Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT01857102
Other study ID # CR-5363
Secondary ID
Status Completed
Phase N/A
First received
Last updated
Start date September 2013
Est. completion date June 2014

Study information

Verified date May 2017
Source Johnson & Johnson Vision Care, Inc.
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

The purpose of this study is to determine the benefits of fitting low astigmats with soft toric contact lenses versus spherical contact lenses with regard to visual comfort, eyestrain, fitting efficiency, and visual performance.


Recruitment information / eligibility

Status Completed
Enrollment 159
Est. completion date June 2014
Est. primary completion date June 2014
Accepts healthy volunteers Accepts Healthy Volunteers
Gender All
Age group 18 Years to 45 Years
Eligibility Inclusion Criteria:

1. The subject must have read, understand, and sign the statement of informed consent and receive a fully executed copy of the Informed Consent Form.

2. The subject must appear able and willing to adhere to the instructions set forth in this protocol.

3. The subject must be between 18 years and 45 years of age (inclusive).

4. The subject must have best-corrected Snellen visual acuity of 20/30 or better in each eye.

5. If the subject has ever worn contact lenses, the subject must be a current wearer of soft spherical contact lenses for at least 5 days/week and at least 8 hours/day during the month prior to enrollment.

6. Subjective refraction must result in a vertex-corrected astigmatic contact lens prescription requiring at least -0.75 DC but not more than -1.75 DC cylindrical contact lens correction in each eye.

7. Subjective refraction must result in a vertex-corrected spherical contact lens prescription between +0.25D to +4.00D or between-0.50D to -9.00D in each eye.

8. The subject must not have the need for presbyopic correction (i.e., they must not be using as add in spectacles or wearing multifocal or monofocal contact lenses).

9. The subject must have normal eyes with no evidence of abnormality or disease that in the opinion of the investigator would contraindicate contact lens wear.

10. The subject must have access to the internet throughout the day (either desktop and/or smartphone) and be willing to answer a web-based survey within 1 hour of receiving a text message based notification throughout the day for up to 8 days, throughout the study duration.

Exclusion Criteria:

1. Self-reported current pregnancy or lactation or plans to become pregnant during the study period (subjects who report becoming pregnant during the study will be discontinued)

2. Any previous ocular or intra-ocular surgery (e.g. radial keratotomy, PRK, LASIK, etc.)

3. Any clinically meaningful slit lamp findings contraindicating contact lens wear (e.g. greater than or equal to grade 3 finding of edema, corneal neovascularization, corneal staining, conjunctival injection, blepharitis/meibomian gland dysfunction) on the FDA classification scale or any other ocular abnormality that in the opinion of the investigator may contraindicate contact lens wear.

4. Any ocular infection

5. Current use of topical ophthalmic medications other than artificial tears/rewetting drops.

6. History of binocular vision abnormality or strabismus.

7. Any infectious disease (e.g. hepatitis, tuberculosis) or a contagious immunosuppressive disease (e.g. HIV) by self-report.

8. Other active ocular disease that in the opinion of the investigator would contraindicate contact lens wear.

9. Employee of the investigational clinic (e.g. investigator, coordinator, technician)

10. Subject does not have a wearable pair of spectacles.

Study Design


Related Conditions & MeSH terms


Intervention

Device:
etafilcon A
Soft contact lens to be worn in a daily wear, daily disposable modality for one week
etafilcon A for Astigmatism
Soft contact lens to be worn by participants in a daily wear, daily disposable modality for one week.

Locations

Country Name City State
n/a

Sponsors (1)

Lead Sponsor Collaborator
Johnson & Johnson Vision Care, Inc.

