Arthroplasty, Replacement, Knee Clinical Trial
Official title:
Knee Connect: Measuring Range of Motion and Gait Metrics After Total Knee Arthroplasty
The main goals of total knee replacement (TKR) surgery are to relieve pain and to allow patients to remain active. Sunnybrook is working with Kineris Inc.to advance a wearable device, the Knee Connect, aimed at tracking the physical recovery of patients after total knee replacements. After surgery, patients experience a gradual progression in function as their knee range of motion (ROM) increases and their gait patterns normalize. Goals for these metrics are well documented after the patient is fully recovered. However, there is a lack of detailed information available about the week by week improvements patients make in these metrics. The main objective of this study is to determine the accuracy of the Knee Connect device in quantifying the weekly improvements in ROM and gait parameters of patients recovering from surgery.
A research assistant will conduct in person data collections on 36 patients using the Kineris
wearable device. The device is an electronic goniometer connected to a smart phone
application. Patients will be recruited from the "Patient Orientation Program" (POP) at the
Sunnybrook Holland Centre. Data collection will occur preoperatively, at the end of each
physiotherapy Knee Class session, and at the three month postoperative clinic visit. The
research assistant will help fit and attach the wearable device to each patient's knee.
Patients will be asked to bend their knee (flexion and extension) while wearing the device
which will measure patients range of motion. The research assistant will also measure knee
range of motion using a handheld protractor. Afterward, patients will be asked to walk 10
steps, using any walking aids or techniques they typically use at home. There will be 15
collections per patient requiring ten minutes per session. Chart reviews will also be
conducted to determine patient reported outcomes which will be then correlated with the
functional measures.
All data will be extracted and input into an excel file. For both the ROM tests, the accuracy
of the Knee Connect device will be compared against the plastic goniometer. This will be done
by using a paired t-test and calculating interclass correlation coefficient. The data will
then be analyzed using a repeated measures ANOVA and Bonferroni post-hoc analysis to
determine differences in the variables week to week. Additionally, a regression analysis will
be used to estimate the week by week improvements in these variables.
;
Status | Clinical Trial | Phase | |
---|---|---|---|
Active, not recruiting |
NCT05666479 -
CGM Monitoring in T2DM Patients Undergoing Orthopaedic Replacement Surgery
|
||
Recruiting |
NCT05002387 -
Diagnostic Knee Needle Arthroscopy in Predicting Unicompartmental Knee Osteoarthritis
|
N/A | |
Recruiting |
NCT06080763 -
Biomechanics and Clinical Outcomes in Responders and Non-Responders
|
||
Completed |
NCT03008967 -
A Study of Patients Undergoing Total Knee and Hip Arthroplasty at a Regional Hospital in Denmark
|
N/A | |
Withdrawn |
NCT02255877 -
ZIPS Study - Zip Incision Approximation vs. STAPLE
|
Phase 4 | |
Completed |
NCT02642731 -
Kidney Biomarkers of Acute Kidney Injury in Patients With Knee Arthroplasty
|
N/A | |
Completed |
NCT02525588 -
Polyethylene Wear Study on the Triathlon Total Knee Prosthesis
|
N/A | |
Completed |
NCT01799772 -
The Feasibility of a Comprehensive Behavioral Intervention in Patient Post TKA
|
Phase 1/Phase 2 | |
Completed |
NCT02520531 -
Scorpio Posterior Stabilised (PS) vs Scorpio NRG ("Energize") PS - Total Knee Arthroplasty
|
N/A | |
Completed |
NCT03183856 -
Comparison of Ambulatory and Functional Improvement by Morning Walk
|
N/A | |
Completed |
NCT03569397 -
Music Therapy Versus Control for Total Knee Arthroplasty
|
N/A | |
Terminated |
NCT02711592 -
Pharmacogenomics Information in Enhancing Post-operative Total Joint Replacement Pain Management: a Pilot Study
|
N/A | |
Completed |
NCT03145493 -
Effect of Suction Drains in Total Knee Arthroplasty With Tranexamic Acid
|
N/A | |
Terminated |
NCT05602701 -
Preoperative Prediction of Postoperative Physical Function
|
||
Recruiting |
NCT03570944 -
Postoperative Outcomes Within an Enhanced Recovery After Surgery Protocol (POWER2)
|
||
Completed |
NCT02773537 -
Motor-Sparing Peripheral Nerve Blockade Facilitates Mobility Post Total Knee Arthroplasty: A Randomized Controlled Trial
|
N/A | |
Withdrawn |
NCT02553122 -
The Combined Efficacy of Evicel and Tranexamic Acid on Total Knee Arthroplasty
|
Phase 3 | |
Recruiting |
NCT02385383 -
An Intravenous Iron Based Protocol for Preoperative Anaemia in Hip and Knee Surgery - An Observational Study
|
N/A | |
Completed |
NCT02121392 -
Epidural Catheter With or Without Adductor Canal Nerve Block for Postoperative Analgesia Following Total Knee Arthroplasty
|
N/A | |
Terminated |
NCT02155712 -
Triathlon Tritanium Knee Outcomes Study
|
N/A |