Clinical Trials Logo

Clinical Trial Summary

Transcatheter aortic valve implantation (TAVI) is recommended for patients with severe aortic stenosis (AS) at high to intermediate surgical risk. Despite similar mortality rates compared to surgical aortic valve replacement (SAVR) in this setting, the rate para-valvular leak (PVL) remains higher and has been associated to higher mortality even at mild degree. This is one of the major concerns to extend TAVI to low surgical risk, although the favorable results from PARTNER 3. The presence of moderate to severe PVL after TAVI is associated to a 2- and 3- fold increase in the mortality rate at 30-day and 1-year follow-up, respectively (24-29). Prosthesis-patient mismatch (PPM) adversely affects functional improvement and exercise tolerance, left ventricular (LV) mass regression, and late structural valve deterioration. Many studies have previously investigated PPM after surgical AVR suggesting the presence of this problem in more than 40% of the surgically treated patients. This rate was significantly lower with the balloon-expandable Sapien (Edwards Lifesciences, Irvine, California), with PPM that varied from 8% to 18%, but in both cases (patients harboring TAVI and those with SAVR) the mortality rate was higher in the presence of PPM. Under the hypothesis that there are differences in terms of transvalvular gradients and residual para-valvular leak amongst different balloon-expandable TAVI devices available in the market, the aim of the MATCH-BALL study is to compare the hemodynamic performance of two balloon-expandable TAVI devices, Sapien 3 (Edwards Lifesciences, Irvine, CA, USA) and Myval (Meril Life Sciences Pvt. Ltd., India).


Clinical Trial Description

n/a


Study Design


Related Conditions & MeSH terms


NCT number NCT04548726
Study type Observational
Source Hospital Clínico Universitario de Valladolid
Contact
Status Completed
Phase
Start date June 1, 2018
Completion date September 30, 2020

See also
  Status Clinical Trial Phase
Completed NCT03186339 - Validation of the "TASQ" in Patients Undergoing SAVR or TF-TAVI
Recruiting NCT03549559 - Imaging Histone Deacetylase in the Heart N/A
Terminated NCT02854319 - REpositionable Percutaneous Replacement of NatIve StEnotic Aortic Valve Through Implantation of LOTUS EDGE Valve System N/A
Recruiting NCT05601453 - The ReTAVI Prospective Observational Registry
Withdrawn NCT05481814 - CPX in Paradoxical Low Flow Aortic Stenosis
Completed NCT02241109 - Predicting Aortic Stenosis Progression by Measuring Serum Calcification Propensity N/A
Completed NCT01700439 - Surgical Treatment of Aortic Stenosis With a Next Generation, Rapid Deployment Surgical Aortic Valve N/A
Recruiting NCT04429035 - SLOW-Slower Progress of caLcificatiOn With Vitamin K2 N/A
Completed NCT04103931 - Impact of a Patient Decision Aid for Treatment of Aortic Stenosis N/A
Completed NCT03950440 - Assessing the Incidence of Postoperative Delirium Following Aortic Valve Replacement
Active, not recruiting NCT02661451 - Transcatheter Aortic Valve Replacement to UNload the Left Ventricle in Patients With ADvanced Heart Failure (TAVR UNLOAD) N/A
Completed NCT02758964 - Evaluation of Cerebral Thrombembolism After TAVR
Completed NCT02792452 - Clinical Value of Stress Echocardiography in Moderate Aortic Stenosis
Completed NCT02847546 - Evaluation of the BARD® True™ Flow Valvuloplasty Perfusion Catheter for Aortic Valve Dilatation N/A
Not yet recruiting NCT02541877 - Sizing-sTrategy of Bicuspid AoRtic Valve Stenosis With Transcatheter Self-expandable Valve Phase 3
Not yet recruiting NCT02536703 - Safety and Efficacy of Lotus Valve For TAVI In Patients With Severe Aortic Stenosis In Chinese Population Phase 3
Completed NCT02249000 - BIOVALVE - I / II Clincial Investigation N/A
Not yet recruiting NCT02221921 - Safety and Efficacy Study of MicroPort's Transcatheter Aortic Valve and Delivery System for TAVI N/A
Active, not recruiting NCT02080299 - Protection by Remote Ischemic Preconditioning During Transcatheter Aortic Valve Implantation Phase 2
Terminated NCT01939678 - Characterization and Role of Mutations in Sodium-phosphate Cotransporters in Patients With Calcific Aortic Valve Disease