Clinical Trials Logo

Clinical Trial Summary

Successful radio frequency (RF) cardiac catheter ablation requires the creation of lesions by delivering energy while maintaining adequate catheter contact with the endocardium. Unfortunately, it is difficult to identify contact intraoperatively as a typical RF ablation catheter lacks clear indications of contact. We propose to use the Boston Scientific IntellaTip MiFi catheter to explore whether characteristics of the electrograms produced by the mini-electrodes on the ablation tip could help confirm tissue contact. Using an ultrasound catheter to define instances of clear contact and non-contact, we will determine whether the micro-electrodes produce sufficient information to confirm catheter contact. We propose that the MiFi catheter produces sufficient signal characteristics that can be used as an effective surrogate for adequate tissue contact.


Clinical Trial Description

n/a


Study Design

Endpoint Classification: Efficacy Study, Intervention Model: Single Group Assignment, Masking: Open Label, Primary Purpose: Diagnostic


Related Conditions & MeSH terms


NCT number NCT02080975
Study type Interventional
Source Emory University
Contact
Status Completed
Phase N/A
Start date March 2014
Completion date December 2015

See also
  Status Clinical Trial Phase
Recruiting NCT05416086 - iCLAS™ Cryoablation System Post-Market Clinical Follow-up (PMCF) Study N/A
Terminated NCT02317029 - Comparison of Oxygen Interventions and Defibrillator Efficiency N/A
Recruiting NCT01563848 - Cryoablation in Patients With Atrial Flutter Phase 2
Completed NCT01229254 - Evaluate the Pharmacokinetics and Safety of MK-4448 in Participants With Nonvalvular Atrial Fibrillation or Atrial Flutter Phase 2
Completed NCT02065388 - Pharmacogenetic Dosing of Warfarin Phase 3
Completed NCT00839657 - Clarification of Optimal Anticoagulation Through Genetics Phase 3
Completed NCT00232232 - Use of Fish Oils to Prevent Atrial Mechanical Stunning and Atrial Remodeling Due to Atrial Arrhythmia Phase 4
Completed NCT04884100 - enHEART - Exploring Full Content of Optical Signals to Enhance Cardiac Arrhythmia Screening N/A
Completed NCT05468281 - RAFF5 Proposal: Improve the Quality and Safety of Patients Seen in the Emergency Department for Acute Atrial Fibrillation and Flutter
Completed NCT03627143 - Decreasing Hospital Admissions From the ED for AAFF N/A
Completed NCT02917538 - A Randomized Trial of Contact Force in Atrial Flutter Ablation N/A
Enrolling by invitation NCT05903313 - A Study to Evaluate Accuracy and Validity of the Chang Gung ECG Abnormality Detection Software
Recruiting NCT05755074 - Ablation of Typical Right Atrial Flutter N/A
Recruiting NCT05883631 - RESOLVE-AF: Clinical Evaluation of the Ablacath™ Mapping Catheter and Ablamap® System Utilizing Electrographic Flow (EGF) Mapping to Resolve Extra-PV Sources of Atrial Fibrillation and Guide Ablation Therapy. N/A
Recruiting NCT03272620 - Atrial Fibrillation at the Viennese University Emergency Department N/A
Completed NCT02810938 - MIFI Flutter Registry - Ablation of Atrial Flutter With IntellaTip Sensor Technology
Recruiting NCT02591875 - Atrial Flutter Ablation in a Real World Population N/A
Completed NCT01914497 - Dipole Density Mapping of Typical Atrial Flutter N/A
Completed NCT02268799 - High Sensitivity Troponin T Levels Following DC Cardioversion for Atrial Fibrillation / Atrial Flutter N/A
Active, not recruiting NCT01976507 - Use of Dabigatran Etexilate to Prevent Stroke and Thromboembolism Phase 4