NCT ID: NCT02276599 Terminated - Clinical trials for Atrial Septal Defect

A Prospective Investigation of Pleth Variability Index (PVI) as a Dynamic Parameter of Fluid Responsiveness in Children

Start date: February 2015
Phase:
Study type: Observational

This study is designed to investigate the ability of pleth variability index (PVI) to non-invasively predict fluid responsiveness in mechanically ventilated children. Patients undergoing atrial septal defect (ASD) repair in the cardiac catheterization suite will be recruited for this study. These patients are ideal candidates because very few deviations will be made from standard clinical practice. All patients will already be under general anesthesia, mechanically ventilated, monitored with pulse oximetry, and provided with intravenous fluid to compensate for their nil per os (NPO) fluid deficit. The only deviation from clinical practice will include an abbreviated echocardiographic exam, application of the Masimo pulse oximeter, and measurement of CO via a thermodilution catheter by the interventional cardiologist.

NCT ID: NCT01773252 Terminated - Clinical trials for Patent Foramen Ovale

Right to Left Cardiac Shunt Detection

PFO Detection
Start date: November 2012
Phase: Phase 3
Study type: Interventional

The purpose of this study is to evaluate the sensitivity and specificity of the Cardiox Flow Detection System (FDS) in identifying an intracardiac right-to-left shunt (RLS) compared to the results of transesophageal echocardiography (TEE). RLS intracardiac shunts are associated with a number of clinically important syndromes including paradoxical thromboembolism (causing stroke or other systemic infarct), migraine headaches (particularly with aura), desaturation with obstructive sleep apnea, and decompression illness. From a research perspective, the detection of shunts in subjects with these types of syndromes is critical in helping to define the role of RLS in these disease processes. From a clinical perspective, shunt detection will be increasingly important in an era where interventional procedures for repairing cardiac defects are available for subjects determined to be at risk. The currently accepted reference standard for detection of an intra-cardiac patent foramen ovale/atrial septal defect (PFO/ASD) RLS is a transesophageal echocardiography (TEE), a procedure that is invasive, uncomfortable, and requires conscious sedation. Alternative options include transthoracic echocardiography (TTE) with injection of agitated saline (with and without Valsalva strain), a procedure that is far less sensitive than TEE due to the echocardiography imaging limitations seen in many adults. Finally, transcranial Doppler (TCD) with injection of agitated saline (with and without Valsalva strain) is a newer entrant into this arena that does not require sedation or any invasive instrumentation. The Cardiox Model 100 FDS utilizes an optical sensor positioned on the surface of the subject's skin at the scaphoid fossa of the ear. Next, a predetermined dose of an indicator dye, indocyanine green (ICG), is injected at a predetermined rate into a peripheral antecubital vein of the subject while the subject performs a breathing maneuver called a Valsalva maneuver. The exhalation by the subject into a mouthpiece connected to a pressure transducer via a flexible tubing extension, or its equivalent (ie, performing the Valsalva maneuver), is an essential step for all existing RLS detection methods. The Valsalva maneuver by the subject creates a pressure differential between the right and left sides of the heart. This Valsalva maneuver results in blood flow from the right side of the heart to the left side of the heart through an ASD, and/or causes a PFO, if present, to open, also allowing blood to flow directly from the right side to the left side of the heart without passing through the lungs (pulmonary vasculature) for oxygenation. The Earpads, including their fluorescence sensor arrays (FSA), are used to measure the relative concentration (ie, fluorescence signal level) of ICG dye in the bloodstream as a function of time. If a premature inflection or peak occurs in the ICG dye concentration level at a time point prior to the rise and fall of the concentration associated with the main bolus of indicator, then a RLS is present in the heart. The amplitude of this premature ICG dye-dilution curve (referred to as "RLS-indicator dilution curve") is used to subsequently quantify the magnitude of the right-to-left shunt by ratiometrically comparing the amplitude of this RLS indicator dilution curve to the amplitude of the main indicator dilution curve associated with that portion of the injected ICG dye that follows the normal pathway from the right side of the heart, through the lungs, and into the left side of the heart (referred to as "normal indicator dilution curve").

NCT ID: NCT01068366 Terminated - Clinical trials for Patent Foramen Ovale

Nickel Allergy With Septal Closure Devices

NASAH
Start date: February 2010
Phase: N/A
Study type: Observational

This study is for patients who have been diagnosed with either a Patent Foramen Ovale [PFO] or an Atrial Septal Defect [ASD]. These are a type of hole located in the wall that separates the top two (2) chambers of the heart. You have been recommended to receive an atrial septal occluder device [a device specifically designed to close PFOs and ASDs] implanted in your heart to close this hole. Because these devices are made of materials that contain nickel, this trial is being conducted to perform blood nickel tests on those patients already referred for an atrial septal occluder device such as yourself. The purpose of this study is to compare levels of nickel in the blood in patients receiving either the Amplatzer or the Helex devices.