Country where clinical trial is conducted

United States, 

Outcome

Type Measure Description Time frame Safety issue
Primary Objective Comfort Assessed by Electromyography(EMG) Electromyography (EMG) utilizes electrodes affixed to the skin below the eyelid, which measures activity of the orbital portion of the orbicularis oculi muscle. The orbital portion of the orbicularis oculi muscle pulls on the skin of the forehead, temple and cheek and draws it toward a point at the edge of the orbit. This part of the muscle is mainly under voluntary control, and it what is contracted during the process of squinting. The palpebral portion of this muscle closes the eyelids. The EMG reading was performed while the subject was wearing contact lenses in order to objectively assess eyestrain.The higher the EMG reading indicated the more the eyestrain. The original EMG data collected from a 40-second recording consisted of approximately 40,000 observations; the machine read about 1000 observations per second consecutively during 40-second recording. The original EMG reading was converted to a single data point and entered in the EDC for the analysis purpose. 1 week
Primary Visual Comfort The Visual comfort (diurnal fluctuation[DF]) scores were derived from the National Eye Institute Refractive Error Quality of Life (NEI-RQL) instruments- specifically the diurnal fluctuations sub-scale, by following the instruction given in the NEI-RQL-42 User Manual, Version 1.0. The NEI-RQL is a validated patient reported outcome questionnaire to assess the impact of refractive correction on vision specifically to quality of life. This survey consisted of 42 items used to develop 13 subscales: clarity of vision, expectations, near vision, far vision, diurnal fluctuations, activity limitations, glare, symptoms, dependence on correction, worry, suboptimal correction, appearance, and satisfaction with correction. An overall score is calculated by averaging the subscales. The overall scores can take on values of 0 to 100. Higher scores indicate better outcomes 1-week follow-up
See also
  Status Clinical Trial Phase
Active, not recruiting NCT04778501 - PMCF Study on Monofocal Toric IOL (PODEYE TORIC) in Asia N/A
Completed NCT04536571 - Vision Stability and Preference for Soft Toric vs. Soft Spherical Contact Lenses N/A
Completed NCT04613882 - Quantification of the Visual Benefits of Soft Toric Contact Lenses Compared to Soft Spherical Contact Lenses N/A
Completed NCT05039112 - Clinical Comparison of 2 Daily Disposable Toric Soft Contact Lenses N/A
Recruiting NCT05611294 - Contralateral Study of Topography Guided LASIK Versus Small Incision Lenticule Extraction N/A
Completed NCT05633082 - A Clinical Performance of Two Soft Toric Contact Lenses N/A
Not yet recruiting NCT05506553 - Comparison of Aspheric Toric Intraocular Lenses for Micro-monovision N/A
Not yet recruiting NCT05561296 - Astigmatism Management With Iris-registration Guided Corneal Relaxing Incisions or Toric IOLs During Cataract Surgery N/A
Completed NCT02847169 - Clinical Performance of Toric Hydrogel Contact Lenses Following One Week of Daily Wear N/A
Recruiting NCT02618018 - Clinical Evaluation of Efficacy and Stability of AT TORBI 709M 4-haptic Toric IOL in Cataract Surgery N/A
Completed NCT02555098 - A Bilateral Dispensing Clinical Trial of an Sapphire Lens Against Senofilcon A Toric for Astigmatism Lens N/A
Completed NCT02551796 - Early Changes Among FLEx, LASIK and FS-LASIK N/A
Completed NCT02550353 - Changes Between Lenticule Extraction and Femtosecond Laser-assisted Laser in Situ Keratomileusis N/A
Completed NCT02423109 - Bilateral Dispensing Study of Fanfilcon A Toric Versus Enfilcon A Toric Lenses N/A
Completed NCT02248766 - Clinical Performance of Habitual Wearers of Avaira Toric When Refitted With Clariti Toric Lenses N/A
Completed NCT01965288 - Clinical Performance of Biofinity Toric Versus Air Optix for Astigmatism N/A
Completed NCT02624791 - Evaluating and Improving Functional Driving Vision of Patients With Astigmatism N/A
Withdrawn NCT01680354 - Surgical Correction of Astigmatism N/A
Completed NCT01211535 - Subjective Comfort With Multipurpose Care Solutions in Soft Contact Lens Wearers N/A
Completed NCT01207466 - Evaluation of Two Daily Disposable Contact Lenses for Wearers With Astigmatism N/A