Clinical Trials Logo

Clinical Trial Summary

This is a prospective, single arm, open, single centre clinical investigation designed to examine the feasibility and safety of the IscAlertâ„¢ device in patients scheduled for limb (arm/leg) surgery with tourniquet. IscAlert is measuring carbon dioxide in muscular and subcutaneous tissue. IscAlert is inserted into normal muscle and subcutaneous tissue in ischemic (operated limb with a tourniquet) and non-ischemic limb (non-operated limb).After the tourniquet is inflated, ischemia develops in the muscles and subcutaneous tissue. This will result in an increase in carbon dioxide, which will be detected by the sensor on the operated extremity, while the sensor on the non-operated will show normal values. After releasing the tourniquet cuff, the muscle will be reperfused and the carbon dioxide level is expected to decrease into normal levels. 50 number of patients will be enrolled to undergo the procedures. The IscAlert will be removed from the patient before the patient is discharged from the operating room, but in 25 of the patients, IscAlertâ„¢ will be inserted for 72 hours in the operated extremity after the end of surgery. After this, the sensors are removed.250 Devices is planned to be used in this clinical study.


Clinical Trial Description

This is a prospective, single arm, open, single centre clinical investigation designed to examine the feasibility and safety of the IscAlertâ„¢ device in patients scheduled for limb (arm/leg) surgery with tourniquet. 50 number of patients will be enrolled to undergo the procedures detailed in this clinical investigational plan using 250 devices. IscAlert is 0.8 mm in diameter and in vitro testing, shows stable and accurate measurements of tissue carbon dioxide . More than 100 animal experiments have been done with the sensor. The experiments have shown that the sensor detects ischemia (Increased carbon dioxide-measurements) in real time in the following organs and tissues: Brain, heart, liver, kidneys, pancreas, intestines, musculature and subcutaneous tissue. Sensitivity and specificity are close to 100%. The sensors are inserted into tissue by a split needle technique. The split needle is the size of a 3-gauge peripheral venous catheter. In animal studies, no complications have been detected when using the sensor. The IscAlert catheters are connected to an electronics unit that is fixed to the skin with an adhesive plaster outside the sterile area. The electrical signals are redirected to a personal computer approved for clinical use which continuously records tissue pressures of carbon dioxide . IscAlert is inserted into normal muscle and subcutaneous tissue proximal on the limb to be operated. The insertion is distal to the blood cuff, and far away from the surgery field. The insertion is done under sterile conditions in accordance with standard sterility criteria at the hospital. No pain during insertion will occur because of insertion is performed after anesthesia induction. Also, the insertion can be compared to an intramuscular injection. An identical IscAlert catheter is also inserted in the opposite extremity that is not to be operated and serves as a reference value. After the tourniquet is inflated, ischemia develops in the muscles and subcutaneous tissue. This will result in an increase in carbon dioxide, which will be detected by the sensor on the operated extremity, while the sensor on the non-operated will show normal values. After releasing the tourniquet cuff, the muscle will be reperfused and the carbon dioxide level is expected to decrease into normal levels within 15 - 45 minutes. In 25 patients, the biosensors will be removed from the patient before the patient is discharged from the operating room, but in 25 of the patients, IscAlert will be inserted for 72 hours in the operated extremity after the end of surgery to identify drifting of the sensors. After this, the sensors are removed. The primary objective is to evaluate the ability of the IscAlert device to measure carbon dioxide levels in ischemic and non-ischemic limb musculature and subcutaneous tissue in patients who experience orthopedic surgery with limb tourniquet and to assess the safety/efficacy using device IscAlert. Our hypotheses are: 1. The IscAlert device will be able to detect the presence of ischemia in muscle and subcutaneous tissue, whereby carbon dioxide levels, measured by IscAlert, will be higher in ischemic musculature than non-ischemic musculature in patients undergoing orthopedic limb surgery. 2. No clinically significant bleeding or infection will occur using IscAlert in this clinical study. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04893473
Study type Observational
Source Oslo University Hospital
Contact
Status Withdrawn
Phase
Start date May 14, 2021
Completion date May 14, 2021

See also
  Status Clinical Trial Phase
Recruiting NCT05443061 - Subcutaneous Nitroglycerin to Prevent Radial Artery Occlusion in Children N/A
Recruiting NCT05158257 - Clinical Of Plain Balloon Dilatation Combined Stent Versus Endovascular Debulking Combined Drug-coated Balloon to Treat Arteriosclerosis Occlusive Disease of Lower Extremity N/A
Recruiting NCT06006975 - Early Warning of Delayed Cerebral Ischemia
Active, not recruiting NCT02758847 - Evaluation of Paclitaxel in Patients With CLI and Femoropopliteal Occlusive Disease Treated With DCB Angioplasty N/A
Not yet recruiting NCT02871622 - BMX Alpha Registry: a Post-market Registry of the BioMatrix Alpha TM N/A
Completed NCT02557282 - CARESTREAM Vue PACS v12.1.5 CT Perfusion Clinical Protocol
Enrolling by invitation NCT02033681 - Optimal Time Delay of Epinephrine Injection With "One-per-mil" Tumescent Solution N/A
Completed NCT01608035 - Sciatic Perineural Versus Stump Catheter for Below Knee Amputation Phase 0
Active, not recruiting NCT01518842 - Effect of Intravitreal Bone Marrow Stem Cells on Ischemic Retinopathy N/A
Completed NCT01625832 - Effects of Coronary Sinus Occlusion on Myocardial Ischemia (Pilot Study) N/A
Active, not recruiting NCT01281241 - Study on Mechanical and Electrical Alternans N/A
Completed NCT00778323 - Clinical Trial of Remote Preconditioning in Patients Undergoing Cervical Decompression Surgery Phase 1/Phase 2
Completed NCT00371371 - Intra-arterial Stem Cell Therapy for Patients With Chronic Limb Ischemia (CLI) Phase 1/Phase 2
Terminated NCT00760708 - Circulating Adenosine Levels Before and After Intravenous (IV) Persantine
Not yet recruiting NCT06039748 - Angiography-Derived Quantitative Functional Assessment Versus Pressure-Derived FFR and IMR: The FAIR Study
Completed NCT04879875 - New Method for Real-time Detection of Tissue Ischemia (ISCALERT) N/A
Completed NCT00526474 - Trial to Assess the Effects of Vorapaxar (SCH 530348; MK-5348) in Preventing Heart Attack and Stroke in Patients With Atherosclerosis (TRA 2°P - TIMI 50) (P04737) Phase 3
Completed NCT03994822 - pRESET for Occlusive Stroke Treatment N/A
Completed NCT02910778 - The Effect of Ticagrelor With or Without Atorvastatin on Endothelial Function in Healthy Males Phase 4
Completed NCT02552498 - Post Occlusive Reactive Hyperemia on Gingiva Assessed by Laser Speckle Contrast Imaging N/A