Clinical Trials Logo

Clinical Trial Details — Status: Withdrawn

Administrative data

NCT number NCT03913533
Other study ID # Pro00089994
Secondary ID
Status Withdrawn
Phase N/A
First received
Last updated
Start date December 16, 2019
Est. completion date October 31, 2021

Study information

Verified date September 2021
Source University of Alberta
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

Some newborn babies have difficulty breathing at birth and need help. When babies need help with breathing the clinical team, the team measures heart rate using a stethoscope to check its heart rate and figure out what kind of help they will need. If the heart rate is too low, the clinical team will begin to inflate the baby's lung. Knowing the baby's heart rate quickly is important but the stethoscope is inaccurate, and might delay start of resuscitation. Using a smartphone app that uses screen tapping with a stethoscope could allow heart rate to be measured much faster compared to the stethoscope and allow the clinical team to support the baby's needs better immediately after birth.


Description:

Purpose Nearly 10% of all infants born worldwide require respiratory support at birth and birth asphyxia remains one of the leading causes of infant morbidity and mortality. Neonatal resuscitation is the most effective strategy to deal with this condition. Moreover, an infant's heart rate (HR) is the most significant clinical parameter used to assess the need for and response to neonatal resuscitation. Currently, a newborn's HR is determined by auscultating or palpating of the umbilical cord. Although auscultation is more precise compared to palpation, both methods are inaccurate and tend to underestimate HR. The current resuscitation guidelines also recommend using electrocardiogram (ECG) and pulse oximetry, which allow for continuous monitoring, however are slow to apply and detect HR compared to stethoscopes. During neonatal resuscitation, an infant's HR is necessary to initiate resuscitation and to monitor the effectiveness of each intervention and therefore it becomes essential to accurately and quickly assess an infant's HR during this process. If HR is detected slowly or inaccurately, there is an increased risk that necessary interventions are not started or that certain interventions are prolonged, which could lead to increased morbidity and mortality of the infants. The recent advances in technology, namely the development of a smartphone tap application for HR assessment is promising as a novel tool for quick and accurate HR detection during neonatal resuscitation. Hypothesis The use of a tap-based smartphone application will be faster and more accurate when compared to standard auscultation with the 6-sec method to assess HR. Justification Simulation studies have shown that it is feasible to measure HR using a tap-based application. Moreover, the investigator's group has recently shown its reliability in an animal model of asphyxia-induced neonatal swine. The investigator showed its accuracy compared to the experimental gold standard carotid blood flow-derived HR assessments and report a median time of 3 sec for assessment, which is less than the current recommended time for auscultation. However, no study has been performed in the delivery room in newborn babies at birth. Therefore, the investigator aim to compare the tap-based application to the current 6-sec standard approach to assess HR during neonatal resuscitation in the delivery room. Ehe investigator anticipate this study will allow us to determine the most reliable approach for initial assessment to reduce neonatal morbidity and mortality outcomes. Objectives To examine (i) accuracy and (ii) speed to assess HR using auscultation with a tap-based application during neonatal resuscitation. Research Method/Procedures The proposed study is a randomized controlled trial comparing two different approaches to accurately assess HR. The investigator will compare the routinely used Neonatal Resuscitation Program 6-sec method with a stethoscope using two different methods of auscultation [6-sec method and tap-based method (NeoTapLS, Tap4Life, Stockholm, Sweden)] to accurately assess HR immediately after birth. The investigator aim to collect the data over a period of 12 months. Two investigators in addition to the clinical team will attend the delivery of newborn infants. Immediately after birth the infant will be placed on a resuscitation trolley where a pulse oximeter will be attached to the right hand. At the same time three ECG leads will be placed on the infant's chest. Simultaneously the stethoscope will be placed by one of the investigators on the infants' chest to obtain the HR . In the alternative setup, stethoscope will be used in combination with the tap-based application. In both setups, the time needed to display a HR will be recorded for all devices. All infants will have routine HR measured using ECG, which will be used as comparison for accuracy


Recruitment information / eligibility

Status Withdrawn
Enrollment 0
Est. completion date October 31, 2021
Est. primary completion date April 30, 2021
Accepts healthy volunteers No
Gender All
Age group N/A to 5 Minutes
Eligibility Inclusion Criteria: - All newborn infants delivered in the Royal Alexandra Hospital (RAH) 22+0-41+6 weeks gestation. Exclusion Criteria: - Infants will be excluded if parents refused to consent to the study.

Study Design


Related Conditions & MeSH terms


Intervention

Device:
Heart rate assessment using the Neonatal Resuscitation Program 6-sec assessment method
Heart rate assessment using the Neonatal Resuscitation Program 6-sec assessment method At birth, the clinical team will place the stethoscope on the infant chest and calculate heart rate by listening to the heart beat for 6-sec and then compute the heart rate of the newborn infant.
Heart rate assessment using Tap-based smartphone application
At birth, the clinical team will place the stethoscope on the infant chest and calculate heart rate using a Tap-based smartphone application by tapping the screen for 3 beats at that time a heart rate will be displayed.

