Clinical Trial Details
— Status: Completed
Administrative data
NCT number |
NCT05273593 |
Other study ID # |
NL71360.018.19 |
Secondary ID |
|
Status |
Completed |
Phase |
N/A
|
First received |
|
Last updated |
|
Start date |
January 6, 2020 |
Est. completion date |
November 12, 2021 |
Study information
Verified date |
March 2022 |
Source |
Academisch Medisch Centrum - Universiteit van Amsterdam (AMC-UvA) |
Contact |
n/a |
Is FDA regulated |
No |
Health authority |
|
Study type |
Interventional
|
Clinical Trial Summary
A prospective monocenter diagnostic accuracy study of Confocal Laser Endomicroscopy (CLE) for
Bladder Cancer(BC) to assess two primary objectives:
1. The diagnostic accuracy of flexible probe-based confocal laser endomicroscopy (CLE)
compared to histopathology of the resection specimen.
2. The diagnostic accuracy of CLE-based assessment of the surgical radicality of the
resection bed (radical vs irradical) in comparison with histopathology of a biopsy of
the resection bed.
All patients with a papillary bladder tumor on cystoscopy will be included in this trial.
Description:
Rationale:
Initial evaluation of gross hematuria consists of White Light Cystoscopy (WLC). Urine
cytology combined with contrast imaging of the upper urothelial tract is performed when a
bladder tumor is seen. Follow up of non-muscle invasive bladder carcinoma (NMIBC) after
initial treatment consists of similar steps. When a suspected lesion is visualized, a
transurethral resection of the bladder tumor (TURBT) is performed for therapeutic and
diagnostic purposes. TURBT is considered to be the gold standard for diagnosis of urothelial
carcinoma of the bladder (UCB). High recurrence rates of UCB after TURBT are reported,
leading to repetitive surgery and high costs. In certain cases of high grade UCB a second
look TURBT has proven to be beneficial after primary resection to ensure radical resection.
Furthermore, recent research suggests that active surveillance for low-grade bladder tumors
is safe. Confocal laser endomicroscopy (CLE), a high resolution optical imaging technique
that can be used in combination with endo-urological procedures, seems promising to improve
diagnosis of urothelial cancer, possibly without the need for immediate transurethral
resection to obtain histological confirmation. CLE characteristics of UCB have been
determined and validated using rigid probes, which are incompatible with flexible cystoscopes
used for outpatient cystoscopies. With the present study, we aim to assess the diagnostic
value of flexible probe based CLE for diagnosis and grading of UCB. Furthermore to possibly
prevent second look TURBT in the future,an assessment of CLE features of the resection bed
using a rigid CLE-probe will be performed.
Objective:
Primary objectives:
This study is two-fold and, therefore, has two primary objectives:
1. Investigating the diagnostic accuracy of CLE (Cystoflex™F probe) during flexible
cystoscopy for diagnosis and grading of urothelial carcinoma of the bladder.
2. To investigate the diagnostic potential of CLE (Cystoflex™ UHD-R probe) for the
assessment of the surgical radicality after transurethral resection of a bladder tumor
(after TURBT)
Secondary objective:
- To construct a convolutional neural network for computer aided assessment of CLE images for
diagnosis and grading of UCB.
Study design:
This is a prospective monocenter, observational diagnostic accuracy study. Diagnostic
accuracy study to compare the CLE-based diagnosis with the histopathologic findings.
Study population: All patients >18 years old with a papillary bladder tumor who are planned
for TURBT are eligible for this study. We will include 60 patients in this pilot study.
Intervention: At the operation theatre, before performing a TURBT for the standard clinical
care, we introduce a flexible cystoscope to map the bladder, then we record CLE images of the
index lesion using the Cystoflex™F. Subsequently, we replace the flexible scope by the
(rigid) resectoscope. We acquire additional images with the Cystoflex™ UHD-R rigid probe. We
perform the TURBT. After completion of the TURBT, we introduce the Cystoflex™ UHD-R probe
again for imaging of the resection bed. At a later stage correlation with a standard biopsy
of the resection bed will be performed.
For CLE imaging, a fluorescent contrast agent (fluorescein) will be used intravesically and
intravenously, respectively, to temporarily stain the extracellular matrix of the urothelium.
We will introduce fluorescein for intravesical use through a bladder catheter and rinse the
fluorescein out of the bladder after an indwelling time of 5-10 minutes. Before CLE
measurement of the resection bed we will administer fluorescein intravenously.
Main study parameters/endpoints:
1. Overall accuracy, sensitivity and specificity of flexible probe CLE-based diagnosis
(benign vs malignant) and grading (low-grade versus high-grade) in comparison with the
histopathology of the resection specimen.
2. Overall accuracy, sensitivity and specificity of CLE-based assessment of the surgical
radicality of the resection bed (radical versus irradical) in comparison with the
histopathology of the biopsy of the resection bed.
Nature and extent of the burden and risks associated with participation, benefit and group
relatedness: Participants will not benefit directly from this study. We hypothesize, however,
that the results of this study will contribute to improvements in the diagnostic and surgical
procedure for UCB. Outpatient-based cystoscopy with the potential diagnostic certainty of
CLE-based grade assessment may enable active surveillance in low-risk UCB, and thus may even
lead to a reduction in surgical procedures. We will introduce a CLE probe before TURBT via
the working channel of the flexible cystoscope and hold it in direct contact with the bladder
tumor to obtain CLE images. Before image acquisition of the bladder tumor we administer
fluorescein intravesical, which is a fluorescent dye, used regularly intravenously in
ophthalmatology. Before image acquisition of the resection bed we administer fluorescein
intravenously. In patients not known with an allergy to this dye, this is a safe procedure.
Patients with a known allergic reaction to fluorescein cannot participate in this study.
Patients will be exposed to approximately 20 minutes of extra surgery time and the
introduction of a flexible cystoscope compared to regular TURBT. As a result there is little
burden to study participation for the patients. Adverse events are not expected based on
previous experiences. The hospital's internal protocol for standard clinical care and
histopathologic evaluation are not going to be affected by the study protocol.