Clinical Trials Logo

Clinical Trial Summary

This is a prospective, single-site, non-randomized, acute feasibility clinical study. The purpose of this study is to explore the electrocardiogram (ECG) characteristics of simultaneous stimulation of right and left bundle branches area.


Clinical Trial Description

Many pacemaker patients have cardiac conduction system disease and thus need ventricular pacing. Traditional ventricular pacing causes ventricular dyssynchrony that in turn causes cardiac contraction dysfunction. CRT pacing provides better ventricular synchronization, but not the optimal, especially in patients with narrow QRS. CRT non-response rate is at 30%. His bundle pacing utilizes naturel His bundle-Purkinjie system to provide optimal physiological pacing. But many pacing-indicated patients have abnormal His bundle-Purkinje system, thus His bundle pacing cannot provide optimal pacing in patients with abnormal cardiac conduction system. Moreover, the pacing threshold is high during His bundle pacing. More recently, left bundle branch pacing is proposed. However, LBBP will generate right bundle branch block pattern, another kind of weak ventricular synchronization. Thus, the investigators propose to excite the left and right bundle branches area simultaneously to normalize ventricular synchronization. The purpose of this study is to explore the electrocardiogram (ECG) characteristics of simultaneous stimulation of right and left bundle branches area. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04023890
Study type Observational
Source Medtronic Cardiac Rhythm and Heart Failure
Contact
Status Completed
Phase
Start date January 14, 2019
Completion date January 31, 2020

See also
  Status Clinical Trial Phase
Recruiting NCT04870424 - Colchicine for Patients With Aortic Stenosis Undergoing Transcatheter Aortic Valve Replacement Phase 3
Completed NCT02548819 - University Hospital Cardiac Device MR Registry: The Safety of MR Imaging in Patients With Implanted Cardiac Devices N/A
Recruiting NCT03636230 - Remote Patient Management of CIEDs - Brady Devices N/A
Terminated NCT03859167 - Study of the Loss of AV Synchrony at Maximum Exercise
Completed NCT00832988 - CONFIRM - Comparison of in Office Interrogation Versus Remote Measurements
Completed NCT00294034 - VIBRANT Registry: Value of Information Based From Pacemaker Recordings and New Technologies N/A
Recruiting NCT05623527 - Acute Cerebrovascular Events Secondary to Patients Receiving Cardiac Electronic Implants
Completed NCT03847298 - Evaluation of Physical Fitness and Physical Activity Levels of Pediatric Arrhythmia Patients With Pacemaker
Completed NCT03843242 - Evaluation of Ventricular Pacing Suppression Algorithms in Dual Chamber Pacemaker N/A
Active, not recruiting NCT01138670 - Complications Following Pacemaker or Implantable Defibrillator Cardioverter (ICD) Implantation in Denmark N/A
Completed NCT00307073 - Adapta Pacing System Clinical Study N/A
Completed NCT04958369 - Ultrasound-guided Axillary Versus Conventional Cephalic Venous Access for Implantation of Cardiac Devices N/A
Completed NCT01459874 - Evaluation of an Organizational Model for Remote Monitoring of Pacemaker and Implantable Cardioverter Defibrillator Recipients N/A
Completed NCT00631709 - REmote MOnitoring Transmission Evaluation of IPGs Phase 4
Recruiting NCT06356207 - Syncope-Asystole Latency Time in Tilt Table Test: The SALT-TILT Study
Completed NCT03052829 - Physical Activity and Pacemaker Study N/A
Completed NCT00491777 - Correlation Research Study: IQ2, NcIQ and IQ101 Phase 1
Active, not recruiting NCT05361681 - EMI and CIED: Is High Power Charging of Battery Electric Car Safe? N/A
Recruiting NCT04201015 - Optimising Pacing for Contractility 2 Phase 2/Phase 3
Recruiting NCT03061747 - Multi-centre Observational Registry on Patients With Implantable Devices Remotely Monitored N/A