Cardiac Arrhythmia Clinical Trial
Official title:
Remote Patient Management of Cardiac Implantable Electronic Devices - Tachy
This is a Canadian multicenter randomized controlled trial to assess remote patient management. Patients will be randomized to remote patient management versus usual care, and will be stratified by RemoteView vs no RemoteView utilization, as well as by center.
Remote monitoring (RM) has been in use for over a decade and is now used in a blended system of in clinic visits and RM to provide CIED follow up. Prior studies have focused on this blended model of follow up. In this study, we propose a paradigm shift in CIED follow up care that is fully remote, supported by a patient-centered communication system permitting patients to have greater understanding of their CIED and its function. Patients would not have to leave their own communities to obtain state-of-the art care for their cardiac condition or their CIED. Given the burgeoning use of CIEDs (ICDs and PMs), the aging population and particularly in Canada where 19% of the inhabitants are in communities classified as 'rural', many have long distances to travel to reach a health care facility, it is of the utmost importance to take full advantage of available and developing technologies to improve CIED follow up beyond current recommendations. During the life of these patients, many issues may arise, such as atrial or ventricular arrhythmias that may result in syncope, stroke or sudden death, need for increased monitoring resulting from device advisories, or minor programming adjustments to improve device performance, or simply the need for enhanced surveillance as the device battery depletes and replacement is anticipated. New technology has become available that not only permits surveillance, but also permits communication back to the patient, and their respective providers regarding the status of these devices. The combination of technologies will result in a total care of CIEDs termed Remote Patient Management - CIED (RPM-CIED). The incorporation of enhanced monitoring capability, along with automatic recalibration of device settings, allows us to develop a new paradigm of remote patient management where after the patient receives their device, they would remain in the care of their local health team ('spokes') and no longer require travel to the specialized device clinics ('hubs') for follow-up. It creates capacity in the specialized centers to focus exclusively on the problematic cases by removing the need for routine checks. There are two avenues of new technology that will be used in this study: 1. Remote View: this secure, web-based portal facilitates a virtual view of the device programming by the specialist in real-time while the patient is in their local clinic, thus avoiding patient travel to the specialized clinic (hub). 2. VIRTUES (Virtual Integrated Reliable Transformative User-driven E-health System): this portal has been developed by the Cardiac Arrhythmia Network of Canada to allow the patient to receive reports from the remote transmissions of their device. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT05067114 -
Solutions for Atrial Fibrillation Edvocacy (SAFE)
|
||
Completed |
NCT02241252 -
Using an iPhone ECG to Monitor the QT Interval on Dofetilide and Sotalol Patients
|
N/A | |
Completed |
NCT01428778 -
Berlin Beat of Running Study
|
N/A | |
Completed |
NCT01626261 -
Examination of Implant´s Safety in an Electronic and Magnetic Field Environment
|
||
Withdrawn |
NCT01359683 -
Heart Rate Variability Changes During Cardiac Surgery And The Incidence Of Post-Operative Cardiac Arrhythmias
|
N/A | |
Recruiting |
NCT04154982 -
N-Acetylcysteine Protection Against Radiation Induced Cellular Damage
|
Phase 2 | |
Completed |
NCT04609683 -
Measuring Hydration Levels of Healthy and Heart Failure Patients Before, During, and After an Electrophysiology (EP) Procedure
|
N/A | |
Completed |
NCT04162249 -
High Radiofrequency Power for Faster and Safer Pulmonary Veins Isolation - a Pilot Observational Study.
|
||
Withdrawn |
NCT05084391 -
Phase I/II Randomized Study of Stereotactic Ablative Radiotherapy (SABR) Versus Standard of Care for Refractory Structural Cardiac Arrhythmias (SABR-HEART)
|
Phase 1/Phase 2 | |
Completed |
NCT03260244 -
EnSite Precision Observational Study
|
||
Recruiting |
NCT04474418 -
Psychometric Characterization of Patients With Cardiac Arrhythmias
|
||
Recruiting |
NCT03996954 -
Validation of a Smartphone-based Recorder for Detection of Cardiac Arrhythmias
|
N/A | |
Recruiting |
NCT05508880 -
SIGIL: Signal Interpretation and Analysis In Real Life Cardiac Arrhythmias
|
||
Terminated |
NCT04552665 -
Prospective Procedural Data Collection for Continuous Improvement of the KODEX - EPD™ System Performance.
|
||
Recruiting |
NCT06073509 -
Atrial Fibrillation and Other Cardiac Arrhythmias and Diseases After Radiotherapy for Breast Cancer : Watch Your HeaRT
|
||
Completed |
NCT04463524 -
Screening for Hearth Rhythm Disorders
|
||
Withdrawn |
NCT01394965 -
Electrocardiographic Mapping and Imaging
|
Phase 0 | |
Completed |
NCT01672528 -
Patient Reported Outcome Measures for Ablation of Cardiac Arrhythmias
|
||
Completed |
NCT02232204 -
Sleep and Ventricular Arrhythmias Study
|
Phase 2 | |
Completed |
NCT05114382 -
An Evaluation of the Safety and Performance of the CathVision Cube® System
|
N/A |