Artificial Limbs Clinical Trial
Official title:
Improving Physical Function and Patient-reported Outcomes Through a Quantitatively-informed Socket Design Process
This study will investigate the effects of specific standardized modifications to trans-femoral prosthetic sockets in a randomized within-subject design. This is in preparation for a subsequently planned clinical trial to validate the findings by implementing them into a fitting method for individual sockets.
Status | Recruiting |
Enrollment | 30 |
Est. completion date | September 2024 |
Est. primary completion date | June 2024 |
Accepts healthy volunteers | No |
Gender | All |
Age group | 18 Years to 80 Years |
Eligibility | Inclusion Criteria: - Transfemoral prosthesis user - 18-80 years of age - Body weight less than 125 kg - Able to walk unassisted on a treadmill Exclusion Criteria: - Pregnant females - Clinically diagnosed osteoporosis - Previous high exposure to radiation |
Country | Name | City | State |
---|---|---|---|
United States | Delatorre Orthotics & Prosthetics | Pittsburgh | Pennsylvania |
United States | University of Pittsburgh | Pittsburgh | Pennsylvania |
Lead Sponsor | Collaborator |
---|---|
University of Pittsburgh | United States Department of Defense |
United States,
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Residual Femur motion | medial-lateral and superior-inferior translation of the distal femur relative to the socket from late swing through midstance | 1 second | |
Primary | Skin strain | average and peak skin strain within each of four regions, expressed as a percentage of the gait cycle | 1 second | |
Primary | Socket pressure | measure peak pressure and area under the pressure versus time curve, expressed as a percentage of the gait cycle | 20 seconds | |
Secondary | Gait symmetry | average of the peak trunk lean, and the average peak hip flexion and extension, measured by motion capture system | 20 seconds | |
Secondary | Plantar pressure | peak plantar pressure from foot strike to midstance | 20 seconds | |
Secondary | Static displacement | distance from the most distal point of the residual femur to the inside surface of the socket under weightbearing | 1 second | |
Secondary | Tissue Stiffness | Average tissue stiffness for four regions of the residual limb | 3 seconds | |
Secondary | Trunk lean | Body angles based on markers placed on the shoulders and spine | 20 seconds | |
Secondary | Hip flexion/extension | Based on markers at greater trochanters, knee, ankle and foot. | 20 seconds | |
Secondary | Hip strength | Manual muscle testing of hip flexors and extensors | 20 seconds | |
Secondary | Hip Range of Motion | Manually measured using goniometer | 20 seconds |
Status | Clinical Trial | Phase | |
---|---|---|---|
Withdrawn |
NCT04157608 -
Energy-Harvesting Mesofluidic Impulse Prosthesis: e-MIP
|
N/A | |
Completed |
NCT04023045 -
Assist-Knee: Energy-Harvesting Knee Prosthesis
|
N/A | |
Terminated |
NCT03428815 -
Effects of Temperature Control Liner Materials on Long-Term Outcomes of Prothesis Use
|
N/A | |
Active, not recruiting |
NCT02366702 -
Kinematic, Kinetic, and Metabolic Comparison of Bilateral Transfemoral Ambulation With Passive Versus Powered Prosthetic Devices
|
||
Completed |
NCT04155762 -
Effects of Pin and Vacuum Assisted Suspension Systems
|
N/A | |
Completed |
NCT02678247 -
Functional Performance Evaluation of NU-FlexSIV Socket
|
N/A |