Cardiac Diseases Clinical Trial
Official title:
Quarter-Time Myocardial Perfusion SPECT
A new, innovative software image processing method, wide beam reconstruction (WBR), utilizes resolution recovery and incorporates Poisson noise-reduction into the reconstruction process of NM images. This method facilitates the reconstruction of low count density myocardial perfusion SPECT images. Preliminary research indicates that SPECT acquisition time consequently can be reduced by 60% (less than 5 minutes) for rest and by 75% (just over 3 minutes) for stress, while tomographic image quality is maintained, or even improved. Such a decrease in image acquisition time decreases patient discomfort during the tomographic acquisition, decreases the opportunity for patient motion, and improves laboratory efficiency.
Standard full-time SPECT will be processed using FBP and compared to 3-minute stress and 5-minute rest scans processed with WBR. The following scan parameters will be evaluated: image quality; perfusion defect extent, severity, and reversibility; transient ischemic dilatation; left ventricular end-diastolic volume; left ventricular end-systolic volume; left ventricular ejection fraction; and regional wall motion and wall thickening abnormalities. These parameters will be assessed visually by experienced Nuclear physicians (at least 2 blinded readers) and quantitatively using several different commercially available software programs. ;
Observational Model: Case Control, Time Perspective: Retrospective
Status | Clinical Trial | Phase | |
---|---|---|---|
Terminated |
NCT00176657 -
The Use of HEMOBAG to Salvage Blood After Cardiac Surgery
|
Phase 2 | |
Completed |
NCT00027001 -
Qigong Therapy For Heart Device Patients
|
N/A | |
Terminated |
NCT04398017 -
MEOPA-coupled Hypnosis Versus MEOPA-standard Care in Transesophageal Echocardiography
|
N/A | |
Completed |
NCT00296738 -
123I-MIBG SPECT/CT for Assessment of Cardiac Sympathetic Innervation
|
Phase 0 | |
Completed |
NCT00293592 -
Dexamethasone for Cardiac Surgery Trial
|
N/A | |
Completed |
NCT01080781 -
Ephrin B1 Regulation in Human Right Appendage
|
N/A | |
Completed |
NCT00011310 -
Cardiopulmonary Effects of Particulate Exposure
|
N/A | |
Completed |
NCT02727634 -
Ultrapower; a Minimally Invasive Tool for Evaluation of Total Cardiac Power
|
N/A | |
Completed |
NCT01639313 -
Comparison of Nexfin Pulse Contour Analysis and Cardiac Magnetic Resonance Imaging for the Measurement of Cardiac Output
|
N/A | |
Completed |
NCT00945048 -
Non-Invasive Determination of Cardiac Output by Electrical Velocimetry
|
N/A | |
Completed |
NCT00281424 -
Increasing Walking Following Cardiac Rehabilitation
|
Phase 2/Phase 3 | |
Not yet recruiting |
NCT06409481 -
Pharmacovigilance Assessment of Reporting of Cardiovascular Adverse Events With Antineoplastic Agents (PARCA)
|
||
Completed |
NCT02723890 -
The Efficacy and Safety of Using the Novel Tyto Device
|
N/A | |
Completed |
NCT01165515 -
Endostatin Serum Levels During Bicycle Stress Test
|
N/A | |
Recruiting |
NCT05051254 -
Respiratory Muscles and Work of Breathing in Children
|
N/A | |
Completed |
NCT01683448 -
The Effect of Perioperative Medications on the Outcomes of Patients Undergoing Cardiac Surgery
|
||
Terminated |
NCT00229892 -
Incisions for Cardiac Surgery
|
N/A | |
Completed |
NCT02802254 -
Increasing Risk Perception of Physical Activity Using Patient-targeted Feedback.
|
Phase 2/Phase 3 | |
Completed |
NCT02159014 -
DanceFit Prime: A Dance Based Physical Activity and Nutritional Intervention for Primary Care - A Feasibility Study
|
N/A | |
Completed |
NCT00479804 -
Non-Invasive Determination of Cardiac Output by Inertgas Rebreathing Method
|
N/A |