Cardiac Output Clinical Trial
Official title:
Measurement of Cardiac Output in Intensive Care Unit With Unstable Hemodynamic: Validation of Physioflow® Device Versus Trans Thoracic Echocardiography
Physioflow® is a new device for measuring cardiac output in a non-invasive way using a thoracic bioimpedance technique. This technique has been validated in patients in stress tests as well as in Chronic Obstructive Pulmonary Disease (COPD) patients, in obese patients and in children. Very little work has been published in intensive care unit (ICU) and no studies have been done on hemodynamically unstable patients. The aim of this work is to compare the cardiac output measured by Physioflow® to the transthoracic echocardiography (TTE) in ventilated, sedated patients hospitalized in ICU receiving catecholamines and for whom the attending physician wants to evaluate the fluid responsiveness using the TTE and a passive leg raising maneuver (PLR).
All patients included will be simultaneously monitored with TTE and the Physioflow® thoracic electrical bioimpedance device. Cardiac output is measured by the Physioflow® Thoracic Bioimpedance Device and TTE before and after PLR. If the attending physician decide to administer fluid expansion a new set of cardiac output measurement will be performed before and after the volume expansion. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT04604886 -
The Consistency of Cardiac Output Measured by Pulmonary Artery Catheter and LiDCO in Cardiac Surgical Patients
|
N/A | |
Completed |
NCT04044157 -
Cardiac Output in Children During Anesthesia
|
||
Not yet recruiting |
NCT01678066 -
A Prospective Study to Bilaterally Compare a Non-Invasive Cardiac Output Monitor
|
N/A | |
Completed |
NCT01001533 -
Assess the Ability of Electrical Cardiometry to Trend Hemodynamic Variables During Dexmedetomidine Sedation
|
N/A | |
Recruiting |
NCT04926220 -
Dynamic Estimation of Cardiac Output in the Operating Room
|
||
Not yet recruiting |
NCT06007196 -
Evaluation of Non-invasive Continuous Hemodynamic Measurement From Task Force CORE
|
||
Recruiting |
NCT05648279 -
Personalized Hemodynamic Management in High-risk Major Abdominal Surgery
|
N/A | |
Recruiting |
NCT06090396 -
Non-invasive Cardiac Index in Children
|
||
Completed |
NCT05508711 -
Comparability of Transesophageal Echocardiography and FloTrac/Vigileo System Three Different Positions
|
||
Completed |
NCT02438228 -
Cardiac Output by Nine Different Pulse Contour Algorithms
|
N/A | |
Completed |
NCT00996190 -
Best Regimen for Phenylephrine Administration During Cesarean Section
|
Phase 4 | |
Withdrawn |
NCT00783679 -
The Feasibility and Accuracy of Exhaled CO2 to Measure Cardiac Output in Ventilated Patients Without Tracheal Intubation
|
N/A | |
Active, not recruiting |
NCT04465201 -
The Smart Pump Study
|
N/A | |
Completed |
NCT05779683 -
Caretaker in the Cardiovascular Intensive Care Unit (CVICU)
|
||
Completed |
NCT04112719 -
Assessing Effects of Lateral Tilt on Cardiac Output Using a Non-invasive Technique
|
||
Recruiting |
NCT01781260 -
Effect of Prone Position on Liver Blood Flow and Function
|
N/A | |
Recruiting |
NCT02156856 -
Stroke Volume Analysis During Aortic Valve Replacement Trial
|
N/A | |
Terminated |
NCT00920569 -
Recirculation, Oxygenator Blood Volume and Cardiac Output Measurements During Extracorporeal Membrane Oxygenation
|
N/A | |
Recruiting |
NCT06114147 -
Cardiac Flow Measurements in Pregnant Women by Non Invasive Techniques
|
N/A | |
Completed |
NCT05365113 -
Comparison of Hemodynamic Effects of Two Modalities of Alveolar Recruitment Maneuvers in Major Abdominal Surgery Patients
|
N/A |