Clinical Trials Logo

Clinical Trial Summary

The use of cardiac output monitoring to guide intraoperative fluid management and inotropic drugs as part of a hemodynamic therapy algorithm reduce the complication rate in major abdominal surgery. The FloTrac/Vigileo system (© Edwards Lifesciences) (Edwards Lifesciences, Irvine, CA) device estimate cardiac output by using arterial pulse contour analysis. The accuracy of FloTrac/Vigileo have been proven in patients with normal cardiac index. Most of studies regarding FloTrac/Vigileo were performed in patients in horizontal supine position, which is not usually the reality in the operation theater during abdominal surgery. Therefore, the investigators realized this monocentric prospective clinical trial to study the accuracy and trending ability of the fourth generation FloTrac/Vigileo system cardiac output estimation in three different positions (horizontal supine, Trendelenburg and reverse Trendelenburg positions) in anesthetized patients undergoing elective major abdominal surgery. The reference method of cardiac output measurement used was the transesophageal echocardiography.


Clinical Trial Description

n/a


Study Design


Related Conditions & MeSH terms


NCT number NCT05508711
Study type Observational
Source Université Libre de Bruxelles
Contact
Status Completed
Phase
Start date October 1, 2021
Completion date June 30, 2022

See also
  Status Clinical Trial Phase
Recruiting NCT04604886 - The Consistency of Cardiac Output Measured by Pulmonary Artery Catheter and LiDCO in Cardiac Surgical Patients N/A
Completed NCT04044157 - Cardiac Output in Children During Anesthesia
Not yet recruiting NCT01678066 - A Prospective Study to Bilaterally Compare a Non-Invasive Cardiac Output Monitor N/A
Completed NCT01001533 - Assess the Ability of Electrical Cardiometry to Trend Hemodynamic Variables During Dexmedetomidine Sedation N/A
Recruiting NCT04926220 - Dynamic Estimation of Cardiac Output in the Operating Room
Not yet recruiting NCT06007196 - Evaluation of Non-invasive Continuous Hemodynamic Measurement From Task Force CORE
Recruiting NCT05648279 - Personalized Hemodynamic Management in High-risk Major Abdominal Surgery N/A
Recruiting NCT06090396 - Non-invasive Cardiac Index in Children
Completed NCT02438228 - Cardiac Output by Nine Different Pulse Contour Algorithms N/A
Withdrawn NCT00783679 - The Feasibility and Accuracy of Exhaled CO2 to Measure Cardiac Output in Ventilated Patients Without Tracheal Intubation N/A
Completed NCT00996190 - Best Regimen for Phenylephrine Administration During Cesarean Section Phase 4
Active, not recruiting NCT04465201 - The Smart Pump Study N/A
Completed NCT05779683 - Caretaker in the Cardiovascular Intensive Care Unit (CVICU)
Completed NCT04112719 - Assessing Effects of Lateral Tilt on Cardiac Output Using a Non-invasive Technique
Recruiting NCT02156856 - Stroke Volume Analysis During Aortic Valve Replacement Trial N/A
Recruiting NCT01781260 - Effect of Prone Position on Liver Blood Flow and Function N/A
Terminated NCT00920569 - Recirculation, Oxygenator Blood Volume and Cardiac Output Measurements During Extracorporeal Membrane Oxygenation N/A
Recruiting NCT06114147 - Cardiac Flow Measurements in Pregnant Women by Non Invasive Techniques N/A
Completed NCT05365113 - Comparison of Hemodynamic Effects of Two Modalities of Alveolar Recruitment Maneuvers in Major Abdominal Surgery Patients N/A
Completed NCT02737813 - Cardiac Output Changes During Hyperbaric and Isobaric Bupivacaine in Patients Undergoing Cesarean Section Phase 4