Clinical Trials Logo

Clinical Trial Summary

Our ultimate goal is to design a multi-center randomized trial to test the hypothesis that targeted testing for transthyretin cardiac amyloid (ATTR) will improve survival and health status among aortic stenosis patients who undergo transcatheter aortic valve replacement (TAVR). The hypothesis of this pilot study is to evaluate if invasive cardiac hemodynamics obtained after TAVR, by using the AortoVentricular index (AVi), can be used as a novel test to help identify participants with ATTR. Aim 1. To determine if an abnormal AVi value can identify ATTR among aortic stenosis patients undergoing TAVR. Aim 2. To determine if s' from echocardiography plus AVi can enhance the prediction of ATTR among aortic stenosis patients undergoing TAVR. Aim 3. To design a pilot trial to improve patient outcomes after TAVR by targeted testing for ATTR.


Clinical Trial Description

Aim 1. To determine if an abnormal AVi value can identify ATTR among aortic stenosis patients undergoing TAVR. Patients undergoing TAVR for symptomatic severe aortic stenosis, with pre-TAVR echocardiography and post-implantation invasive hemodynamic assessment are eligible for study participation. The AVi will be recorded from post-implantation invasive hemodynamic assessment. Participants will undergo bone scintigraphy (99mTc-pyrophosphate Planar/SPECT imaging) within 28 days after TAVR. Participants with abnormal bone scintigraphy require evaluation for a monoclonal protein with blood/urine laboratory testing, and possible tissue biopsy/Hematology consultation to exclude light-chain amyloidosis. Participants who are ATTR positive will receive comprehensive heart failure management and possible genetic testing to evaluate for mutated ATTR. The prevalence of ATTR will be reported among participants with AVi <0.5 versus ≥0.5 mm Hg/beats per minute. Test performance of AVi to predict ATTR will be reported. Aim 2. To determine if s' obtained from echocardiography tissue Doppler imaging plus AVi can enhance the prediction of ATTR among aortic stenosis patients undergoing TAVR. The s' will be recorded from pre-TAVR tissue Doppler imaging of the mitral annulus. The prevalence of ATTR will be reported among participants with both s' ≤6 cm/second and AVi <0.5 mm Hg/beats per minute versus s' >6 cm/second and AVi <0.5 mm Hg/beats per minute. Aim 3. To design a pilot trial to improve patient outcomes after TAVR by targeted testing for ATTR. The change in Kansas City Cardiomyopathy Questionnaire-12 from baseline to 12-months and survival with reasonable quality of life at 12-months will be reported among participants who are ATTR positive vs. ATTR negative. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04363294
Study type Interventional
Source University of Texas Southwestern Medical Center
Contact
Status Withdrawn
Phase N/A
Start date March 2022
Completion date August 2023

See also
  Status Clinical Trial Phase
Completed NCT03186339 - Validation of the "TASQ" in Patients Undergoing SAVR or TF-TAVI
Recruiting NCT03549559 - Imaging Histone Deacetylase in the Heart N/A
Terminated NCT02854319 - REpositionable Percutaneous Replacement of NatIve StEnotic Aortic Valve Through Implantation of LOTUS EDGE Valve System N/A
Recruiting NCT05601453 - The ReTAVI Prospective Observational Registry
Withdrawn NCT05481814 - CPX in Paradoxical Low Flow Aortic Stenosis
Completed NCT02241109 - Predicting Aortic Stenosis Progression by Measuring Serum Calcification Propensity N/A
Completed NCT01700439 - Surgical Treatment of Aortic Stenosis With a Next Generation, Rapid Deployment Surgical Aortic Valve N/A
Recruiting NCT04429035 - SLOW-Slower Progress of caLcificatiOn With Vitamin K2 N/A
Completed NCT04103931 - Impact of a Patient Decision Aid for Treatment of Aortic Stenosis N/A
Completed NCT03950440 - Assessing the Incidence of Postoperative Delirium Following Aortic Valve Replacement
Active, not recruiting NCT02661451 - Transcatheter Aortic Valve Replacement to UNload the Left Ventricle in Patients With ADvanced Heart Failure (TAVR UNLOAD) N/A
Completed NCT02792452 - Clinical Value of Stress Echocardiography in Moderate Aortic Stenosis
Completed NCT02758964 - Evaluation of Cerebral Thrombembolism After TAVR
Completed NCT02847546 - Evaluation of the BARD® True™ Flow Valvuloplasty Perfusion Catheter for Aortic Valve Dilatation N/A
Not yet recruiting NCT02536703 - Safety and Efficacy of Lotus Valve For TAVI In Patients With Severe Aortic Stenosis In Chinese Population Phase 3
Not yet recruiting NCT02541877 - Sizing-sTrategy of Bicuspid AoRtic Valve Stenosis With Transcatheter Self-expandable Valve Phase 3
Completed NCT02249000 - BIOVALVE - I / II Clincial Investigation N/A
Not yet recruiting NCT02221921 - Safety and Efficacy Study of MicroPort's Transcatheter Aortic Valve and Delivery System for TAVI N/A
Active, not recruiting NCT02080299 - Protection by Remote Ischemic Preconditioning During Transcatheter Aortic Valve Implantation Phase 2
Terminated NCT01939678 - Characterization and Role of Mutations in Sodium-phosphate Cotransporters in Patients With Calcific Aortic Valve Disease