Cardiac Arrhythmia Clinical Trial
Official title:
Hemodynamics Measurement in Radiofrequency Catheter Ablation
This study will occur in patients undergoing routine cardiac ablation of his/her arrhythmia with planned use of an irrigated ablation catheter. The main objective of this study is to take intracardiac pressure measurements and pressure waveforms with both a "gold standard" balloon tipped pulmonary artery catheter placed for this study and an irrigated ablation catheter placed as standard of care for the procedure.
Measuring internal heart pressures allows for the assessment and diagnosis of a variety of cardiac conditions which are commonly found in patients undergoing catheter ablation, including congestive heart failure, diastolic dysfunction, and valvular heart disease. Currently it is unknown if taking pressure measurements with the ablation catheter is accurate and it is not standard practice to insert the additional 'gold standard' pressure sensing catheter. Catheter ablation of cardiac arrhythmia is performed to offer symptomatic relief from a variety of atrial, ventricular and atrio-ventricular rhythms. Irrigated ablation catheters are commonly used for ablation of arrhythmias arising from the left heart and coronary sinus. These catheters contain internal channels allowing for infusion of an external fluid directly to the tip of the catheter, where the fluid is sprayed through numerous end holes allowing for cooling of the catheter ablation tip. Fluid filled catheters are also the primary tool utilized to assess intravascular and intracardiac pressures and hemodynamics in the cardiac catheterization suite and intensive care unit. However, the fluid filled catheters commonly used for these assessments are single lumen with a single end hole and generally have a larger minimal diameters compared to the ablation catheter. "Dampening" of pressure waveforms are observed in smaller diameter catheters and may lead to underestimation of peak pressure and overestimation of the nadir pressure gradient. It is unknown if transduction of pressures from the tip of an irrigated ablation catheter will yield equivalent results compared to use of a single 5 French (5F) sized lumen catheter. This study will seek to enroll patients already scheduled to have a cardiac ablation for a clinical arrhythmia at Emory University Hospital. After completion of the standard ablation, the ablation catheter will be positioned in the heart and pressures will be measured. Next, a standard pressure sensing catheter will be positioned in the same area in the heart and pressures will be measured. The pressure values for each heart chamber assessed will be compared between the catheters. The purpose of this study is to test the hypothesis that transduction of intracardiac pressures using an irrigated ablation catheter placed as standard of care for the ablation procedure is equivalent to transduction of pressures using a standard 5F balloon tipped PA catheter placed only for this research study. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT05067114 -
Solutions for Atrial Fibrillation Edvocacy (SAFE)
|
||
Completed |
NCT02241252 -
Using an iPhone ECG to Monitor the QT Interval on Dofetilide and Sotalol Patients
|
N/A | |
Completed |
NCT01428778 -
Berlin Beat of Running Study
|
N/A | |
Completed |
NCT01626261 -
Examination of Implant´s Safety in an Electronic and Magnetic Field Environment
|
||
Withdrawn |
NCT01359683 -
Heart Rate Variability Changes During Cardiac Surgery And The Incidence Of Post-Operative Cardiac Arrhythmias
|
N/A | |
Recruiting |
NCT04154982 -
N-Acetylcysteine Protection Against Radiation Induced Cellular Damage
|
Phase 2 | |
Completed |
NCT04609683 -
Measuring Hydration Levels of Healthy and Heart Failure Patients Before, During, and After an Electrophysiology (EP) Procedure
|
N/A | |
Completed |
NCT04162249 -
High Radiofrequency Power for Faster and Safer Pulmonary Veins Isolation - a Pilot Observational Study.
|
||
Withdrawn |
NCT05084391 -
Phase I/II Randomized Study of Stereotactic Ablative Radiotherapy (SABR) Versus Standard of Care for Refractory Structural Cardiac Arrhythmias (SABR-HEART)
|
Phase 1/Phase 2 | |
Completed |
NCT03260244 -
EnSite Precision Observational Study
|
||
Recruiting |
NCT04474418 -
Psychometric Characterization of Patients With Cardiac Arrhythmias
|
||
Recruiting |
NCT03996954 -
Validation of a Smartphone-based Recorder for Detection of Cardiac Arrhythmias
|
N/A | |
Recruiting |
NCT05508880 -
SIGIL: Signal Interpretation and Analysis In Real Life Cardiac Arrhythmias
|
||
Terminated |
NCT04552665 -
Prospective Procedural Data Collection for Continuous Improvement of the KODEX - EPD™ System Performance.
|
||
Recruiting |
NCT06073509 -
Atrial Fibrillation and Other Cardiac Arrhythmias and Diseases After Radiotherapy for Breast Cancer : Watch Your HeaRT
|
||
Completed |
NCT04463524 -
Screening for Hearth Rhythm Disorders
|
||
Withdrawn |
NCT01394965 -
Electrocardiographic Mapping and Imaging
|
Phase 0 | |
Completed |
NCT01672528 -
Patient Reported Outcome Measures for Ablation of Cardiac Arrhythmias
|
||
Completed |
NCT02232204 -
Sleep and Ventricular Arrhythmias Study
|
Phase 2 | |
Completed |
NCT05114382 -
An Evaluation of the Safety and Performance of the CathVision Cube® System
|
N/A |