Burns Clinical Trial
Official title:
Effect of Antigravity Treadmill (Alter G) Training on Gait Characteristics and Balance After Healed Adult Burns: A Randomized Controlled Trial
Severe burn injuries are associated with hypermetabolic responses and increased catabolism. These generalized changes lead to a vast loss of muscle mass and cause reduced muscle strength and endurance, limited walking ability, and reduced functional mobility Recently, the antigravity treadmill or lower body positive pressure (LBPP) technology has been developed as a unique system of maintaining a participant's body weight all through treadmill training and developing low-load treadmill walking using a unique treadmill system that allows gaining the benefits of low-load treadmill walking without interrupting with locomotion dynamics
Objective: This single-blind randomized controlled trial aimed to examine the effects of antigravity treadmill training on gait characteristics and balance in healed adult burned patients. Methods: Fifty-five adult burn patients were chosen to participate in this study, their ages ranged from 18 to 35 years. They were randomly allocated to Alter G (ALG) (n=22), and control (Cont) (n=23) groups. The control group received a traditional physical therapy program (TPTP), three times per week. In contrast, the experimental group received antigravity treadmill training (30 minutes,3 times/week, speed 0.1 m/sec, 75% body weight) in addition to the traditional physical therapy program given to the control group. All study participants followed the instructions recommended for the exercise performed (three days per week) in terms of intensity, type, and duration to limit any difference between groups, as well as instructions about not exercising the rest of the week. During the study period, both groups received standard medical care. outcome measures: gait characteristics and postural stability indices were measured at the baseline (pre) and end of 12 weeks of intervention (post). The Statistical Package for the Social Sciences (SPSS) software was used for statistical analysis. The Shapiro-Wilk test was used to determine the normality of the data. The paired t-test was used to test within-group comparisons of mean changes in muscle strength, gait characteristics, and postural stability indices. The unpaired t-test was used to compare between groups. P<0.05 was chosen as the level of significance. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT05023135 -
DeepView SnapShot Portable (DV-SSP): Device Training Study
|
||
Completed |
NCT05276869 -
Reliability and Feasibility of WeeFIM Instrument to Measure Functional Independence in Pediatric Burns
|
||
Completed |
NCT04548635 -
VR for Burn Dressing Changes at Home
|
Phase 2/Phase 3 | |
Not yet recruiting |
NCT06076031 -
Effects of Applying Streaming Media on Reducing Pain in Patient With Second-degree Burn During Changing Dressing
|
N/A | |
Recruiting |
NCT05084248 -
Vitamin D Deficiency in Adults Following a Major Burn Injury
|
Phase 4 | |
Completed |
NCT03113253 -
TRANexamic Acid to Reduce Bleeding in BURN Surgery
|
Phase 4 | |
Recruiting |
NCT04090424 -
Assessment of Safety and Effectiveness of NovoSorb® BTM in Severe Burns
|
N/A | |
Not yet recruiting |
NCT05649891 -
Checklists Resuscitation Emergency Department
|
N/A | |
Withdrawn |
NCT03159182 -
Study of Silicone Material Inserts To Treat Burn Scars
|
N/A | |
Recruiting |
NCT02904941 -
Human Amniotic Versus Synthetic Membrane as a Transient Skin Cover for Pediatric Burns
|
N/A | |
Completed |
NCT02681757 -
Comparison of Mepitel Ag vs Antibiotic Ointment Used With Soft Cast Technique for Treatment of Pediatric Burns
|
N/A | |
Recruiting |
NCT01812941 -
Evaluation of Mitochondrial Dysfunction in Severe Burn and Trauma Patients
|
N/A | |
Completed |
NCT01437852 -
StrataGraft® Skin Tissue as an Alternative to Autografting Deep Partial-Thickness Burns
|
Phase 1 | |
Completed |
NCT01214811 -
Open Multi-centre Investigation to Evaluate Signs and Symptoms of Local Inflammation/Infection on Chronic Ulcers and Partial Thickness Burns When Using Mepilex Border Ag as an Anti-microbial Wound Dressing
|
Phase 3 | |
Completed |
NCT01061502 -
Efficacy Study of a Bioelectric Dressing to Treat Skin Graft Donor Site Wounds
|
Phase 1/Phase 2 | |
Terminated |
NCT00822796 -
Thermogard™ Efficacy Trial
|
N/A | |
Terminated |
NCT00824681 -
Effect of Music Therapy on Families of Burn Patients
|
Phase 1 | |
Terminated |
NCT00634166 -
Effects of Therapy With Sulfamylon® 5% Topical Solution Compared to a Historical Control Group
|
Phase 4 | |
Terminated |
NCT00464386 -
Continuous Glucose Monitoring (POC) in the ICU
|
N/A | |
Withdrawn |
NCT00216983 -
Proline Metabolism in Severely Burned Patients: Effect of Modulated Parenteral Feeding
|
N/A |