Locations

Country Name City State
Canada Royal Alexandra Hospital Edmonton Alberta

Sponsors (1)

Lead Sponsor Collaborator
University of Alberta

Country where clinical trial is conducted

Canada, 

References & Publications (11)

Binotti M, Cavallin F, Ingrassia PL, Pejovic NJ, Monzani A, Genoni G, Trevisanuto D. Heart rate assessment using NeoTapAdvancedSupport: a simulation study. Arch Dis Child Fetal Neonatal Ed. 2019 Jul;104(4):F440-F442. doi: 10.1136/archdischild-2018-315408. — View Citation

Duryea EL, Nelson DB, Wyckoff MH, Grant EN, Tao W, Sadana N, Chalak LF, McIntire DD, Leveno KJ. The impact of ambient operating room temperature on neonatal and maternal hypothermia and associated morbidities: a randomized controlled trial. Am J Obstet Gy — View Citation

Kamlin CO, Dawson JA, O'Donnell CP, Morley CJ, Donath SM, Sekhon J, Davis PG. Accuracy of pulse oximetry measurement of heart rate of newborn infants in the delivery room. J Pediatr. 2008 Jun;152(6):756-60. doi: 10.1016/j.jpeds.2008.01.002. Epub 2008 Mar — View Citation

Kamlin CO, O'Donnell CP, Everest NJ, Davis PG, Morley CJ. Accuracy of clinical assessment of infant heart rate in the delivery room. Resuscitation. 2006 Dec;71(3):319-21. Epub 2006 Sep 20. — View Citation

Kopotic RJ, Lindner W. Assessing high-risk infants in the delivery room with pulse oximetry. Anesth Analg. 2002 Jan;94(1 Suppl):S31-6. — View Citation

Luong DH, Cheung PY, O'Reilly M, Lee TF, Schmolzer GM. Electrocardiography vs. Auscultation to Assess Heart Rate During Cardiac Arrest With Pulseless Electrical Activity in Newborn Infants. Front Pediatr. 2018 Nov 27;6:366. doi: 10.3389/fped.2018.00366. e — View Citation

Owen CJ, Wyllie JP. Determination of heart rate in the baby at birth. Resuscitation. 2004 Feb;60(2):213-7. — View Citation

Patel S, Cheung PY, Solevåg AL, Barrington KJ, Kamlin COF, Davis PG, Schmölzer GM. Pulseless electrical activity: a misdiagnosed entity during asphyxia in newborn infants? Arch Dis Child Fetal Neonatal Ed. 2019 Mar;104(2):F215-F217. doi: 10.1136/archdisch — View Citation

Saugstad OD, Ramji S, Rootwelt T, Vento M. Response to resuscitation of the newborn: early prognostic variables. Acta Paediatr. 2005 Jul;94(7):890-5. — View Citation

Voogdt KG, Morrison AC, Wood FE, van Elburg RM, Wyllie JP. A randomised, simulated study assessing auscultation of heart rate at birth. Resuscitation. 2010 Aug;81(8):1000-3. doi: 10.1016/j.resuscitation.2010.03.021. Epub 2010 May 18. — View Citation

Wyckoff MH, Aziz K, Escobedo MB, Kapadia VS, Kattwinkel J, Perlman JM, Simon WM, Weiner GM, Zaichkin JG. Part 13: Neonatal Resuscitation: 2015 American Heart Association Guidelines Update for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care — View Citation

* Note: There are 11 references in allClick here to view all references

Outcome

Type Measure Description Time frame Safety issue
Primary Time to obtain Heart rate Time to obtain Heart rate form birth within the first 60 seconds form birth
Secondary Accuracy of heart rate assessment using either technique Accuracy of heart rate assessment using tap-based application or 6-sec method within the first 60 seconds form birth
See also
  Status Clinical Trial Phase
Completed NCT01913340 - Neonatal Erythropoietin And Therapeutic Hypothermia Outcomes in Newborn Brain Injury (NEATO) Phase 1/Phase 2
Active, not recruiting NCT04169191 - Sildenafil to Repair Brain Injury Secondary to Birth Asphyxia Phase 1
Completed NCT02858583 - SI + CC Versus 3:1 C:V Ratio During Neonatal CPR N/A
Recruiting NCT03682042 - Comparative Outcomes Related to Delivery-room Cord Milking In Low-resourced Kountries Developmental Follow Up N/A
Recruiting NCT03657394 - Comparative Outcomes Related to Delivery-room Cord Milking In Low-resourced Kountries N/A
Withdrawn NCT03681314 - Umbilical Cord Milking in Neonates Who Are Depressed at Birth-Developmental Follow Up (MIDAB-FU) N/A
Completed NCT02862925 - Introducing Fetal Scalp Stimulation as an Adjunct to Intermittent Auscultation in Low-Resource Settings. N/A
Completed NCT01751945 - Improved Accessibility of EmONC Services for Maternal and Newborn Health: a Community Based Project N/A
Terminated NCT03885492 - The Baby-Saver Kit: Clinical Testing of a Device for Neonatal Resuscitation With Intact Cord in Uganda
Completed NCT01743742 - First-day High Dose Vitamin C, E in Severe Birth Asphyxia Phase 4
Completed NCT05946681 - Sildenafil Citrate to Improve Maternal and Neonatal Outcomes in Low-resource Settings
Recruiting NCT03577054 - Development of a Mobile Application for HBB Prompt Study N/A
Active, not recruiting NCT05854745 - Comparison of Virtual Training to In-Person Training of Helping Babies Breathe in Ethiopia N/A
Not yet recruiting NCT05707962 - Neuroprotective Efficacy of Postnatal Magnesium Sulphate in Term Infants With Birth Asphyxia N/A
Completed NCT01869582 - Safer Births - Reducing Perinatal Mortality N/A
Completed NCT01350765 - Naushero Feroze Neonatal Survival Project N/A
Recruiting NCT04043299 - Effect of Intrapartum Oxygen Administration on Fetal and Early Neonatal Outcomes Phase 3
Completed NCT01865656 - A Skills and Drills Intervention for Emergency Obstetrics and Neonatal Care at First Referral Units of North Karnataka N/A
Active, not recruiting NCT04714502 - Asphyxia Associated Metabolite Biomarker Investigation 2
Recruiting NCT05275725 - Finding Solutions to Thrive After Birth Asphyxia in Africa Phase 1