Atrial Tachycardia Clinical Trial
Official title:
Switching PVC Response ''Atrial Pace'' in ST JUDE Medical or Abbott ICD (Implantable Cardioverter Defibrillator) or CRT-D (Cardiac Resynchronization Therapy) Devices to Off Mode Decreases the Burden of Atrial Tachycardia
Premature ventricular contractions (PVC) are common phenomenon and occasionally retrograde conduction from ventricle to atrium occurs and may cause pacemaker mediated tachycardia. In response certain Abbott (former St Jude Medical) pacemakers have a specific PVC response algorithm ''Atrial Pace''. In this algorithm the PVARP (Post Ventricular Atrial Refractory Period) is extended to 480ms but the initial 150ms of the PVARP is deemed absolute. If atrial sensed event occurs after absolute PVARP the PVARP terminates and atrial pace follows after 330ms alert period. Two case reports exists where patients atrial tachycardia were suspected to be induced by this algorithm. In Helsinki University Hospital an index patient with multiple atrial tachycardia episodes was recognized in late 2020 where the cause of the tachycardias was suspected to be the PVC response algorithm ''Atrial Pace''. After programming the algorithm from Atrial Pace to off mode the patient had none atrial tachycardias during 2021. After investigating all the patients with physiological ICD (Implantable Cardioverter Defibrillator) or CRT-D (Cardiac Resynchronization Therapy) device and analyzing remote monitoring transmissions from the year 2020 we found 25 patients with similar atrial tachycardia episodes possibly induced by the PVC response ''Atrial Pace''.
The device of the subjects participating to the study is interrogated and the PVC response algorithm is switched from ''Atrial Pace'' to ''Off'' mode. Subjects are also requested to fulfill the EQ-5D-3L and ICD8 questionaries before the change in the device programming and after the 12 months surveillance. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT00247351 -
Prevention of Atrial Tachycardia After a Right Atriotomy
|
N/A | |
Completed |
NCT04162249 -
High Radiofrequency Power for Faster and Safer Pulmonary Veins Isolation - a Pilot Observational Study.
|
||
Recruiting |
NCT03209583 -
ATrial Tachycardia PAcing Therapy in Congenital Heart
|
||
Recruiting |
NCT03750435 -
Non-fluoroscopy Ablation of AF/AT
|
N/A | |
Recruiting |
NCT05883631 -
RESOLVE-AF: Clinical Evaluation of the Ablacathâ„¢ Mapping Catheter and Ablamap® System Utilizing Electrographic Flow (EGF) Mapping to Resolve Extra-PV Sources of Atrial Fibrillation and Guide Ablation Therapy.
|
N/A | |
Recruiting |
NCT05434650 -
Abbott Atrial Fibrillation Post Approval Study
|
||
Completed |
NCT06335446 -
Identification, Electro-mechanical Characterisation and Ablation of Driver Regions in Persistent Atrial Fibrillation
|
||
Recruiting |
NCT05014802 -
Baseline Atrial Fibrosis Predicts Risk for Post-operative Atrial Fibrillation in Patients Undergoing Cardiac Surgery
|
||
Completed |
NCT05362656 -
AutoMatic disPERsion Tagging Function Preliminary Evaluation
|
N/A | |
Not yet recruiting |
NCT05765565 -
Comparison Between the Octaray and Pentaray Catheters in Patients Undergoing Ablation for Atrial Tachycardia.
|
N/A | |
Recruiting |
NCT05521451 -
Clinical Cohort Study - TRUST
|
||
Not yet recruiting |
NCT06327425 -
MCG for Localization of Tachyarrhythmia's Origin
|
N/A | |
Completed |
NCT03549806 -
Stanford Cardiac Invasive Electrophysiology Novel Computer Experience
|
||
Completed |
NCT02451995 -
Effectiveness of Ripple Mapping in Atrial Tachycardia Ablation
|
N/A | |
Recruiting |
NCT03816033 -
Cryotherapy Versus Radiofrequency Catheter Ablation Research Program
|
N/A | |
Completed |
NCT05802576 -
Study of Interference Between Oral Anticoagulants and Heparin During Ablation of Atrial Fibrillation (AF) or Left Atrial Tachycardia (GAD) by Catheter.
|
||
Completed |
NCT01108692 -
Strategy of Early Detection and Active Management of Supraventricular Arrhythmia With Telecardiology (SETAM)
|
N/A | |
Active, not recruiting |
NCT02374359 -
Atrial Tachycardia as a Predictor of Atrial Fibrillation, Stroke and Mortality in Cryptogenic Stroke
|
N/A | |
Completed |
NCT03151278 -
Zero Fluoroscopic Ablation Versus Conventional Fluoroscopic Ablation for Right Atrial Arrhythmias
|
N/A | |
Completed |
NCT03413150 -
Modeling of Amiodarone Effect on Heart Rate Control in Critically Ill Patients With Atrial Tachyarrhythmias
|