Clinical Trial Summary

The purpose of this study is determine the effect on novel pressure-regulating tourniquet use on pain, functional recovery, sleep and total blood loss following total knee arthroplasty.


Clinical Trial Description

Functional recovery after total knee arthroplasty (TKA) has seen dramatic improvement over the past 20 years through advances in surgical technique, implant design, perioperative pain management strategies, and physical therapy protocols. Tourniquet use during TKA, however, remains controversial due to conflicting reports in the literature on these benefits and risks of its use. Reported advantages of tourniquet use include improved visualization of the surgical field and decreased intraoperative blood loss. Reported disadvantages of tourniquet use include increased postoperative pain and slower functional recovery as a direct result of the pressure of the tourniquet on the thigh during the procedure. Traditionally with tourniquet use during TKA, the limb is exsanguinated and the tourniquet is raised to a fixed, pressure at the beginning of the case, typically 250mmHg to 350mmHg, and let down after closure. A novel tourniquet design that adjusts the tourniquet pressure in real-time based on intraoperative patient blood pressure measurements. This design may allow for the tourniquet to be inflated at a lower mean pressure while still maintaining efficacy. A prospective study comparing total blood loss, pain and functional recovery after TKA using this novel tourniquet design, design (Zimmer A.T.S.® 4000TS Automatic Tourniquet System, with disposable contour cuffs) and TKA without tourniquet would further the current literature. Total blood loss will be calculated by previously validated methods. Pain and functional recovery will be closely monitored throughout the postoperative period using a patient wearable activity tracker (FitBit Inspire HR) and a smartphone-based patient engagement platform with integrated digital surveys paired with smart-brace based home PT assessments (FocusMotion).Pain and functional recovery will be closely monitored throughout the postoperative period using a patient wearable activity tracker (FitBit Inspire HR) and a smartphone-based patient engagement platform with integrated digital surveys paired with smart-brace based home PT assessments (FocusMotion). Applying this technology to the proposed study can help identify problematic pain that is not appreciable during admission; given the fact that markers of inflammation and myocyte damage increase over time until at least post-operative day 3, it is possible that TKAs performed under tourniquet may have pain and narcotic requirements not appreciated with short-stay admissions . The proposed study will further the literature on pain and narcotic use in the early time period after TKA, and will help identify if tourniquet has an effect on these variables. Furthermore, sleep quality is a component of functional recovery and is correlated with pain. Knee osteoarthritis affects general quality of life by increasing sleep disturbance and nighttime wakening, and this is correlated with the pre-operative radiographic severity of disease. Sleep quality is affected in the immediate post-operative period after TKA as well, but improves by 3-6 months post-operatively . The proposed study would be the largest prospective study investigating the effect of TKA on pain and sleep quality, as well as being the first to investigate tourniquet use as a factor affecting sleep quality and pain. The proposed study would be the first to collect both subjective and objective data on the subject, using validated survey measurements as well as the data collected by the Fitbit Inspire HR device. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04923724
Study type Interventional
Source Washington University School of Medicine
Contact
Status Completed
Phase N/A
Start date November 1, 2020
Completion date November 30, 2023

See also
  Status Clinical Trial Phase
Recruiting NCT06061367 - Muscles Strength and Gait Parameteres After TKA
Completed NCT04565093 - Efficacy of iPACK After Unilateral TKA N/A
Not yet recruiting NCT05290818 - Total Versus Robotic Assisted Unicompartmental Knee Replacement N/A
Terminated NCT03253224 - Magnesium and Postoperative Pain Phase 4
Completed NCT04956393 - The SOAR (Stop OsteoARthritis) Program Proof-of-Concept Study N/A
Not yet recruiting NCT04479462 - The Establishment of Total Joint Arthroplasty Registry Database
Terminated NCT04712019 - Evaluating Edema and Range of Motion Using Negative Pressure Therapy vs. Standard Surgical Dressing in Bilateral TKA N/A
Completed NCT04648072 - How Does the Addition of Adductor Canal Block to Local Infiltration Affect Recovery in Patients Undergoing Total Knee Arthroplasty? A Feasibility Study. N/A
Withdrawn NCT03704558 - Preoperative Radiographic Evaluation of Medial Tibiofemoral Knee Osteoarthritis
Not yet recruiting NCT06024161 - Weight Change and the Risk of Chronic Pain Following Hip and Knee Arthroplasties
Not yet recruiting NCT05900791 - Persistent Pain After Knee Replacement
Completed NCT06196359 - Assessing Function and Pain After Total Knee Arthroplasty With Combined Femoral and Popliteal Nerve Block N/A
Completed NCT05065775 - Bioavailability of Intranasal Dexmedetomidine Phase 4
Completed NCT03540667 - Study of Hip and Knee Arthroplasty in South Africa
Completed NCT04388111 - Intraosseous Morphine in Primary TKA Phase 4
Completed NCT04441112 - Intraarticular Injections of the Hip and Knee With Triamcinolone Versus Ketorolac: A Randomized Controlled Trial Phase 2/Phase 3
Not yet recruiting NCT03874468 - Prevalence of Coronal Femoral Bowing in the Egyptian Arthritic Knee
Not yet recruiting NCT05760534 - Ideal Dosage for Sedation of Obese Patients Undergoing Knee or Hip Arthroplasty Under Spinal Anesthesia Phase 4
Completed NCT04814706 - Gastric Volume in Elderly Patients Undergoing Staged Bilateral Total Knee Arthroplasty
Not yet recruiting NCT06264999 - Robotic Assisted Knee Arthroplasty - Retain the Anterior Cruciate Ligament or Not N/A