Clinical Trials Logo

Clinical Trial Summary

The aim of this single blinded randomised control trial study was to assess the accuracy of implantation of components and the clinical outcome and complications with the iNAV electromagnetic navigation system compared with conventional techniques. Secondary outcome measures include Patient reported outcome measures (PROMS) and rates of revision surgery up to 10 years post operatively.


Clinical Trial Description

Participants Patients were identified by members of the research team from TKA surgical waiting lists. Patients were invited to participate if they had osteoarthritis of the knee suitable for TKA, were able to provide informed consent, and were aged 18 or over. There were no specific limits imposed on the degree of preoperative coronal or sagittal deformity. Randomization Overall, 272 patients were screened between July 2007 and August 2010. Of the 272 screened patients, 14 were excluded for other medical reasons, whereas 58 participants decided that they did not want to participate in a research study. The remaining 200 patients were recruited and consented to the study giving a recruitment rate of 74%. Patients were randomized in a 1:1 ratio to either conventional TKA or navigated TKA using a web based computer-generated random number table. Randomization was based on the order of their recruitment and stratified by surgeons to prevent surgeon bias and ensure that similar numbers of patients in each groups were allocated to each surgeon. Randomization was successful in assigning equal preoperative patient demographics between the groups. Ethical Approval The study was approved by the Glasgow Royal Infirmary Local Ethics Committee and the University of Strathclyde Ethics Committee (07/S0704/6) and approved by the NHS GGC R&D department before commencement of the study. Surgical Procedure All patients received a cemented posterior stabilized NexGen LPS Flex (Zimmer, Warsaw, Indiana, USA). Participants randomized to the conventional group received a TKA implanted using standard instrumentation, whereas those randomized to the navigated group had surgery using the iNav portable EM navigation system (Zimmer GmbH, Winterthur, Switzerland and Medtronic, Minneapolis, MN, USA). The iNav EM system is imageless and uses small reference frames attached to the femur and tibia which are readily incorporated in the primary incision. There is then a process of joint registration which maps the surface anatomy of the joint. All surgeries including joint surface registration were carried out by, or under the direct supervision of, one of two knee arthroplasty surgeons. Alignment targets were similar in both groups with a neutral HKAA and the aim to implant both femur and tibial components perpendicular to this in the coronal plane. Ligament balancing was carried out using clinical assessment during the surgical procedure in both groups. In the navigated group, additional information was provided by the system with real-time feedback of the gap in mm between the femoral and tibial component and of the overall HKAA during varus and valgus stress. Primary outcome measurement Post-operative CT scans were used to determine the accuracy of implantation. CT scan analysis was conducted using Mimics 12.0 software (Materialise, Leuven, Belgium). Measurements of the femoral and tibial component position in the coronal (varus/valgus), sagittal (flexion/extension) and axial (rotational) planes were made. The overall mechanical alignment was also calculated from the addition of the femoral and tibial coronal angles. The combined component rotation was calculated from the addition of the femoral and tibial rotation angles. The rotations were measured using the methods detailed in Berger et al (1998). In the coronal plane the investigators aimed to position both femoral and tibial implants at 90° to the mechanical axis. In the sagittal plane the investigators aimed to position the femoral component with a 5° slope relative to the mechanical axis, in line with the anterior cortex of the distal femur. The tibial component was aimed to be positioned at a 7° slope, as per the manufacturer's guidelines. For femoral rotation the investigators aimed to implant the femoral component in line with the surgical trans-epicondylar axis of the femur. The reference for tibial rotation was a line from the geometric center of the tibia to the center of the tuberosity. Rotational measurements were calculated from a perpendicular line drawn from the posterior surface of the implant. As the tuberosity is 18° externally rotated, the investigators considered an 18° internal rotation of the implant to be a neutral position. (No obvious deformities of the tibia or previous fractures were noted in the study cohort that could have influenced this value.) The investigators considered the desired mechanical axis alignment to be 0° with a range of ± 3°. Patient-Reported Outcome Measures and Revisions Participants were followed up for 10 years after surgery, with clinical assessments by a blinded independent assessor; range of motion (ROM) was determined using a hand-held goniometer, and knee-specific outcome measures included the American Knee Society Score (AKSS) and Oxford Knee Scores (OKS) and the SF 36 score used as a general health measure (both physical and mental). Revision surgery was also assessed by analyzing the Scottish National Picture Archiving and Communication System. This image archiving system stores all imaging for patients undertaken in the National Health Service (NHS) in Scotland since 2008. It acts as a valuable resource for identifying patients lost to follow-up who have undergone revision surgery in other NHS hospitals in Scotland which may have not been identified. Statistics A power calculation was performed based in data provided by a randomized controlled trial using infra red optical tracking systems. Bathis et al reported 96% of patients with mechanical leg alignment within 3° of neutral using navigation compared to just 78% with conventional instrumentation . In order to detect a difference of this magnitude with a power of 90% at alpha = 0.05, the investigators would require 82 patients per group, 164 in total. As the primary outcome measure was based on post-operative CT scan the investigators anticipated a higher than average loss to follow-up for the primary outcome measure. The investigators therefore allowed an additional 25% for loss to follow-up, giving a total of 103 patients in each group. Statistical analysis was performed using SigmaPlot 11.0 (Systat Software Inc). To evaluate differences between the surgical groups either a two sample t test (normally distributed data) or a Mann Whitney test (non parametric data) was performed. A Chi Squared test was used to analysis the male: female ratio. A P value of less that 0.05 was considered significant. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05325060
Study type Interventional
Source NHS Greater Glasgow and Clyde
Contact
Status Completed
Phase N/A
Start date June 25, 2007
Completion date July 2, 2021

