Aortic Valve Stenosis Clinical Trial
Official title:
CT-evaluation of Coronary Ostia Height After Surgical Aortic Valve Replacement.
The goal of this interventional, single-center study is to demonstrate if there is a change in the coronary ostia height after surgical aortic valve replacement and if it depends on the type of prosthesis or surgical technique used. The study involves patients undergoing elective surgical aortic valve replacement with a bioprosthesis. Participants enrolled will undergo a CT scan before and after surgery (at least 90 days after surgery) to analyze coronary ostia height.
Aortic valve stenosis is the most frequent heart valve disease in the adult population. The development of biological prostheses with slower valve degeneration and easier antithrombotic management and changes in the indications for the treatment of this valve disease, have allowed a reduction in the age in which such prostheses are implanted thus leading to a greater use of biological prostheses rather than mechanical ones. In the next few years this will cause a higher rate of structural valve degeneration resulting in stenosis and/or insufficiency. In patients considered to be at high surgical risk, the transcatheter implantation of a valve-in-valve (VIV) represents a valid alternative to standard surgery, except for coronary obstruction which appears more frequent in VIV procedures, especially in patients receiving VIV after surgical aortic valve replacement. The risk factors mainly associated with this complication are represented by the type of implanted prostheses and the anatomical relationship between the coronary ostia and the expected final position of the cusps of the bioprostheses transcatheter-implanted.Recent studies have demonstrated how coronary height seems to be significantly reduced in case of surgical aortic valve replacement with a supra-annular technique, as occurs in our center. Aim of this interventional, single-center study is to demonstrate whether there is a change in the coronary ostia height after surgical aortic valve replacement and whether it possibly depends on the type of prosthesis. All patients undergoing elective aortic valve replacement surgery at our institution who meet the inclusion criteria for the study will be contacted to perform a postoperative CT scan at least 90 days after surgery. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT03186339 -
Validation of the "TASQ" in Patients Undergoing SAVR or TF-TAVI
|
||
Recruiting |
NCT03549559 -
Imaging Histone Deacetylase in the Heart
|
N/A | |
Terminated |
NCT02854319 -
REpositionable Percutaneous Replacement of NatIve StEnotic Aortic Valve Through Implantation of LOTUS EDGE Valve System
|
N/A | |
Recruiting |
NCT05601453 -
The ReTAVI Prospective Observational Registry
|
||
Withdrawn |
NCT05481814 -
CPX in Paradoxical Low Flow Aortic Stenosis
|
||
Completed |
NCT02241109 -
Predicting Aortic Stenosis Progression by Measuring Serum Calcification Propensity
|
N/A | |
Completed |
NCT01700439 -
Surgical Treatment of Aortic Stenosis With a Next Generation, Rapid Deployment Surgical Aortic Valve
|
N/A | |
Recruiting |
NCT04429035 -
SLOW-Slower Progress of caLcificatiOn With Vitamin K2
|
N/A | |
Completed |
NCT04103931 -
Impact of a Patient Decision Aid for Treatment of Aortic Stenosis
|
N/A | |
Completed |
NCT03950440 -
Assessing the Incidence of Postoperative Delirium Following Aortic Valve Replacement
|
||
Active, not recruiting |
NCT02661451 -
Transcatheter Aortic Valve Replacement to UNload the Left Ventricle in Patients With ADvanced Heart Failure (TAVR UNLOAD)
|
N/A | |
Completed |
NCT02847546 -
Evaluation of the BARD® True™ Flow Valvuloplasty Perfusion Catheter for Aortic Valve Dilatation
|
N/A | |
Completed |
NCT02792452 -
Clinical Value of Stress Echocardiography in Moderate Aortic Stenosis
|
||
Completed |
NCT02758964 -
Evaluation of Cerebral Thrombembolism After TAVR
|
||
Not yet recruiting |
NCT02541877 -
Sizing-sTrategy of Bicuspid AoRtic Valve Stenosis With Transcatheter Self-expandable Valve
|
Phase 3 | |
Not yet recruiting |
NCT02536703 -
Safety and Efficacy of Lotus Valve For TAVI In Patients With Severe Aortic Stenosis In Chinese Population
|
Phase 3 | |
Completed |
NCT02249000 -
BIOVALVE - I / II Clincial Investigation
|
N/A | |
Not yet recruiting |
NCT02221921 -
Safety and Efficacy Study of MicroPort's Transcatheter Aortic Valve and Delivery System for TAVI
|
N/A | |
Active, not recruiting |
NCT02080299 -
Protection by Remote Ischemic Preconditioning During Transcatheter Aortic Valve Implantation
|
Phase 2 | |
Terminated |
NCT01939678 -
Characterization and Role of Mutations in Sodium-phosphate Cotransporters in Patients With Calcific Aortic Valve Disease
|