Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT04472936
Other study ID # SIMPLE
Secondary ID
Status Completed
Phase N/A
First received
Last updated
Start date July 16, 2020
Est. completion date November 30, 2022

Study information

Verified date August 2023
Source Centro Medico Teknon
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

Catheter ablation is recommended as first-line therapy for most patients with typical atrial flutter. The most common approach is to create an ablation line across the cavotricuspid isthmus (CTI). Traditionally, atrial flutter ablation has been performed with a conventional approach using two catheters, an ablation catheter and a duodecapolar catheter that is placed at the level of the tricuspid annulus to confirm the CTI block. Recently, a single catheter approach has been described using the behavior of PR interval change during differential pacing over the ablation line to prove CTI block. This prospective, randomized, multicenter study analyzes the effectivity of a single catheter approach compared with conventional approach in terms of clinical outcomes.


Description:

Typical atrial flutter is a reentrant rhythm in the right atrium that is constrained anteriorly by the tricuspid annulus and posteriorly by the crista terminalis and eustachian ridge. Catheter ablation is the first-line therapy for most patients with typical atrial flutter. The most common approach is to create an ablation line across the CTI, from the tricuspid annulus to the inferior vena cava. Traditionally, atrial flutter ablation has been performed with a conventional approach using two catheters, an ablation catheter and a duodecapolar catheter that is placed at the level of the tricuspid annulus that allows to evaluate the right atrial activation sequence to confirm the CTI block. Recently, a single catheter approach has been described using the behavior of PR interval (PRI) change during differential pacing over the ablation line to prove CTI block. The PRIs is measured for three different pacing site, 5 o'clock (medial to CTI line), 7 o'clock (lateral to CTI line), and 9 o'clock position. CTI block was assumed when the PRI at 7 o'clock was >80ms longer than that at pacing sites of 5 o'clock and the PRI at 9 o'clock was shorter than the PRI at 7 o'clock. However, a direct comparison between this approach and the conventional one was not yet performed. This prospective, randomized, multicenter study analyzes the effectivity of a single catheter approach compared with conventional approach in terms of clinical outcomes. Our research hypothesis is that a single catheter approach has the possible advantages of being a faster, more efficient and cheaper procedure than the conventional approach. Moreover, as it only requires a single venous access, the risk of complications is decreased.


Recruitment information / eligibility

Status Completed
Enrollment 253
Est. completion date November 30, 2022
Est. primary completion date September 30, 2022
Accepts healthy volunteers No
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria: - Patients admitted at any of the centers to perform a CTI ablation. - Signed informed consent Exclusion Criteria: - Age < 18 years. - Pregnancy. - Impossibility to perform CTI ablation. - Impossibility to measure PRI (complete atrioventricular block). - Ablation of other cardiac arrhythmias during the same procedure. - Medical, geographical and social factors that make study participation impractical, and inability to give written informed consent. Patient's refusal to participate in the study.

Study Design


Related Conditions & MeSH terms


Intervention

Procedure:
Single catheter approach
Single venous femoral access will be obtained and the ablation will be performed similar to Group A. After the ablation line is over, we will confirm CTI block using the PRI. During atrial pacing (10 V, 1.5 ms) at a stable cycle length (range 500-700ms) from the tip of the ablation catheter with a sweep speed of 300mm/s, the ablation catheter will be placed first at 5 o'clock (medial to CTI line), then at 7 o'clock (lateral to CTI line), and finally at 9 o'clock position, and the corresponding PRIs will be measured for each pacing site. CTI block is assumed when: (i) the PRI at 7 o'clock is >80ms longer than that at pacing sites of 5, and (ii) the PRI at 9 o'clock is shorter than the PRI at 7 o'clock.
Traditional approach
Double venous femoral access will be obtained. A duodecapolar catheter will be positioned in the right atrium around the tricuspid valve annulus (TVA) to record activation sequence around the tricuspid annulus. An ablation catheter will be positioned using fluoroscopic guidance in the central CTI, 6 o'clock in a left anterior oblique view. The distal ablation electrode position will then be adjusted toward or away from the TVA, based on the ratio of atrial and ventricular electrogram amplitudes with an optimal ratio of 1:2 or 1:4 at the TVA. After the ablation catheter is positioned, it will be very slowly withdrawn during ablation toward the inferior vena cava while radiofrequency energy is applied continuously. CTI block will be evaluated after ablation by determining the right atrial activation sequence during pacing from the low lateral right atrium and coronary sinus ostium.

Locations

Country Name City State
Spain Centro Medico Teknon Barcelona
Spain Puerta del Mar University Hospital Cadiz
Spain Virgen del Rocio University Hospital Sevilla

Sponsors (1)

Lead Sponsor Collaborator
Centro Medico Teknon

Country where clinical trial is conducted

Spain, 

References & Publications (7)

Calkins H, Canby R, Weiss R, Taylor G, Wells P, Chinitz L, Milstein S, Compton S, Oleson K, Sherfesee L, Onufer J; 100W Atakr II Investigator Group. Results of catheter ablation of typical atrial flutter. Am J Cardiol. 2004 Aug 15;94(4):437-42. doi: 10.1016/j.amjcard.2004.04.058. — View Citation

Cosio FG, Lopez-Gil M, Goicolea A, Arribas F, Barroso JL. Radiofrequency ablation of the inferior vena cava-tricuspid valve isthmus in common atrial flutter. Am J Cardiol. 1993 Mar 15;71(8):705-9. doi: 10.1016/0002-9149(93)91014-9. — View Citation

