Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT04510753
Other study ID # CLN-30-0054
Secondary ID
Status Completed
Phase
First received
Last updated
Start date November 22, 2019
Est. completion date December 9, 2020

Study information

Verified date August 2020
Source Sensifree Ltd.
Contact n/a
Is FDA regulated No
Health authority
Study type Observational

Clinical Trial Summary

Collect continuous systolic and diastolic blood pressure values and waveforms as recorded by an arterial line catheter and by non-invasive blood pressure (NIBP) and to collect Photoplethysmogram Pulse Oximetry (PPG) waveform in order to optimize the Sensifree algorithm.


Description:

Sensifree is developing a continuous non-invasive blood pressure measurement system, that uses a fingertip PPG sensor as a signal source. The system provides systolic, diastolic and mean arterial pressure values, for use in hospitals and other clinical settings. The PPG waveform is analyzed by a proprietary software algorithm, calculating BP values. The current best method to obtain similar information is by using an Arterial line catheter which will serve as a reference device. In this study, the sponsor aims to prospectively collect continuous radial arterial line & PPG waveforms, as well as NIBP data over the period of the surgery in order to test and refine the algorithm.


Recruitment information / eligibility

Status Completed
Enrollment 100
Est. completion date December 9, 2020
Est. primary completion date December 9, 2020
Accepts healthy volunteers No
Gender All
Age group 18 Years to 80 Years
Eligibility Inclusion Criteria: 1. Signed inform consent 2. Age 18 or greater 3. Elective surgery that requires invasive BP monitoring (A-line) Exclusion Criteria: 1. Emergency surgery 2. A-line not inserted 3. Informed consent not signed

Study Design


Related Conditions & MeSH terms


Intervention

Device:
Arterial catheterization kit
Invasive monitoring of blood pressure via catheterization of the radial artery, displaying a continuous pressure waveform and blood pressure values.
GE Datex-Ohmeda Finger Clip Pulse Oximeter Sensor
PPG fingertip mounted sensor, that measures the oxygen level (oxygen saturation) of the blood and generates a waveform
NIBP Cuff (GE Healthcare)
A blood pressure cuff is used to measure blood pressure. The cuff has an inflatable rubber bladder that is typically fastened around the arm. A pressure meter indicates the cuff's pressure.

Locations

Country Name City State
United States San Francisco Veterans Affairs Medical Center San Francisco California

Sponsors (1)

Lead Sponsor Collaborator
Sensifree Ltd.

Country where clinical trial is conducted

United States, 

Outcome

Type Measure Description Time frame Safety issue
Primary Comparison of BP values between a PPG sensor based device and an arterial line PPG signal will be acquired from the PPG sensor, while blood pressure values (systolic, diastolic, mean) will be acquired from A-line. PPG signal will be analyzed by the Sensifree's algorithm and compared to the A-line BP measurement results according to ISO 81060-2 accuracy specifications The length of each procedure, typically up to 8 hours
See also
  Status Clinical Trial Phase
Completed NCT04100668 - Evaluation of Sensifree's Alpha Sensor Signal Morphology Compared to Arterial Line and PPG Signal Morphologies N/A
Completed NCT04976452 - Identifying Learning Strategies to Improve Blood Pressure Measurement in Physical Therapy Education Programs N/A
Completed NCT02447471 - Agreement of the Nexfin™ Monitor With Non-invasive Blood Pressure Measurement N/A
Not yet recruiting NCT06198855 - Automated Measurement of Blood Pressure in Waiting Room (AMBP-waiting)
Completed NCT04132453 - Continuous Blood Pressure and Waveform Measurements Comparison Between Invasive Arterial Line and PPG Sensor
Completed NCT04456179 - Continuous Non-Invasive Blood Pressure System Data Collection in Comparison to Invasive Radial Arterial Pressure N/A