Clinical Trials Logo

Clinical Trial Summary

The investigators developed a portable pressure measuring device using silicon piezoresistive pressure sensors. As PicoPress® is the most accurate (i.e., lowest variation and error) manometric sensor for pressure measurement, the investigators used it to compare and examine the accuracy of the proposed device regarding in vitro pressure measurements. The purpose of this study was to determine the effectiveness of pressure garment therapy using proposed device with objective data obtained with a randomized within wound comparison. Pressure measurements were acquired through a readout circuit consisting of an analog-to-digital converter, a microprocessor, and a Bluetooth transmission module for wireless data transmission to an external device. The mean pressure values measured by the sensors were compared to those obtained from PicoPress®. This was a double-blinded, randomized, controlled trial of patients with hypertrophic scars. In the pressure monitoring group, garment pressures were monitored using the portable pressure measuring device, and the compression garment was adjusted so that the pressure was maintained at the therapeutic range of 15 - 25 mmHg. In the control group, non-surgical standard treatment of burn scars except for pressure monitoring was performed in the same manner.


Clinical Trial Description

The investigators developed a portable pressure measuring device using silicon piezoresistive pressure sensors. As PicoPress® is the most accurate (i.e., lowest variation and error) manometric sensor for pressure measurement, the investigators used it to compare and examine the accuracy of the proposed device regarding in vitro pressure measurements. The purpose of this study was to determine the effectiveness of pressure garment therapy using proposed device with objective data obtained with a randomized within wound comparison. Pressure measurements were acquired through a readout circuit consisting of an analog-to-digital converter, a microprocessor, and a Bluetooth transmission module for wireless data transmission to an external device. The mean pressure values measured by the sensors were compared to those obtained from PicoPress®. This was a double-blinded, randomized, controlled trial of patients with hypertrophic scars. In the pressure monitoring group, garment pressures were monitored using the portable pressure measuring device, and the compression garment was adjusted so that the pressure was maintained at the therapeutic range of 15 - 25 mmHg. In the control group, non-surgical standard treatment of burn scars except for pressure monitoring was performed in the same manner. To evaluate the effect of a pressure monitoring device, the investigators compared the skin test results (thickness, melanin, erythema, TEWL, and skin elasticity levels) between the two groups, from baseline measures immediately before the treatment and measures immediately after 2 months. The participants were made comfortable and acclimatized to room conditions. Room temperature was maintained at 20-25'C and relative humidity at 40-50 %. In the supine position, skin properties were measured. The thickness was measured with a ultrasonic wave equipment (128 BW1 Medison, Korea). Mexameter® (MX18, Courage-Khazaka Electronics GmbH, Germany) was used to measure melanin levels and the severity of erythema. The higher values indicating a darker and redder skin. Transepidermal water loss (TEWL) was measured with a Tewameter® (Courage-Khazaka Electronic GmbH, Germany), which is used for evaluating water evaporation. Elasticity was measured using Cutometer SEM 580® (Courage-Khazaka Electronic GmbH, Cologne, Germany), which applies negative pressure (450 mbar) on the skin. The numeric values (mm) of the skin's distortion is presented as the elasticity. Two seconds of negative pressure of 450 mbar is followed by 2 s of recess, and this consists of a complete cycle. Three measurement cycles were conducted, and the average values were obtained. The parameters consist of the following biomechanical skin properties: distenstibility, elasticity, and viscoelasticity. Distensibility means the length of total displacement from initial postion at maximum negative pressure. Gross elasticity means the ability of the skin to return to its initial position following displacement. Biologic elasticity means the ratio of immediate retraction to total displacement. Viscoelasticity means the ratio of delayed distension of immediate distension. Outcome measurements and data analyses were performed by a trained and blinded outcome assessor who was not involved in the intervention. Possible complications (pain, ecchymosis, pain, skin abrasion, and swelling) were observed. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04456543
Study type Interventional
Source Hangang Sacred Heart Hospital
Contact
Status Recruiting
Phase N/A
Start date June 10, 2020
Completion date August 20, 2020

See also
  Status Clinical Trial Phase
Completed NCT05023135 - DeepView SnapShot Portable (DV-SSP): Device Training Study
Completed NCT05276869 - Reliability and Feasibility of WeeFIM Instrument to Measure Functional Independence in Pediatric Burns
Completed NCT04548635 - VR for Burn Dressing Changes at Home Phase 2/Phase 3
Not yet recruiting NCT06076031 - Effects of Applying Streaming Media on Reducing Pain in Patient With Second-degree Burn During Changing Dressing N/A
Recruiting NCT05084248 - Vitamin D Deficiency in Adults Following a Major Burn Injury Phase 4
Completed NCT03113253 - TRANexamic Acid to Reduce Bleeding in BURN Surgery Phase 4
Recruiting NCT04090424 - Assessment of Safety and Effectiveness of NovoSorb® BTM in Severe Burns N/A
Not yet recruiting NCT05649891 - Checklists Resuscitation Emergency Department N/A
Withdrawn NCT03159182 - Study of Silicone Material Inserts To Treat Burn Scars N/A
Recruiting NCT02904941 - Human Amniotic Versus Synthetic Membrane as a Transient Skin Cover for Pediatric Burns N/A
Completed NCT02681757 - Comparison of Mepitel Ag vs Antibiotic Ointment Used With Soft Cast Technique for Treatment of Pediatric Burns N/A
Recruiting NCT01812941 - Evaluation of Mitochondrial Dysfunction in Severe Burn and Trauma Patients N/A
Completed NCT01437852 - StrataGraft® Skin Tissue as an Alternative to Autografting Deep Partial-Thickness Burns Phase 1
Completed NCT01214811 - Open Multi-centre Investigation to Evaluate Signs and Symptoms of Local Inflammation/Infection on Chronic Ulcers and Partial Thickness Burns When Using Mepilex Border Ag as an Anti-microbial Wound Dressing Phase 3
Completed NCT01061502 - Efficacy Study of a Bioelectric Dressing to Treat Skin Graft Donor Site Wounds Phase 1/Phase 2
Terminated NCT00822796 - Thermogard™ Efficacy Trial N/A
Terminated NCT00824681 - Effect of Music Therapy on Families of Burn Patients Phase 1
Terminated NCT00634166 - Effects of Therapy With Sulfamylon® 5% Topical Solution Compared to a Historical Control Group Phase 4
Terminated NCT00464386 - Continuous Glucose Monitoring (POC) in the ICU N/A
Withdrawn NCT00216983 - Proline Metabolism in Severely Burned Patients: Effect of Modulated Parenteral Feeding N/A