Clinical Trials Logo

Clinical Trial Summary

The covered endovascular reconstruction of aortic bifurcation (CERAB) technique was described l in 2013 to reconstruct the aortic bifurcation in a more anatomical and physiological way. With the use of this technique, a covered stent is expanded 15 to 20 mm above the aortic bifurcation and this stent is proximally adapted to the aortic wall with a larger balloon, thereby creating a cone-shaped stent. Two iliac covered stents are then placed in the distal conic segment and simultaneously inflated, making a tight connection with the aortic stent, as if they were molded together, thus simulating a new bifurcation. This minimal invasive endovascular technique using covered stents, was developed in order to optimize endovascular mimicking the anatomical configuration of the aortic bifurcation and in an attempt to overcome the disadvantages of kissing stents influenced by geometric factors such as radial mismatch, protrusion mismatch and stent conformation. The use of BeGraft (balloon-expandalbe covered stent) and Solaris (self-expandable covered stent) fro this technique is revised.


Clinical Trial Description

The covered endovascular reconstruction of aortic bifurcation (CERAB) technique was described l in 2013 to reconstruct the aortic bifurcation in a more anatomical and physiological way. With the use of this technique, a covered stent is expanded 15 to 20 mm above the aortic bifurcation and this stent is proximally adapted to the aortic wall with a larger balloon, thereby creating a cone-shaped stent. Two iliac covered stents are then placed in the distal conic segment and simultaneously inflated, making a tight connection with the aortic stent, as if they were molded together, thus simulating a new bifurcation. This minimal invasive endovascular technique using covered stents, was developed in order to optimize endovascular mimicking the anatomical configuration of the aortic bifurcation and in an attempt to overcome the disadvantages of kissing stents influenced by geometric factors such as radial mismatch, protrusion mismatch and stent conformation. The use of BeGraft (balloon-expandalbe covered stent) and Solaris (self-expandable covered stent) fro this technique is revised. A retrospective study included patients that underwent endovascular treatment of atherosclerotic steno-occlusive aorto-iliac lesions between January 2020 and June 2023. The study, which received no financial support from industry, was performed in agreement with the Declaration of Helsinki and was approved by our institutional review boards. In accordance with institutional and local regulatory policies, this retrospective review of de-identified procedural and follow-up data was exempt from informed consent. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT06012123
Study type Observational [Patient Registry]
Source Vascular Investigation Network Spanish Society for Angiology and Vascular Surgery
Contact
Status Completed
Phase
Start date January 1, 2023
Completion date August 15, 2023

See also
  Status Clinical Trial Phase
Active, not recruiting NCT04023370 - Evaluation of the Efficacy and Safety of the Application of BeGraft Peripheral Stent Graft System N/A
Not yet recruiting NCT04175197 - LegDeb2 Global Registry for Use of Legflow in Peripheral Arteries
Completed NCT00896337 - EPIC Nitinol Stent System in the Treatment of Atherosclerotic Lesions in Iliac Arteries Phase 3
Active, not recruiting NCT04299906 - SOLARIS Peripheral PMCF Trial N/A
Recruiting NCT03687983 - Safety and Efficacy Study of GoldenFlow Peripheral Stent System N/A
Not yet recruiting NCT05229250 - NIRS and Exercise Intensity in Patients With FLIA
Not yet recruiting NCT05377775 - Mesh Stents Study in ILIAC Complex Lesions (IMS-Study) N/A
Not yet recruiting NCT04545281 - Physician-Initiated PMCF Trial Investigating the Solaris Vascular Stent Graft for the Treatment of Iliac Lesions Phase 4
Recruiting NCT04714268 - Comparison of Aorto-iliac Endovascular Interventions With and Without the EndoNaut Workstation
Recruiting NCT02793492 - Misago® RX Self-expanding Peripheral Stent for Common and/or External Iliac Artery N/A
Enrolling by invitation NCT05117515 - Retrospective Study of the Uni-Graft® K DV Patch in the Clinical Routine
Completed NCT04343196 - Digital Variance Angiography in Diagnostic Angiographies for Effective Radiation Dose Reduction N/A
Completed NCT03844724 - Drug-eluting PTA Balloon Dilatation Catheter in the Treatment of Peripheral Artery Stenosis or Occlusion N/A