Feld GK, Fleck RP, Chen PS, Boyce K, Bahnson TD, Stein JB, Calisi CM, Ibarra M. Radiofrequency catheter ablation for the treatment of human type 1 atrial flutter. Identification of a critical zone in the reentrant circuit by endocardial mapping techniques. Circulation. 1992 Oct;86(4):1233-40. doi: 10.1161/01.cir.86.4.1233. — View Citation

Lesh MD, Van Hare GF, Epstein LM, Fitzpatrick AP, Scheinman MM, Lee RJ, Kwasman MA, Grogin HR, Griffin JC. Radiofrequency catheter ablation of atrial arrhythmias. Results and mechanisms. Circulation. 1994 Mar;89(3):1074-89. doi: 10.1161/01.cir.89.3.1074. — View Citation

Madaffari A, Krisai P, Spies F, Knecht S, Schaer B, Kojic D, Kuhne M, Sticherling C, Osswald S. Ablation of typical atrial flutter guided by the paced PR interval on the surface electrocardiogram: a proof of concept study. Europace. 2019 Nov 1;21(11):1750-1754. doi: 10.1093/europace/euz208. — View Citation

Page RL, Joglar JA, Caldwell MA, Calkins H, Conti JB, Deal BJ, Estes NA III, Field ME, Goldberger ZD, Hammill SC, Indik JH, Lindsay BD, Olshansky B, Russo AM, Shen WK, Tracy CM, Al-Khatib SM. 2015 ACC/AHA/HRS guideline for the management of adult patients with supraventricular tachycardia: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm Society. Heart Rhythm. 2016 Apr;13(4):e136-221. doi: 10.1016/j.hrthm.2015.09.019. Epub 2015 Sep 25. No abstract available. — View Citation

Shah DC, Takahashi A, Jais P, Hocini M, Clementy J, Haissaguerre M. Local electrogram-based criteria of cavotricuspid isthmus block. J Cardiovasc Electrophysiol. 1999 May;10(5):662-9. doi: 10.1111/j.1540-8167.1999.tb00243.x. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary Clinical outcomes The recurrence rate of typical atrial flutter at 6 months post cavotricuspid isthmus ablation will be evaluated in both groups to determine if the single catheter approach is non-inferior when compared to traditional approach using two catheters. 6 months
Secondary Efficiency in total procedure time The total procedure time time will be measured in both groups to determine if the single catheter approach is more efficient procedure. 6 months
Secondary Efficiency in ablation time The ablation time will be measured in both groups to determine if the single catheter approach is more efficient procedure. 6 months
Secondary Efficiency in fluoroscopy time The fluoroscopy time will be measured in both groups to determine if the single catheter approach is more efficient procedure. 6 months
Secondary Complications We will compare the complication rate of both approaches. 6 months
Secondary Cost-effectiveness We will perform a cost-effectiveness analysis. 6 months
See also
  Status Clinical Trial Phase
Recruiting NCT05416086 - iCLAS™ Cryoablation System Post-Market Clinical Follow-up (PMCF) Study N/A
Terminated NCT02317029 - Comparison of Oxygen Interventions and Defibrillator Efficiency N/A
Recruiting NCT01563848 - Cryoablation in Patients With Atrial Flutter Phase 2
Completed NCT01229254 - Evaluate the Pharmacokinetics and Safety of MK-4448 in Participants With Nonvalvular Atrial Fibrillation or Atrial Flutter Phase 2
Completed NCT00839657 - Clarification of Optimal Anticoagulation Through Genetics Phase 3
Completed NCT02065388 - Pharmacogenetic Dosing of Warfarin Phase 3
Completed NCT00232232 - Use of Fish Oils to Prevent Atrial Mechanical Stunning and Atrial Remodeling Due to Atrial Arrhythmia Phase 4
Completed NCT04884100 - enHEART - Exploring Full Content of Optical Signals to Enhance Cardiac Arrhythmia Screening N/A
Completed NCT05468281 - RAFF5 Proposal: Improve the Quality and Safety of Patients Seen in the Emergency Department for Acute Atrial Fibrillation and Flutter
Completed NCT03627143 - Decreasing Hospital Admissions From the ED for AAFF N/A
Completed NCT02917538 - A Randomized Trial of Contact Force in Atrial Flutter Ablation N/A
Enrolling by invitation NCT05903313 - A Study to Evaluate Accuracy and Validity of the Chang Gung ECG Abnormality Detection Software
Recruiting NCT05755074 - Ablation of Typical Right Atrial Flutter N/A
Recruiting NCT05883631 - RESOLVE-AF: Clinical Evaluation of the Ablacath™ Mapping Catheter and Ablamap® System Utilizing Electrographic Flow (EGF) Mapping to Resolve Extra-PV Sources of Atrial Fibrillation and Guide Ablation Therapy. N/A
Recruiting NCT03272620 - Atrial Fibrillation at the Viennese University Emergency Department N/A
Completed NCT02810938 - MIFI Flutter Registry - Ablation of Atrial Flutter With IntellaTip Sensor Technology
Recruiting NCT02591875 - Atrial Flutter Ablation in a Real World Population N/A
Completed NCT02268799 - High Sensitivity Troponin T Levels Following DC Cardioversion for Atrial Fibrillation / Atrial Flutter N/A
Completed NCT01914497 - Dipole Density Mapping of Typical Atrial Flutter N/A
Active, not recruiting NCT01976507 - Use of Dabigatran Etexilate to Prevent Stroke and Thromboembolism Phase 4