Aortic Valve Stenosis Clinical Trial
Official title:
Balloon-Expandable Versus Self-expanding Transcatheter Heart Valve for Treatment of Symptomatic Native Aortic Valve Stenosis
Over the last years, several randomized studies comparing transcatheter aortic valve implantation (TAVI) to surgical aortic valve replacement (SAVR) have established TAVI as a treatment option in symptomatic patients with aortic stenosis (AS) (1,2,3). Most transcatheter heart valves (THV) available are designed on either a balloon-expandable (BE) or a self-expanding (SE) concept. Despite major differences, both designs are recommended to be used indifferently in most of the clinical situations and a significant number of centers only implant one of this two THV design. It remains unclear however, whether these 2 very different THV concepts are achieving similar or different clinical outcomes and could be considered a single "Class" of device. While there is an urgent clinical need to clarify this issue in an exponentially growing therapeutic field, to date no large randomized study powered to compare the 2 THV designs on individual endpoints has been conducted or initiated. Recently, two large-scale French registry-based propensity matched analyses, including more than 30,000 patients, have reported a higher 90 days and 1-year mortality with the use of SE as compared to BE-valve (4,5). However, as the propensity-score matching-approach cannot rule out residual confounders, and as some of the most recent THV iterations were not part of the investigation, there is an urgent need to conduct a randomized trial sufficiently powered to compare head-to-head the latest generation of SE and BE-valve on all-cause mortality. In addition, two small randomized studies have recently showed the inferiority of a new SE-valve compared to BE-valve and SE-THV (SCOPE1 trial, J Lanz. Lancet. 2019 Nov 2;394(10209):1619-1628. and SCOPE 2 trial, Circulation in press), thus further questioning wether THV should be considered as a single "Class" regardless the THV design. The objective of the present randomized clinical investigation will be to evaluate the impact of THV design (SE vs BE) on the risk of all-cause mortality at 90 days and 1 year. The present clinical investigation will the first randomized clinical investigation to compare head to head the benefit of BE-valve over SE-valve on total mortality at 90 days and 1-year using a superiority design. Previous head-to-head studies included only a small number of patients, non-inferiority designs and combined endpoints. This clinical investigation will be the first to generate sufficient evidences to change clinical practice and international guidelines to clarify whether one THV design is superior (or not) to the other one (BE vs SE-valve). The result of the clinical investigation is key for clinicians indicating the treatment and for the patients receiving the treatment
n/a
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT03186339 -
Validation of the "TASQ" in Patients Undergoing SAVR or TF-TAVI
|
||
Recruiting |
NCT03549559 -
Imaging Histone Deacetylase in the Heart
|
N/A | |
Terminated |
NCT02854319 -
REpositionable Percutaneous Replacement of NatIve StEnotic Aortic Valve Through Implantation of LOTUS EDGE Valve System
|
N/A | |
Recruiting |
NCT05601453 -
The ReTAVI Prospective Observational Registry
|
||
Withdrawn |
NCT05481814 -
CPX in Paradoxical Low Flow Aortic Stenosis
|
||
Completed |
NCT02241109 -
Predicting Aortic Stenosis Progression by Measuring Serum Calcification Propensity
|
N/A | |
Completed |
NCT01700439 -
Surgical Treatment of Aortic Stenosis With a Next Generation, Rapid Deployment Surgical Aortic Valve
|
N/A | |
Recruiting |
NCT04429035 -
SLOW-Slower Progress of caLcificatiOn With Vitamin K2
|
N/A | |
Completed |
NCT04103931 -
Impact of a Patient Decision Aid for Treatment of Aortic Stenosis
|
N/A | |
Completed |
NCT03950440 -
Assessing the Incidence of Postoperative Delirium Following Aortic Valve Replacement
|
||
Active, not recruiting |
NCT02661451 -
Transcatheter Aortic Valve Replacement to UNload the Left Ventricle in Patients With ADvanced Heart Failure (TAVR UNLOAD)
|
N/A | |
Completed |
NCT02758964 -
Evaluation of Cerebral Thrombembolism After TAVR
|
||
Completed |
NCT02847546 -
Evaluation of the BARD® True™ Flow Valvuloplasty Perfusion Catheter for Aortic Valve Dilatation
|
N/A | |
Completed |
NCT02792452 -
Clinical Value of Stress Echocardiography in Moderate Aortic Stenosis
|
||
Not yet recruiting |
NCT02541877 -
Sizing-sTrategy of Bicuspid AoRtic Valve Stenosis With Transcatheter Self-expandable Valve
|
Phase 3 | |
Not yet recruiting |
NCT02536703 -
Safety and Efficacy of Lotus Valve For TAVI In Patients With Severe Aortic Stenosis In Chinese Population
|
Phase 3 | |
Completed |
NCT02249000 -
BIOVALVE - I / II Clincial Investigation
|
N/A | |
Not yet recruiting |
NCT02221921 -
Safety and Efficacy Study of MicroPort's Transcatheter Aortic Valve and Delivery System for TAVI
|
N/A | |
Active, not recruiting |
NCT02080299 -
Protection by Remote Ischemic Preconditioning During Transcatheter Aortic Valve Implantation
|
Phase 2 | |
Terminated |
NCT01939678 -
Characterization and Role of Mutations in Sodium-phosphate Cotransporters in Patients With Calcific Aortic Valve Disease
|