See also
  Status Clinical Trial Phase
Active, not recruiting NCT05666479 - CGM Monitoring in T2DM Patients Undergoing Orthopaedic Replacement Surgery
Recruiting NCT05002387 - Diagnostic Knee Needle Arthroscopy in Predicting Unicompartmental Knee Osteoarthritis N/A
Recruiting NCT06080763 - Biomechanics and Clinical Outcomes in Responders and Non-Responders
Completed NCT03008967 - A Study of Patients Undergoing Total Knee and Hip Arthroplasty at a Regional Hospital in Denmark N/A
Withdrawn NCT02255877 - ZIPS Study - Zip Incision Approximation vs. STAPLE Phase 4
Completed NCT02642731 - Kidney Biomarkers of Acute Kidney Injury in Patients With Knee Arthroplasty N/A
Completed NCT02525588 - Polyethylene Wear Study on the Triathlon Total Knee Prosthesis N/A
Completed NCT01799772 - The Feasibility of a Comprehensive Behavioral Intervention in Patient Post TKA Phase 1/Phase 2
Completed NCT02520531 - Scorpio Posterior Stabilised (PS) vs Scorpio NRG ("Energize") PS - Total Knee Arthroplasty N/A
Completed NCT03183856 - Comparison of Ambulatory and Functional Improvement by Morning Walk N/A
Completed NCT03569397 - Music Therapy Versus Control for Total Knee Arthroplasty N/A
Terminated NCT02711592 - Pharmacogenomics Information in Enhancing Post-operative Total Joint Replacement Pain Management: a Pilot Study N/A
Completed NCT03145493 - Effect of Suction Drains in Total Knee Arthroplasty With Tranexamic Acid N/A
Terminated NCT05602701 - Preoperative Prediction of Postoperative Physical Function
Recruiting NCT03570944 - Postoperative Outcomes Within an Enhanced Recovery After Surgery Protocol (POWER2)
Completed NCT02773537 - Motor-Sparing Peripheral Nerve Blockade Facilitates Mobility Post Total Knee Arthroplasty: A Randomized Controlled Trial N/A
Withdrawn NCT02553122 - The Combined Efficacy of Evicel and Tranexamic Acid on Total Knee Arthroplasty Phase 3
Recruiting NCT02385383 - An Intravenous Iron Based Protocol for Preoperative Anaemia in Hip and Knee Surgery - An Observational Study N/A
Terminated NCT02155712 - Triathlon Tritanium Knee Outcomes Study N/A
Completed NCT02121392 - Epidural Catheter With or Without Adductor Canal Nerve Block for Postoperative Analgesia Following Total Knee Arthroplasty N/A