Bradyarrhythmia Clinical Trial
— MASS2Verified date | November 2018 |
Source | Medtronic Cardiac Rhythm and Heart Failure |
Contact | n/a |
Is FDA regulated | No |
Health authority | |
Study type | Interventional |
The purpose of the MASS2 is to characterize accelerometer signals of Micra implantable device during different postures and activities and to understand the source of the sensed motion, in order to test feasibility for future enhancements in device functionalities.
Status | Completed |
Enrollment | 43 |
Est. completion date | April 25, 2017 |
Est. primary completion date | April 25, 2017 |
Accepts healthy volunteers | No |
Gender | All |
Age group | 18 Years and older |
Eligibility |
Inclusion Criteria: - Subject is = 18 years old - Subject is implanted with a Micra device - Subject or witness (if applicable as per local regulation) is able and willing to provide Informed Consent Exclusion Criteria: - Subject is in atrial fibrillation - Subject is not able to perform study requirements |
Country | Name | City | State |
---|---|---|---|
Austria | Kepler Universitätsklinikum | Linz | |
France | Hôpital cardiologique du Haut-Lévêque | Pessac | |
France | CHRU Tours - Hopital Trousseau | Tours | |
Spain | Hospital Clinic | Barcelona |
Lead Sponsor | Collaborator |
---|---|
Medtronic Cardiac Rhythm and Heart Failure |
Austria, France, Spain,
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Waveform and Components of Accelerometer Signal | Accelerometer signal was measured using the 3 axis Micra accelerometer (Vector 1 was labelled as V1, Vector 2 as V2, Vector 3 as V3). Components of the accelerometer signals (unit (g) represent acceleration)were identified and labelled as A1 (acceleration associated with ventricular systole), A2 (ventricular diastole), A3 (early passive filling), and A4 (active filling). The A4 signal is associated with atrial contraction and active filling. |
For approximately two hours after software download |
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT00976482 -
Clinical Outcome of Pacemaker paTIents According to Pacing Modality and Primary INDications
|
N/A | |
Completed |
NCT01089634 -
Left Ventricular Capture Management Study
|
||
Recruiting |
NCT03693157 -
The Safety and Efficacy of FFR Protocol in NTUH System
|
||
Completed |
NCT05357716 -
Preliminary Research Evaluation for Ambulatory Leadless Electrocardiogram Recorder Trial
|
||
Recruiting |
NCT05585411 -
PReventive Effect Of Left Bundle Branch Area Pacing Versus righT vEntricular paCing on All Cause deaTh, Heart Failure Progression, and Ventricular dysSYNChrony in Patients With Substantial Ventricular Pacing (PROTECT-SYNC): Multicenter Prospective Randomized Controlled Trial
|
N/A | |
Completed |
NCT01522755 -
Predictive Factors of a Successful Implant of the CapsureFix MRI Model 5086
|
||
Completed |
NCT01513538 -
Analysis of the Acceptance and Changes to Parameters Programming Suggested by the TherapyGuide Function
|
N/A | |
Completed |
NCT05997004 -
Glycopyrrolate Prophylaxis for Prevention of Bradyarrhythmia During Laparoscopic Cholecystectomy
|
N/A | |
Recruiting |
NCT04905199 -
Temporary Transvenous Pacemaker Placement by Intracavitary Electrocardiogram Monitoring
|
||
Recruiting |
NCT05401851 -
Bi-ventricular Epicardial Activation in Left Bundle Area Pacing: a Comparison Study
|
N/A | |
Not yet recruiting |
NCT04437901 -
COVIDAR - Arrhythmias in COVID-19
|
||
Completed |
NCT01523704 -
Safety and Efficacy Study of IPG Patient With Home Monitoring
|
N/A | |
Terminated |
NCT01535404 -
Right Versus Left Apical Transvenous Pacing for Patients With Preserved Left Ventricular Systolic Function Study
|
N/A | |
Recruiting |
NCT06324682 -
ConTempoRary Cardiac Stimulation in Clinical practicE: lEft, BivEntriculAr, Right, and conDuction System Pacing
|
||
Completed |
NCT01715558 -
Clinical Outcome of Pacemaker paTIents According to Pacing Modality and Primary INDications OPTI-MIND 2
|
N/A | |
Recruiting |
NCT01310907 -
Identify the Genes Polymorphisms Related to Non-familial Bradyarrhythmia
|
N/A | |
Recruiting |
NCT04697797 -
Mechanical and Electrical Dyssynchrony During His-Bundle Pacing Versus His-Bundle Area Right Ventricular Pacing
|
||
Recruiting |
NCT04831125 -
Conduction System Pacing International Registry (CONSPIRE)
|
||
Completed |
NCT01897558 -
Myocardial Micro-damage in Relation to Active and Passive Fixation Pacemaker Electrodes
|
N/A |