This is a prospective, multi-site, non-randomized, data collection study. The purpose of this study is to investigate the correlation between pacing sites and ECG morphology or pacing parameters during left bundle branch pacing (LBBP) and perform the use condition analysis to assess the long-term performance of pacing lead during LBBP.


Clinical Trial Description

His bundle pacing (HBP) is a physiological pacing, but also has some limitations, including high and unstable pacing threshold in 5-10% patients, low R-wave amplitude causing inappropriate pacing management, damage to the His bundle during implantation. On the other hand, left bundle branch pacing (LBBP), achieved via trans-ventricular septal approach with the pacing lead tip at the left side of the ventricular septum, has recently initiated and been widely practiced in China because of easy implantation, relatively narrow paced QRS duration, low and stable pacing threshold, high R wave amplitude, and the LBBB correction by a low pacing output. As LBBP is in the early phase of clinical practice in China, in order to better conduct LBBP implantation and understand mechanisms of LBBP therapy, physicians often do imaging assessment of the pacing lead in patients implanted with LBBP based on clinical necessity. Additionally, there is no report of mid/long-term correlation between lead location and ventricular electrical activity, nor mid/long-term pacing lead performance assessment during LBBP. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04119323
Study type Observational
Source Medtronic Cardiac Rhythm and Heart Failure
Contact
Status Completed
Phase
Start date September 24, 2019
Completion date July 14, 2020

See also
  Status Clinical Trial Phase
Recruiting NCT05557006 - Change of QRS Morphology and Electrophysiological Characteristics During Pacing Within the Interventricular Septum
Completed NCT00949715 - Optimize RV Follow-up Selective Site Pacing Clinical Trial N/A
Recruiting NCT04595487 - LVSP vs RVP in Patients With AV Conduction Disorders N/A
Terminated NCT00858559 - Follow-up of Patients With Implantable Cardioverter Defibrillators by Home Monitoring (ANVITE) N/A
Completed NCT04023890 - Ventricular Electrical Synchronization by Stimulating Left and Right Bundle Branches Area in Pacing-indicated Patients
Completed NCT00621491 - Prevention of Venous Thrombosis After Permanent Transvenous Leads Implantation N/A
Completed NCT04738396 - Electrogram and Hemodynamic Characteristics of Adaptive LBBAP in Patients With Heart Failure or Bradycardia
Completed NCT01755143 - Evaluation of Approved Pacing Lead (Model 5076) for Use in MRI Environment N/A