Cardiac Arrhythmia Clinical Trial
Official title:
Use of the Rhytmia System for Determining the Precise Location and Potential Mechanism of Premature Ventricular Contractions
This is a purely observational project and the objectives are to record and analyze the local potentials at the site of Premature Ventricular Contraction (VPC) focus through the Rhythmia system, ti determine the short and long-term success of the procedure and compare it to the existing literature about standard procedures, to highlight the advantages of the system compared to conventional mapping and to characterize optimal pace map or activation map as achieved by the Rhythmia system.
This is a purely observational study. No special methodology choice, no comparison.
The study want to find the determination of precise location of the focus and mechanisms
involved constitutes a challenge for conventional electrophysiology, even with tridimensional
systems, because of the time needed for accurate delineation of the location (due to the
sometimes unfrequent Ventricular Premature Beats (VPB)) and to the insufficient mapping
density or inadequate signal characteristics. The Rhythmia system could allow better
determination of the focus location in relation to the anatomical structures, especially with
unfrequent VPB, because of the available high density mapping due to the number of closed
high-resolution electrodes located on the Orion catheter. Better delineation of the true
focus origin and of the mechanisms involved (automaticity vs re-entry) may be of useful help
for better understanding and efficient therapy.
;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT05067114 -
Solutions for Atrial Fibrillation Edvocacy (SAFE)
|
||
Completed |
NCT02241252 -
Using an iPhone ECG to Monitor the QT Interval on Dofetilide and Sotalol Patients
|
N/A | |
Completed |
NCT01428778 -
Berlin Beat of Running Study
|
N/A | |
Completed |
NCT01626261 -
Examination of Implant´s Safety in an Electronic and Magnetic Field Environment
|
||
Withdrawn |
NCT01359683 -
Heart Rate Variability Changes During Cardiac Surgery And The Incidence Of Post-Operative Cardiac Arrhythmias
|
N/A | |
Recruiting |
NCT04154982 -
N-Acetylcysteine Protection Against Radiation Induced Cellular Damage
|
Phase 2 | |
Completed |
NCT04609683 -
Measuring Hydration Levels of Healthy and Heart Failure Patients Before, During, and After an Electrophysiology (EP) Procedure
|
N/A | |
Completed |
NCT04162249 -
High Radiofrequency Power for Faster and Safer Pulmonary Veins Isolation - a Pilot Observational Study.
|
||
Withdrawn |
NCT05084391 -
Phase I/II Randomized Study of Stereotactic Ablative Radiotherapy (SABR) Versus Standard of Care for Refractory Structural Cardiac Arrhythmias (SABR-HEART)
|
Phase 1/Phase 2 | |
Completed |
NCT03260244 -
EnSite Precision Observational Study
|
||
Recruiting |
NCT04474418 -
Psychometric Characterization of Patients With Cardiac Arrhythmias
|
||
Recruiting |
NCT03996954 -
Validation of a Smartphone-based Recorder for Detection of Cardiac Arrhythmias
|
N/A | |
Recruiting |
NCT05508880 -
SIGIL: Signal Interpretation and Analysis In Real Life Cardiac Arrhythmias
|
||
Terminated |
NCT04552665 -
Prospective Procedural Data Collection for Continuous Improvement of the KODEX - EPD™ System Performance.
|
||
Recruiting |
NCT06073509 -
Atrial Fibrillation and Other Cardiac Arrhythmias and Diseases After Radiotherapy for Breast Cancer : Watch Your HeaRT
|
||
Completed |
NCT04463524 -
Screening for Hearth Rhythm Disorders
|
||
Withdrawn |
NCT01394965 -
Electrocardiographic Mapping and Imaging
|
Phase 0 | |
Completed |
NCT01672528 -
Patient Reported Outcome Measures for Ablation of Cardiac Arrhythmias
|
||
Completed |
NCT02232204 -
Sleep and Ventricular Arrhythmias Study
|
Phase 2 | |
Completed |
NCT05114382 -
An Evaluation of the Safety and Performance of the CathVision Cube® System
|
N/A |