. Thus, it may be a useful technique for optimizing medical treatment.

In one previous study, esCCO was compared with continuous thermodilution CO (TDCO), measurements in 36 postoperative cardiac surgery patients, showing a bias (mean difference) of -0.06 and a precision (1 SD) of 0.82 L/min. In addition, esCCO was compared with intermittent bolus TDCO, showing a correlation coefficient of 0.82 (P < 0.001, n = 24), a bias of -0.63, and a precision of 1.01 L/min (n = 119). The results of clinical use of esCCO suggest that its measurement accuracy is comparable to the thermodilution method in general population. However, no any intraoperative comparison for cardiac surgery patients was reported before. This study is designed for the accuracy in the patients undergoing cardiac surgery.

Specific aims

1. To investigate the correlation of esCCO and the traditional CO measurement in cardiac surgical patients.

2. To investigate the intraoperative t accuracy of time point between ecCCO and traditional CO measurement for patients undergoing bypass cardiac surgery.


Recruitment information / eligibility

Status Withdrawn
Enrollment 0
Est. completion date December 2012
Est. primary completion date December 2012
Accepts healthy volunteers No
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria:

1. Patients undergo cardiac surgery and are over 18 years of age.

2. Patients need bypass machine for their cardiac surgery and traditional CO measurement.

3. Patients who are competent to understand the study and provide written informed consent and participate in outcome measurements.

Exclusion Criteria:

- Patients are over 75 years of age. Patients are unable to read or write the informed consent, any condition that could interfere with the interpretation of outcome assessments, pregnant or lactating women. Patient with marked arrhythmias, those preoperatively receiving treatment with intra-aortic balloon bump (IABP) will also not be included.

Study Design


Related Conditions & MeSH terms


Locations

Country Name City State
Taiwan National Cheng Kung University Hospital Tainan City Shengli Rd

Sponsors (1)

Lead Sponsor Collaborator
National Cheng-Kung University Hospital

Country where clinical trial is conducted

Taiwan, 

Outcome

Type Measure Description Time frame Safety issue
Primary The correlation of esCCO and the traditional CO measurement in cardiac surgical patients. Comparison Between esCCO and Thermodilution Measurements of CO for cardiac surgical patients.
Check the accuracy of esCCO in cardiac surgical patients. It should be well correlated before bypass but will be inaccurate when partial bypass once start. When bypass procedure start to rewarm, it will be accurate initially but gradually well correlated within temperature corrected or heart function become normal again.
18 months
See also
  Status Clinical Trial Phase
Recruiting NCT05054179 - Pecto-Intercostal Fascial Plane Block Catheter Trial for Reduction of Sternal Pain Phase 2/Phase 3
Completed NCT04051021 - Non-Pharmacological Interventions on Patient Experience and Healthcare Utilization in Adult Cardiac Surgery Patients N/A
Recruiting NCT04604886 - The Consistency of Cardiac Output Measured by Pulmonary Artery Catheter and LiDCO in Cardiac Surgical Patients N/A
Recruiting NCT04075981 - Prevention Atrial Fibrillation by BOTulinum Toxin Injections (BOTAF) Phase 3
Completed NCT04062396 - Comparison of Remowell 2 and Inspire on Delirium and Cognitive Dysfunction N/A
Recruiting NCT04709705 - DMSO Cryopreserved Platelets in Cardiopulmonary Bypass Surgery (CRYPTICS) Phase 2/Phase 3
Not yet recruiting NCT05563662 - SURgical Registry of ENDocarditis EuRope
Withdrawn NCT03289104 - Improving Sternal Healing After Cardiac Surgery: Sternal Wire vs ZIPFIX N/A
Completed NCT02964026 - Study of Clinical Outcomes Associated With the Pulmonary Artery Catheter (PAC) in Cardiac Surgery Patients N/A
Completed NCT03563196 - Diagnosis Of Pulmonary Complications After Cardiac Surgery In Children
Completed NCT04199039 - Effects of Endotracheal Tube Fixation Methods on Hemodynamic Parameters During Endotracheal Suction N/A
Completed NCT02471001 - The Levels of Anaesthetics in Heart Muscle During Heart Surgery N/A
Completed NCT02325726 - RRI Compared With NephroCheckTM to Predict Acute Renal Failure After Cardiac Surgery. N/A
Completed NCT01246947 - Tricuspid Annuloplasty for Moderate Tricuspid Regurgitation Associated With Miral Operation N/A
Completed NCT01151254 - Comparison of Propofol Based Versus Volatile Based Anesthesia and Postoperative Sedation N/A
Completed NCT00821262 - Sevoflurane in Cardiac Surgery Phase 4
Completed NCT00996099 - Continuous Glucose Monitoring Combined With Computer Algorithm for Intensive Insulin Therapy in Cardiosurgical Patients N/A
Completed NCT00617955 - Effects of Aprotinin During Cardiac Surgery/Long Term Death Rates N/A
Completed NCT00337805 - Double Blind Randomized Trial of Saline vs Pentaspan for Resuscitation After Cardiac Surgery Phase 2/Phase 3
Completed NCT00336466 - The Erythropoietin NeuroProtective Effect: Assessment in CABG Surgery (TENPEAKS) Phase 2