Arrhythmias, Cardiac Clinical Trial
Official title:
The TIGHT-K STUDY. Prevention of Dysrhythmias on the Cardiac Intensive Care Unit - Does Maintenance of High-normal Serum Potassium Levels Matter
The purpose of this study is to determine whether a strategy of maintaining serum potassium levels at ≥3.6 mEq/L is non-inferior to a strategy of usual treatment (≥4.5 mEq/L) on the occurrence of new onset atrial fibrillation after cardiac surgery (AFACS) in patients undergoing isolated coronary artery bypass graft (CABG) surgery.
At least one in three patients is affected by atrial fibrillation after cardiac surgery(AFACS), with most episodes occurring in the first five postoperative days. AF occurrence is associated with increased morbidity, short and long-term mortality, intensive care unit (ICU) and hospital stay and cost of care. Persistence of these associations after adjustment for potential confounding factors suggests that they may be causal. The incidence and prevalence of AF and its associated costs are expected to increase as the surgical population ages. Extensive effort is undertaken to prevent AF after cardiac surgery from occurring, but clinical practice in this area is highly variable and the evidence base for most interventions is sparse. Potassium plays an important role in cardiac electrophysiology. Serum potassium concentrations ([K+]) are commonly low following cardiac surgery, and appear marginally lower in those suffering atrial arrhythmias in non-surgical cohorts. Despite an absence of proof that this association is causal, efforts to maintain serum [K+] in the 'high-normal' range (≥ 4.5 mEq/L), as opposed to just intervening if potassium drops below its lower 'normal' threshold (<3.6 mEq/L), are considered 'routine practice' for AF prevention in post-surgical patients in many centres across the world. From the (unpublished) data from our Tight-K Feasibility Study, all 160 patients would have required at least one dose of potassium to supplement their levels to this high-normal range and 45.5% of all serum [K+] measurements were below 4.5mEq/L at some point. Data from the same pilot study show a median number of potassium doses given in the 'tight' group (high-normal serum potassium target) of seven, compared to a median of one, with most patients not receiving any potassium supplementation at all, in the 'relaxed' group. This demonstrated for the first time ever, that the practice does achieve a separation in serum potassium levels between the two groups, so the protocol is indeed effective in achieving higher serum potassium levels. The efficacy of the practice of maintaining high-normal serum potassium levels for the prevention of AF after cardiac surgery, however, remains unproven and data supporting it are extremely limited, being derived from observational studies rather than randomised trials. Indeed, no data exist to demonstrate that maintaining a high-normal potassium level is beneficial in these circumstances, or that aggressive replenishment of potassium in these patients improves outcome. Meanwhile, potassium supplementation may cause discomfort or harm. Routine central venous potassium administration in the early post-operative period, when oral supplementation is not possible, is time-consuming, costly and associated with clinical risk: rapid infusion can prove fatal, and leaving central venous catheters in situ for the sole purpose of potassium replacement increases infection risk. Oral replacement (when feasible) is commonly associated with profound nausea and gastrointestinal side effects, and is very poorly tolerated by patients. The annual costs of intravenous potassium exceed those for other drugs in many cardiac surgical units due to the large quantities administered. Nursing time (e.g. for drug checks and administration) will add to this cost. The routine maintenance of serum [K+] ≥ 4.5 mEq/L is a costly practice of unproven efficacy that is unpleasant and may be hazardous for patients. The investigators shall address this issue, performing the first appropriately powered non-inferiority multicentre randomised trial of potassium supplementation in patients undergoing coronary artery bypass surgery. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT03079726 -
Use of Device Data to Predict Frailty in Individuals
|
||
Recruiting |
NCT06014996 -
Comparison of PFA vs. RFA in Patients With Symptomatic Paroxysmal Atrial Fibrillation.
|
N/A | |
Recruiting |
NCT04092985 -
Smart Watch iECG for the Detection of Cardiac Arrhythmias
|
||
Completed |
NCT05404789 -
Tolerance of Centrifuge-induced Acceleration in Subjects With Diabetes Mellitus and Cardiac Arrhythmia
|
N/A | |
Recruiting |
NCT04554160 -
Arrhythmias in Pulmonary Hypertension Assessed by Continuous Long-term Cardiac Monitoring
|
||
Recruiting |
NCT04471584 -
Comparative Analysis in Detection of Atrial Arrhythmia and ECG Quality in Three Different Insertable Cardiac Monitors
|
N/A | |
Recruiting |
NCT02906189 -
Safety of Magnetic Resonance Imaging in Non-MRI Conditional Pacemakers and ICD Devices
|
N/A | |
Completed |
NCT02550340 -
Munich Study for Beer Related ECG Change Workup
|
N/A | |
Completed |
NCT02466633 -
Effect of Monitoring System Design on Response Time to Cardiac Arrhythmias
|
N/A | |
Completed |
NCT01871090 -
Remote Device Interrogation In The Emergency Department
|
N/A | |
Completed |
NCT04884100 -
enHEART - Exploring Full Content of Optical Signals to Enhance Cardiac Arrhythmia Screening
|
N/A | |
Withdrawn |
NCT04556240 -
RECORD-VP: Real-time Evaluation of Cardiac Outpatient Recording Device With VitalPatch RTM
|
||
Active, not recruiting |
NCT05481359 -
AF-FLOW Registry: This Study is to Evaluate Ablamap Software in Patients Undergoing Ablation for Atrial Fibrillation.
|
||
Recruiting |
NCT05047835 -
Comparison of Prone Position and Standard Electrocardiogram in COVID-19 Patients
|
||
Not yet recruiting |
NCT05974306 -
Evaluation of a Proactive Clinical Management and Early Diagnosis of Arrhythmias in Patients With Heart Failure and Non Severely Reduced Left Ventricular Function Through a Telemonitoring System
|
N/A | |
Not yet recruiting |
NCT05957315 -
Mobile Cardiac Outpatient Telemetry for Unexplained Syncope
|
N/A | |
Completed |
NCT06260670 -
FLOW EVAL-AF: FLOW Mapping Electrogram VALidation in Patients With Persistent Atrial Fibrillation
|
N/A | |
Active, not recruiting |
NCT04876963 -
HOLT-ED: Holter-monitoring in End-stage Renal Disease
|
||
Completed |
NCT04943354 -
Associations of Combinations of Single-nucleotide Polymorphisms in Women With Premature Ovarian Failure
|
N/A | |
Recruiting |
NCT03857711 -
Randomized Clinical Trial PULVAB (Prophylactic Pulmonary Veins Ablation)
|
N/A |